Your browser doesn't support javascript.
loading
Push-out bond strength of MTA HP, a new high-plasticity calcium silicate-based cement
Silva, Emmanuel Jnl; Carvalho, Nancy Kudsi; Zanon, Mayara; Senna, Plínio Mendes; De-Deus, Gustavo; Zuolo, Mário Luis; Zaia, Alexandre Augusto.
Afiliação
  • Silva, Emmanuel Jnl; Universidade do Grande Rio. School of Dentistry. Department of Endodontics. Rio de Janeiro. BR
  • Carvalho, Nancy Kudsi; Universidade do Grande Rio. School of Dentistry. Department of Endodontics. Rio de Janeiro. BR
  • Zanon, Mayara; Universidade do Grande Rio. School of Dentistry. Department of Endodontics. Rio de Janeiro. BR
  • Senna, Plínio Mendes; Universidade do Grande Rio. School of Dentistry. Department of Endodontics. Rio de Janeiro. BR
  • De-Deus, Gustavo; Universidade do Grande Rio. School of Dentistry. Department of Endodontics. Rio de Janeiro. BR
  • Zuolo, Mário Luis; Universidade Estadual de Campinas. Piracicaba School of Dentistry. Department of Endodontics. Piracicaba. BR
  • Zaia, Alexandre Augusto; Universidade Estadual de Campinas. Piracicaba School of Dentistry. Department of Endodontics. Piracicaba. BR
Braz. oral res. (Online) ; 30(1): e84, 2016. graf
Artigo em Inglês | LILACS | ID: biblio-952007
Biblioteca responsável: BR1.1
ABSTRACT
Abstract This study was designed to investigate the resistance to dislodgment provided by MTA HP, a new high-plasticity calcium silicate-based cement. Biodentine and White MTA Angelus were used as reference materials for comparison. Three discs 1 ± 0.1 mm thick were obtained from the middle third of the roots of 5 maxillary canines. Three 0.8-mm-wide holes were drilled on the axial surface of each root disc. Standardized irrigation was performed. Then the holes were dried with paper points and filled with one of the three tested cements. The filled dental slices were immersed in a phosphate-buffered saline (PBS) solution (pH 7.2) for 7 days before the push-out assessment. The Kruskal-Wallis test was applied to assess the effect of each endodontic cement on the push-out bond strength. Mann-Whitney with Bonferroni correction was used to isolate the differences. The alpha-type error was set at 0.05. All specimens had measurable push-out values and no premature failure occurred. There were significant differences among the materials (p <0.05). The Biodentine specimens had the highest push-out bond strength values (p < 0.05). MTA HP had significantly higher bond strength than White MTA (p < 0.05). MTA HP showed better push-out bond strength than its predecessor, White MTA; however, Biodentine had higher dislodgment resistance than both MTA formulations.
Assuntos


Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Óxidos / Colagem Dentária / Silicatos / Compostos de Cálcio / Compostos de Alumínio / Cimentos Dentários Limite: Humanos Idioma: Inglês Revista: Braz. oral res. (Online) Assunto da revista: Odontologia Ano de publicação: 2016 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Estadual de Campinas/BR / Universidade do Grande Rio/BR

Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Óxidos / Colagem Dentária / Silicatos / Compostos de Cálcio / Compostos de Alumínio / Cimentos Dentários Limite: Humanos Idioma: Inglês Revista: Braz. oral res. (Online) Assunto da revista: Odontologia Ano de publicação: 2016 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Universidade Estadual de Campinas/BR / Universidade do Grande Rio/BR
...