Your browser doesn't support javascript.
loading
Avaliação da Ocorrência da Fenda Marginal em Restaurações de Resina Composta / Occurrence Evaluation of the Marginal Gap in Composite Resin Restorations
São José dos Campos; s.n; 2018. 58 p. il., tab., graf..
Thesis em Pt | BBO | ID: biblio-980635
Biblioteca responsável: BR243.1
Localização: BR243.1; 1116. 2301
RESUMO
O objetivo do estudo foi avaliar a ocorrência da fenda marginal em restaurações de resinas flow, com e sem ciclagem termomecânica. Utilizou-se neste estudo 60 incisivos bovinos. Os preparos cavitários foram padronizados por meio de um dispositivo que proporcionou preparos uniformizados realizados com uma ponta diamantada (3286P-KG Sorensen). O sistema adesivo Single Bond Universal (3MESPE) foi aplicado e os compósitos foram utilizados FILTEK BULK FILL FLOW (3MESPE), ADMIRA FUSION FLOW (VOCO) e FILTEK Z350 XT FLOW (3M ESPE). Metade dos espécimes foram submetidos à ciclagem termomecânica. Foi realizada a avaliação da área da fenda marginal por meio da medição no microscópio óptico DISCOVERY V20 (ZEISS). Os valores de média e desvio-padrão de área da fenda marginal (µm²) obtidos nos 6 grupos estudados foram FBNC = 332,75 ± 214,76; AFNC = 376,20 ± 196,04; FZNC = 861,12 ± 393,68; FBC = 951,68 ± 273,67; AFC = 598,82 ± 392,60; FZC = 1157,59 ± 563,76. O teste ANOVA dois fatores apresentou o valor de p< 0,05 para ambos os fatores, o teste de Tukey a 5% mostrou média e desvio padrão (µm²) para o fator envelhecimento com ciclagem = 902,70 ± 455,37ª; sem ciclagem = 523,35 ± 345,28ᵇ, e para o fator resina composta mostrou média e desvio padrão (µm²) FZ = 1009,36 ± 466,43ª; FB = 642,21 ± 399,27ªáµ‡; AF = 487,51 ± 307,80ᵇ. A ciclagem termomecânica resultou no aumento da área da fenda marginal, a resina AF apresentou resultados superiores em relação á FZ. A resina FB não apresentou diferenças em relação as demais(AU)
ABSTRACT
The aim of this study was to evaluate the occurrence of marginal gap of different restorations, using different flowable composite, with and without thermo mechanical cycling. 60 incisive bovine tooth were used. The cavity preparations were standardized by means of a device that provided uniform preparations made with a diamond bur (3286P, KG Sorensen, Barueri, SP, Brazil). Universal Single Bond (3M) adhesive system was applied and the composites were applied FILTEK BULK FILL FLOW (3M), ADMIRA FUSION FLOW (VOCO) e FILTEK Z350 XT FLOW (3M). Half of each group were submitted to thermo cycling. Evaluation of marginal gap were done by optical microscopy DISCOVERY V20 (ZEISS). The mean and standard deviation values of the marginal gap area (µm²) obtained in the 6 groups studied were FBNC = 332,75 ± 214,76; AFNC = 376,20 ± 196,04; FZNC = 861,12 ± 393,68; FBC = 951,68 ± 273,67; AFC = 598,82 ± 392,60; FZC = 1157,59 ± 563,76. The twoway ANOVA presented p lesser than 0.05 for both factors, the Tukey test at 5% showed mean and standard deviation (µm²) for termo mechanical cycling factor Cycling = 902,70 ± 455,37ª; No cycling = 523,35 ± 345,28ᵇ and for composite resin factor FZ = 1009,36 ± 466,43ª; FB = 642,21 ± 399,27ªáµ‡; AF = 487,51 ± 307,80ᵇ. The thermomechanical cycling resulted in an increase in the marginal gap area; and the composite AF presented statistically superior results in relation to FZ. The FB composite showed no differences in relation to the other composites(AU)
Assuntos
Palavras-chave
Texto completo: 1 Coleções: 06-national Base de dados: BBO Assunto principal: Resinas Compostas Tipo de estudo: Screening_studies Limite: Humans Idioma: Pt Ano de publicação: 2018 Tipo de documento: Thesis
Texto completo: 1 Coleções: 06-national Base de dados: BBO Assunto principal: Resinas Compostas Tipo de estudo: Screening_studies Limite: Humans Idioma: Pt Ano de publicação: 2018 Tipo de documento: Thesis