Your browser doesn't support javascript.
loading
Aplicación de un método analítico revalidado por cromatografía líquida para la cuantificación de permetrina 1 por ciento / High performance liquid chromatography-validated analytical method for 1 percent permethrin quantification
Tarinas Reyes, Alicia; Tßpanes Peraza, Rolando D; Fernández Rangel, Ditter; Hernández Contreras, Natividad.
Afiliação
  • Tarinas Reyes, Alicia; Instituto de Medicina Tropical Pedro Kourí. La Habana. Cuba
  • Tßpanes Peraza, Rolando D; Instituto de Medicina Tropical Pedro Kourí. La Habana. Cuba
  • Fernández Rangel, Ditter; Grupo de Ingeniería Ambiental UCTB y Corrosión. Centro de Investigaciones del Petróleo. s.p
  • Hernández Contreras, Natividad; Instituto de Medicina Tropical Pedro Kourí. La Habana. Cuba
Rev. cuba. med. trop ; 63(1)ene.-abr. 2011. graf
Artigo em Espanhol | CUMED | ID: cum-50316
Biblioteca responsável: CU1.1
RESUMEN

INTRODUCCIÓN:

en Cuba, al igual que en otros países, la infestación por Pediculus capitis se ha incrementado notablemente a partir de la década de los setenta, por lo que se desarrolla un intenso programa dirigido a su control y prevención, en el cual se incluyen estudios sobre la calidad de la permetrina, que es un piretroide sintético, activo frente a una amplia gama de parásitos, con actividad pediculicida a 1 por ciento y escabicida a 5 por ciento. Dada su baja toxicidad y por responder favorablemente a la relación riesgo/beneficio, constituye uno de los pediculicidas de elección para disminuir la infestación por piojos.

OBJETIVO:

revalidación de una metódica analítica por cromatografía líquida de alta resolución y su aplicación en la cuantificación de 12 muestras de 2 lotes de loción de permetrina 1 por ciento, de producción nacional.

MÉTODOS:

los parámetros evaluados fueron linealidad, precisión y exactitud. Se prepararon 7 estándares de calibración y soluciones de trabajo con concentraciones que se encontraban entre 100 y 15 000 Ág/mL. Estos parámetros de validación fueron verificados a través del coeficiente de correlación, el coeficiente de variación y el error relativo porcentual.

RESULTADOS:

la especificidad del método fue corroborada a través de los cromatogramas realizados, en los cuales los tiempos de retención fueron entre 8,8 y 9,2 min para el isómero trans y entre 10,7 y 11,2 min para el isómero cis. El coeficiente de correlación determinado para ambos isómeros fue mayor que 0,99; el coeficiente de variación fue menor que 3 por ciento y el error relativo porcentual estuvo entre -3 y 1 por ciento, tanto para los estudios interdía como intradía. Se determinó que la media de la concentración de permetrina en lotes de solución tópica 1 por ciento resultó de 6 780,14 Ág/mL.

CONCLUSIONES:

el método revalidado fue lineal, preciso y exacto dentro del rango de concentraciones estudiadas. La concentración de permetrina calculada estuvo por debajo...(AU)
ABSTRACT

INTRODUCTION:

in Cuba, as well as in other countries, Pediculus capitis infestation has increased since the 70´s; this is the reason why a program aimed at controlling and preventing this infestation was designed. This program includes quality control studies of the active synthetic pyrethroid Permethrin and its activity at 1 percent on lice and 5 percent on scabies. Due to its low toxicity and positive risk/benefit ratio, Permethrin is a pediculicide of choice to decrease Pediculus capitis infestation.

OBJECTIVE:

to validate an analytical method using high performance liquid chromatography and its application in the quantification of 12 samples from 2 batches of Cuban-made 1 percent permethrin pediculicidal preparation.

METHODS:

linearity, precision and accuracy parameters were determined. Seven calibration standards and working solutions with concentrations ranging from 100 to 15 000 Ág/mL were prepared. These validation parameters were verified through the correlation coefficient, the variation coefficient and the percentage relative error.

RESULTS:

the specificity of this method was proved in the chromatograms that showed retention times of 8.8 to 9.2 min for the isomer trans and 10.7 to 11.2 min for the isomer cis. The correlation coefficient for both isomers was higher than 0.99; the variation coefficient was under 3 percent and the percentage relative error was -3 and 1 percent for the inter-day and intraday studies, respectively. The mean permethrin concentration in 1 percent solution batches was estimated at 6 780.14 Ág/mL.

CONCLUSIONS:

the validated method was linear, precise and exact within the range of the studied concentrations. The estimated concentration of permethrin was below the expected rate according to the composition of 1 percent permethrin solution (9 100-10 900 Ág/mL). This method may be useful for the quantification of 1 percent permethrin solutions in the quality studies of the product sold to the population (AU)
Assuntos

Texto completo: Disponível Coleções: Bases de dados nacionais / Cuba Contexto em Saúde: ODS3 - Meta 3.3 Acabar com as doenças tropicais negligenciadas e combater as doenças transmissíveis Problema de saúde: Escabiose Base de dados: CUMED Assunto principal: Cromatografia Líquida de Alta Pressão / Permetrina País/Região como assunto: Caribe / Cuba Idioma: Espanhol Revista: Rev. cuba. med. trop Ano de publicação: 2011 Tipo de documento: Artigo Instituição/País de afiliação: Grupo de Ingeniería Ambiental UCTB y Corrosión/s.p / Instituto de Medicina Tropical Pedro Kourí/Cuba
Texto completo: Disponível Coleções: Bases de dados nacionais / Cuba Contexto em Saúde: ODS3 - Meta 3.3 Acabar com as doenças tropicais negligenciadas e combater as doenças transmissíveis Problema de saúde: Escabiose Base de dados: CUMED Assunto principal: Cromatografia Líquida de Alta Pressão / Permetrina País/Região como assunto: Caribe / Cuba Idioma: Espanhol Revista: Rev. cuba. med. trop Ano de publicação: 2011 Tipo de documento: Artigo Instituição/País de afiliação: Grupo de Ingeniería Ambiental UCTB y Corrosión/s.p / Instituto de Medicina Tropical Pedro Kourí/Cuba
...