Comparative study of fibrosis induced by Marlex®, Parietex Composite®, Vicryl® and Ultrapro® meshes1
Acta cir. bras
; 33(9): 792-798, Sept. 2018. graf
Article
em En
| LILACS
| ID: biblio-973505
Biblioteca responsável:
BR1.1
ABSTRACT
Abstract Purpose:
To evaluate the fibrosis induced by four different meshes Marlex®, Parietex Composite®, Vicryl® and Ultrapro®.Methods:
Histological cutouts of abdominal wall were analyzed with polarized light 28 days after the meshes implants and colorized by picrosirius to identify the intensity of collagen types I and III, and their maturation index.Results:
When the four groups were compared, the total collagen area analyzed was bigger in groups A and D, with no difference between them. The collagen type I density was bigger in group A, with an average of 9.62 ± 1.0, and smaller in group C, with an average of 3.86 ± 0.59. The collagen type III density was similar in groups A, B and C, and bigger in group D. The collagen maturation index was different in each of the four groups, bigger in group A with 0.87, group B with 0.66, group D with 0.57 and group C with 0.33 (p = 0.0000).Conclusion:
The most prominent fibrosis promotion in the given meshes was found on Marlex® (polypropylene mesh) and the Parietex Composite® (non-biodegradable polyester); the collagen maturation index was higher in the Marlex® mesh, followed by Ultrapro®, Parietex Composite® and Vicryl® meshes.Palavras-chave
Texto completo:
1
Coleções:
01-internacional
Base de dados:
LILACS
Assunto principal:
Poliésteres
/
Poliglactina 910
/
Polipropilenos
/
Telas Cirúrgicas
/
Colágeno
/
Parede Abdominal
Tipo de estudo:
Etiology_studies
/
Prognostic_studies
Limite:
Animals
Idioma:
En
Revista:
Acta cir. bras
Assunto da revista:
CIRURGIA GERAL
/
Procedimentos Cir£rgicos Operat¢rios
Ano de publicação:
2018
Tipo de documento:
Article
País de afiliação:
Brasil
País de publicação:
Brasil