Shear bond strength of three different bonding systems for orthodontic brackets
Braz. j. oral sci
; 17: e18138, 2018. tab
Article
em En
| LILACS, BBO
| ID: biblio-963962
Biblioteca responsável:
BR218.1
ABSTRACT
Aim:
The objective of this study was to compare the efficiencies of different adhesive systems used to bond orthodontic brackets as well as the fracture pattern during debonding on bovine teeth.Methods:
The sample included 45 specimens assigned to 3 groups according to the adhesive system applied Group I Transbond XT (3M Unitek®, Monrovia/CA -USA), Group II Orthocem (FGM® Joinville/SC-BR), and Group III Orthobond (Morelli®, Sorocaba/SP-BR). For this purpose, metal brackets were bonded to bovine teeth following the instructions from each manufacturer. The specimens were subjected to a shear test to assess bond strength (BS). Finally, after debonding, the adhesive remnant index (ARI) was estimated.Results:
The average shear strength for a tooth bonded using the adhesive system Transbond XT was 16.39 MPa, while it was 18.08 Mpa for Orthocem and 7.28 Mpa for Orthobond; The Tukey test revealed no statistically significant differences between groups I and II (p < 0.01) and group III differed statistically from groups I and II.Conclusion:
In conclusion, both adhesive systems Transbond XT and Orthocem attained higher bond strength values than Orthobond; the fracture pattern was similar for all adhesive systems appliedPalavras-chave
Texto completo:
1
Coleções:
01-internacional
Base de dados:
BBO
/
LILACS
Assunto principal:
Colagem Dentária
/
Braquetes Ortodônticos
/
Esmalte Dentário
/
Resistência ao Cisalhamento
Limite:
Animals
Idioma:
En
Revista:
Braz. j. oral sci
Assunto da revista:
ODONTOLOGIA
Ano de publicação:
2018
Tipo de documento:
Article
País de afiliação:
Brasil
País de publicação:
Brasil