Your browser doesn't support javascript.
loading
Análisis de resistencia al desplazamiento de dos cementos de resina, en dentina intrarradicular / Resistance to displacement analysis of two resin cements in intra-root dentin
Miguelena Muro, Karla Eugenia; Guerrero Ibarra, Jorge; Garcilazo Gómez, Alfredo; Ríos Szalay, Enrique.
Afiliação
  • Miguelena Muro, Karla Eugenia; Universidad Nacional Autónoma de México. Facultad de Odontología. MX
  • Guerrero Ibarra, Jorge; Universidad Nacional Autónoma de México. Facultad de Odontología. Departamento de Materiales dentales. MX
  • Garcilazo Gómez, Alfredo; Universidad Nacional Autónoma de México. Facultad de Odontología. MX
  • Ríos Szalay, Enrique; Universidad Nacional Autónoma de México. Facultad de Odontología. MX
Rev. odontol. mex ; 20(4): 238-242, oct.-dic. 2016. tab, graf
Artigo em Espanhol | LILACS | ID: biblio-961575
Biblioteca responsável: MX1.1
RESUMEN
Resumen Para cementar un endoposte reforzado con fibra de vidrio se deben de tomar en cuenta varios factores, entre ellos, la selección del agente cementante. Los cementos disponibles en el mercado difieren por la modalidad de aplicación, tiempo de trabajo, polimerización y composición química, por ello es necesario contar con el conocimiento de todas sus características y su comportamiento no sólo clínico sino también en el laboratorio. Hoy en día la evolución de los cementos de resina va encaminada a la simplificación de la técnica con el fin de reducir tiempo y margen de error durante el proceso clínico, sin embargo, previos estudios han demostrado que estos cambios han reducido la fuerza de adhesióna la dentina.

Objetivo:

El propósito de este estudio es observar el comportamiento de dos agentes cementantes de resina, evaluando su fuerza de adhesión en dentina intrarradicular, el sistema BisCem® de Bisco Inc., el cual es un cemento autoadhesivo dual y el sistema ParaCore® Automix de Colténe/Whaledent; cemento dual que requiere de un agente autoacondicionador y un adhesivo dentinarios de curado químico (ParaBond® de Colténe Whaledent). Material y

métodos:

Se encapsularon 36 dientes unirradiculares en acrílico y se desgastaron hasta descubrir la dentina intrarradicular, siguiendo las especificaciones del fabricante, se realizaron 18 muestras para cada cemento y después se sometieron a pruebas de cizalla a una velocidad de 1 mm por minuto en una máquina de ensayo universal.

Resultados:

Se observó que BisCem® presenta una menor fuerza de adhesión que Para- Core® Automix. Después de analizar estadísticamente los resultados a través de la prueba «T¼ de Student, los resultados mostrando una diferencia significativa entre ambos cementos.

Conclusión:

ParaCore® Automix que requiere previo acondicionado de dentina (ParaBond®) presentan una mayor fuerza de adhesión.
ABSTRACT
Abstract Several factors must be taken into account when cementing an endodontic post reinforced with fiberglass, among them we can mention selection of the cementing agent. Market available cements differ with respect to application mode, working time, polymerization and chemical composition. It is therefore necessary to count with sufficient knowledge of all their characteristics and behavior, not only from the clinical approach, but also in the laboratory. The evolution of resin cements is nowadays geared to technique simplificatión so as to decrease time and margin of error during clinical process. Moreover, previous studies have demonstrated that these changes have decreased adhesion force to dentin.

Objective:

The purpose of the present study was to observe the behavior of two resin cementing agents, assessing their adhesion strength in intra-root dentin the BisCem®, Bisco Inc. system, formed by a dual selfadhesive cement, and the ParaCore® Automix (Coltene/Whaledent) system which is a dual cement system requiring a chemical curing self-conditioning agent and dentin adhesives (ParaBond® Coltene Whaledent). Material and

methods:

Thirty six single rooted teeth we encapsulated in acrylic and worn down until reaching intra-root dentin. Following manufacturer´s instructions, 18 samples were executed for each cement, and then in a universal testing device they were subjected to shearing tests (guillotine test) at a speed of 1 mm per minute.

Results:

It was observed that BisCem® exhibited lesser adhesion force than ParaCore® Automix. After statistically analyzing outcome by means of a «T¼ Student test, results revealed significant difference between both cements.

Conclusion:

ParaCore® Automix, requiring previous dentin conditioning (ParaBond®), exhibited greater adhesion force.


Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Idioma: Espanhol Revista: Rev. odontol. mex Assunto da revista: Odontologia Ano de publicação: 2016 Tipo de documento: Artigo País de afiliação: México Instituição/País de afiliação: Universidad Nacional Autónoma de México/MX

Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Idioma: Espanhol Revista: Rev. odontol. mex Assunto da revista: Odontologia Ano de publicação: 2016 Tipo de documento: Artigo País de afiliação: México Instituição/País de afiliação: Universidad Nacional Autónoma de México/MX
...