Your browser doesn't support javascript.
loading
Caracterización del ambiente físico en viviendas de hormigón en La Coronela, La Habana, 2010-2011 / Characterization of physical environment in concrete houses, La Coronela, Havana, 2010-2011
Barceló Pérez, Carlos; Guzmán Piñeiro, Raisa; Ramírez Sotolongo, Juan C; Calderón Baró, Joán; Sao Ravelo, Leonardo.
Afiliação
  • Barceló Pérez, Carlos; Instituto Nacional de Higiene, Epidemiología y Microbiología. La Habana. Cuba
  • Guzmán Piñeiro, Raisa; Instituto Nacional de Higiene, Epidemiología y Microbiología. La Habana. Cuba
  • Ramírez Sotolongo, Juan C; Instituto Nacional de Higiene, Epidemiología y Microbiología. La Habana. Cuba
  • Calderón Baró, Joán; Instituto Nacional de Higiene, Epidemiología y Microbiología. La Habana. Cuba
  • Sao Ravelo, Leonardo; Instituto Nacional de Higiene, Epidemiología y Microbiología. La Habana. Cuba
Rev. cuba. hig. epidemiol ; 51(2)mayo-ago. 2013. tab
Artigo em Espanhol | CUMED | ID: cum-58151
Biblioteca responsável: CU1.1
Localização: CU1.1
RESUMEN

Introducción:

el creciente aumento de la población ha ocasionado un déficit cuantitativo de viviendas, el cual es abordado desde diferentes soluciones constructivas. Una de ellas es la vivienda de edificios multifamiliares de hormigón, conocida como FORSA.

Objetivos:

caracterizar, desde el punto de vista sanitario, ambientes físicos de viviendas FORSA de edificios multifamiliares en el asentamiento La Coronela, en La Habana.

Métodos:

Para lograr esta caracterización se estudiaron factores de riesgo, como el microclima, temperaturas de cubiertas y envolventes y la penetración del viento, campos de radiación no ionizante de muy baja frecuencia (ELF), clima luminoso y ruido durante una semana correspondiente a la estación húmeda del año 2010 y otra a la estación seca de 2011. Se seleccionaron nueve viviendas de edificios multifamiliares de tres y cinco plantas, ubicadas en niveles bajos y altos, con y sin aleros, y con distintas orientaciones de fachada.

Resultados:

existía calor moderado en las dos estaciones estudiadas, que fue algo más cálido en las viviendas de edificios multifamiliares de cinco plantas. El nivel de la vivienda y la presencia de aleros no parecieron ofrecer efecto importante en el clima interior. El viento exterior penetró poco en los interiores. El componente magnético del campo ELF no transgredió los valores guía de la Organización Mundial de la Salud. La iluminación natural resultó apropiada, no así la artificial, pero los coeficientes de reflexión de pisos resultan elevados. El nivel sonoro incumplió la norma sanitaria vigente NC 26 de 2012 aplicada para nuevas urbanizaciones.

Conclusiones:

El ambiente interior de las viviendas FORSA del asentamiento La Coronela presenta un clima ligeramente inconfortable para los residentes, independientemente del nivel de la vivienda y la presencia de aleros(AU)
ABSTRACT

Background:

The growing increase in population has caused a quantitative deficit of houses which has been approached from different constructive solutions. One of these is the house of multifamily buildings made of concrete, known as FORSA.

Objectives:

to characterize, from a sanitary point of view, physical environments of FORSA houses of multifamily buildings in La Coronela settlement in Havana.

Methods:

to achieve this characterization, different risk factors were studied such as microclimate, cover and enclosure temperatures and wind penetration, non-ionizing radiation fields of extremely low frequency (ELF), light climate and noise during a week corresponding to the wet season of the year 2010 and another corresponding to the dry season of the year 2011. Nine houses of multifamily buildings of three and five floors were selected. They were located in low and high levels, with or without eaves and with different facade orientations.

Results:

there was moderate warmth in the two seasons studied, which was somewhat warmer in the houses of five floor multifamily buildings. The level of the houses and the presence of eaves seemed to offer no significant effect on the indoor climate. The external wind hardly penetrated indoors. The magnetic component of ELF field did not transgress the reference values of the World Health Organization. Natural lighting was appropriate but not the artificial one; whereas the reflection coefficients of floors were higher. The sound level breached the current sanitary standard NC 26 of 2012.

Conclusions:

the environment inside FORSA houses in the settlement "La Coronela" presents a slightly uncomfortable climate for residents, regardless the levels of houses and the presence of eaves(AU)
Assuntos

Texto completo: Disponível Coleções: Bases de dados nacionais / Cuba Contexto em Saúde: ODS3 - Saúde e Bem-Estar Problema de saúde: Meta 3.8 Atingir a cobertura universal de saúde Base de dados: CUMED Assunto principal: Qualidade Ambiental / Perfis Sanitários / Edifícios / Habitação Tipo de estudo: Fatores de risco Aspecto: Determinantes sociais da saúde Idioma: Espanhol Revista: Rev. cuba. hig. epidemiol Ano de publicação: 2013 Tipo de documento: Artigo Instituição/País de afiliação: Instituto Nacional de Higiene, Epidemiología y Microbiología/Cuba
Texto completo: Disponível Coleções: Bases de dados nacionais / Cuba Contexto em Saúde: ODS3 - Saúde e Bem-Estar Problema de saúde: Meta 3.8 Atingir a cobertura universal de saúde Base de dados: CUMED Assunto principal: Qualidade Ambiental / Perfis Sanitários / Edifícios / Habitação Tipo de estudo: Fatores de risco Aspecto: Determinantes sociais da saúde Idioma: Espanhol Revista: Rev. cuba. hig. epidemiol Ano de publicação: 2013 Tipo de documento: Artigo Instituição/País de afiliação: Instituto Nacional de Higiene, Epidemiología y Microbiología/Cuba
...