Your browser doesn't support javascript.
loading
Evaluación del agua corporal medida por bioimpedancia eléctrica en adultos jóvenes sanos y su correlación estimada según formulaciones convencionales / Evaluation of body water measured by electric bio impedance in young healthy adults and its estimated correlation using conventional formula
Gallardo Castro, Joseph Arturo; Zapata Negreiros, José Aarón; Lluncor Vásquez, Juan Oscar; Cieza Zevallos, Javier Antonio.
Afiliação
  • Gallardo Castro, Joseph Arturo; Universidad Peruana Cayetano Heredia. Facultad de Medicina Alberto Hurtado. Lima. PE
  • Zapata Negreiros, José Aarón; Universidad Peruana Cayetano Heredia. Facultad de Medicina Alberto Hurtado. Lima. PE
  • Lluncor Vásquez, Juan Oscar; Universidad Peruana Cayetano Heredia. Facultad de Medicina Alberto Hurtado. Lima. PE
  • Cieza Zevallos, Javier Antonio; Universidad Peruana Cayetano Heredia. Facultad de Medicina Alberto Hurtado. Lima. PE
Rev. méd. hered ; 27(3): 146-151, jul.-sept. 2016. tab, graf
Artigo em Espanhol | LILACS, LIPECS | ID: biblio-982875
Biblioteca responsável: PE1.1
RESUMEN

Objetivos:

Comparar la precisión de las fórmulas antropométricas de Watson, Hume-Weyers, y el basado en elporcentaje del peso según sexo, para estimar el agua corporal total en relación a la medida por bioimpedanciaeléctrica considerando ésta como gold standard. Material y

métodos:

Se enrolaron 17 voluntarios sanos entre 21a 29 años de edad, con antropometría normal y en condiciones de vida cotidiana. Para evaluar la precisión en laestimación del agua corporal se usó la t de Student pareada y para estimar el error sistemático se usó el análisisde regresión lineal y la correlación de Pearson...
ABSTRACT

Objectives:

To compare the precision of Watson´s, Hume-Weyers´ anthropometric formula and that based on thebody percentage by gender to estimate de total body water in relation to that measured by electric bio impedanceconsidering the latter as the gold standard.

Methods:

17 healthy volunteers with normal anthropometric valuesbetween 21 and 29 years were recruited. Paired students´ t-test was used to evaluate the precision in the estimationof body water, and logistic regression analysis and Pearson´s correlation was used to evaluate systematic error...
Assuntos


Texto completo: Disponível Coleções: Bases de dados nacionais / Peru Base de dados: LILACS / LIPECS Assunto principal: Água Corporal / Antropometria / Impedância Elétrica Tipo de estudo: Estudo observacional / Estudo de prevalência / Fatores de risco Limite: Humanos Idioma: Espanhol Revista: Rev. méd. hered Ano de publicação: 2016 Tipo de documento: Artigo Instituição/País de afiliação: Universidad Peruana Cayetano Heredia/PE

Texto completo: Disponível Coleções: Bases de dados nacionais / Peru Base de dados: LILACS / LIPECS Assunto principal: Água Corporal / Antropometria / Impedância Elétrica Tipo de estudo: Estudo observacional / Estudo de prevalência / Fatores de risco Limite: Humanos Idioma: Espanhol Revista: Rev. méd. hered Ano de publicação: 2016 Tipo de documento: Artigo Instituição/País de afiliação: Universidad Peruana Cayetano Heredia/PE
...