Your browser doesn't support javascript.
loading
Ângulos visuais: Artigo sobre a importância para o Implante de Lentes Intraoculares Multifocais / Visual angles: Article on the importance of Multifocal Intraocular Lenses Implantation
Lucena, Abrahão Rocha; Braga, Davyson Sampaio; Lucena, Daniel Rocha; Ferreira, Sabine Lucena Martins; Augusto, Ana Lindaura Callou.
Afiliação
  • Lucena, Abrahão Rocha; Escola Cearense de Oftalmologia. Setor Catarata e Refrativa a LASER. Fortaleza. BR
  • Braga, Davyson Sampaio; Escola Cearense de Oftalmologia. Setor de Catarata e Retina. Fortaleza. BR
  • Lucena, Daniel Rocha; Escola Cearense de Oftalmologia. Setor de Retina, Vítreo e Uveítes. Fortaleza. BR
  • Ferreira, Sabine Lucena Martins; Centro Avançado de Retina e Catarata. Setor de Catarata. Fortaleza. BR
  • Augusto, Ana Lindaura Callou; Escola Cearense de Oftalmologia. Programa de Residência em Oftalmologia. Fortaleza. BR
Rev. bras. oftalmol ; 77(5): 268-271, set.-out. 2018. graf
Artigo em Português | LILACS | ID: biblio-977865
Biblioteca responsável: BR1.2
RESUMO
Resumo

Objetivos:

Medir o ângulo lâmbda (AL) em indivíduos no pré-operatório de facectomias, correlacionando a sua presença com o comprimento axial e o esférico dos olhos. Sugerir condutas para o implante de LIO multifocal de acordo com a presença do ângulo lâmbda.

Métodos:

Estudo transversal em 128 olhos de 74 indivíduos candidatos à cirurgia de catarata para registrar a equivalente presença do ângulo lâmbda.

Resultados:

Avaliando o ângulo lâmbda observou-se uma correlação positiva (r= 0,559 / p= 0,000) para o tamanho desse ângulo comparando-se os dois olhos. Não houve correlação entre o tamanho do ângulo lâmbda e o equivalente esférico no olho direito (r= -0,027 / p= 0,840), mas foi verificada correlação positiva para o olho esquerdo (r= 0,313 / p= 0,013). A presença da hipermetropia correlacionou com os comprimentos axiais pequenos, assim como a miopia com os grandes. Observou-se correlação negativa entre o tamanho do ângulo lâmbda e o comprimento axial para os dois olhos, sendo de r= -0,249 para o olho direito (p= 0,042) e r= -0,281 para o olho esquerdo (p= 0,018)

Conclusões:

Houve correlação entre a presença de ângulo lâmbda maior e comprimentos axiais menores para os dois olhos. Para o equivalente esférico hipermétrope houve correlação com a presença de um ângulo lâmbda maior apenas para o olho esquerdo. Esse trabalho sugere parcimônia nos implantes de LIO multifocal na presença de ângulo lâmbda significativo, baseado na teoria que a presença desse ângulo é reguladora do equilíbrio entre as aberrações da superfície corneana versus cristalineanas.
ABSTRACT
Abstract

Objectives:

To measure the labral angle (LA) in individuals in the preoperative period of facectomies, correlating their presence with axial length and spherical equivalent of the eyes. Suggest conduits for the implantation of multifocal IOL according to the presence of the lambda angle.

Methods:

A cross-sectional study of 128 eyes of 74 individuals who were candidates for cataract surgery to record the presence of the lambda angle.

Results:

A positive correlation (r = 0.559 / p = 0.000) was observed for the angle of this angle by comparing the two eyes. There was no correlation between the size of the lambda angle and the spherical equivalent in the right eye (r = -0.027 / p = 0.840), but a positive correlation was observed for the left eye (r = 0.313 / p = 0.013). The presence of hyperopia correlated with small axial lengths, as did myopia with large ones. There was a negative correlation between the angle of the tongue and the axial length of the two eyes, with r = -0.249 for the right eye (p = 0.042) and = 0.281 for the left eye (p = 0.018).

Conclusions:

There was a correlation between the presence of a larger lambda angle and smaller axial lengths for both eyes. For the spherical hypermétrope equivalent, there was a correlation with the presence of a larger blunt angle only for the left eye. This work suggests parsimony in multifocal IOL implants in the presence of a significant lamella angle, based on the theory that the presence of this angle regulates the balance between corneal versus crystaline surface aberrations.
Assuntos


Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Pupila / Topografia da Córnea / Implante de Lente Intraocular / Comprimento Axial do Olho / Lentes Intraoculares Multifocais Tipo de estudo: Estudo observacional / Estudo de prevalência / Fatores de risco Limite: Adulto / Idoso / Idoso, 80 anos ou mais / Feminino / Humanos / Masculino Idioma: Português Revista: Rev. bras. oftalmol Assunto da revista: Oftalmologia Ano de publicação: 2018 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Centro Avançado de Retina e Catarata/BR / Escola Cearense de Oftalmologia/BR

Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Pupila / Topografia da Córnea / Implante de Lente Intraocular / Comprimento Axial do Olho / Lentes Intraoculares Multifocais Tipo de estudo: Estudo observacional / Estudo de prevalência / Fatores de risco Limite: Adulto / Idoso / Idoso, 80 anos ou mais / Feminino / Humanos / Masculino Idioma: Português Revista: Rev. bras. oftalmol Assunto da revista: Oftalmologia Ano de publicação: 2018 Tipo de documento: Artigo País de afiliação: Brasil Instituição/País de afiliação: Centro Avançado de Retina e Catarata/BR / Escola Cearense de Oftalmologia/BR
...