Your browser doesn't support javascript.
loading
Manipulador uterino "KD" como nuevo dispositivo para la histerectomía totalmente laparoscópica / Uterine manipulator KD as a new device for the fully laparoscopic hysterectomy
García Baños, Luis Gustavo; Barreras González, Javier Ernesto; Días Ortega, Israel; Castillo Sánchez, Yudelkys; Pereira Fraga, Jorge Gerardo; López Milhet, Ana Bertha.
Afiliação
  • García Baños, Luis Gustavo; Centro Nacional de Cirugía de Mínimo Acceso. La Habana. CUBA
  • Barreras González, Javier Ernesto; Centro Nacional de Cirugía de Mínimo Acceso. La Habana. CUBA
  • Días Ortega, Israel; Centro Nacional de Cirugía de Mínimo Acceso. La Habana. CUBA
  • Castillo Sánchez, Yudelkys; Centro Nacional de Cirugía de Mínimo Acceso. La Habana. CUBA
  • Pereira Fraga, Jorge Gerardo; Centro Nacional de Cirugía de Mínimo Acceso. La Habana. CUBA
  • López Milhet, Ana Bertha; Centro Nacional de Cirugía de Mínimo Acceso. La Habana. CUBA
Rev. cuba. cir ; 57(2): 1-9, abr.-jun. 2018. ilus, tab
Artigo em Espanhol | CUMED | ID: cum-72067
Biblioteca responsável: CU1.1
Localização: CU1.1
RESUMEN

Introducción:

Uno de los factores que han influido para lograr una mayor aceptación de la histerectomía totalmente laparoscópica es la introducción de dispositivos que permiten mejorar la movilización del útero durante la cirugía.

Objetivo:

Evaluar el manipulador uterino KD de producción nacional en la histerectomía totalmente laparoscópica.

Método:

Estudio prospectivo longitudinal en una serie inicial en humanos. El univero estuvo conformado por las pacientes con patologías uterinas tributarias de tratamiento quirúrgico. La muestra la constituyeron 50 pacientes que cumplieron los criterios de inclusión. Las variables en estudio fueron realización de la histerectomía, efectos adversos del sistema rígido en el manipulador diseñado, del sistema neumo oclusor, indicación de la operación, peso del útero, sangramiento intraoperatorio, índice de masa corporal, tiempo quirúrgico, morbilidad intraoperatoria y posoperatoria. El análisis estadístico fue realizado por una especialista en Bioestadísticas, mediante el programa estadístico IBM-SPSS versión 21 para Windows en español. Como medidas de resumen, las frecuencias absolutas, frecuencias relativas tales como el porcentaje, la media y el rango, así como la asociación de Spearman.

Resultados:

Solo existió un efecto adverso con el manipulador uterino la perforación de un útero de 55 g. El mioma uterino fue la principal indicación de la histerectomía, el tiempo quirúrgico; así como el sangrado intraoperatorio, estuvieron acordes con otros resultados. Existió una correlación entre peso del útero, sangrado y tiempo quirúrgico.

Conclusiones:

La histerectomía totalmente laparoscópica con el uso del manipulador uterino diseñado se realizó en la totalidad de las pacientes con resultados aceptables(AU)
ABSTRACT

Introduction:

One of the factors that have influenced for achieving greater acceptance of the fully laparoscopic hysterectomy is the introduction of devices that allow to improve the mobilization of the uterus during surgery.

Objective:

To assess the uterine manipulator KD of domestic production, in the totally laparoscopic hysterectomy.

Method:

Longitudinal prospective study in an initial series in humans. The total sample was made up by patients with uterine pathologies and who were candidates for surgical treatment. The sample consisted of 50 patients who met the inclusion criteria. The variables under study were hysterectomy, adverse effects of the rigid system on the designed manipulator, pneumo-occlusion system, indication of the operation, uterine weight, intraoperative bleeding, body mass index, surgical time, intraoperative and postoperative morbidity. The statistical analysis was carried out by a specialist in Biostatistics, using the statistical program IBM-SPSS version 21 for Windows in Spanish. As summary measures, we used absolute frequencies, relative frequencies such as the percentage, the mean and the range, as well as the Spearman association.

Results:

There was only an adverse effect with the uterine manipulator, which was the perforation of a 55-gr uterus. The uterine myoma was the main indication for hysterectomy; the surgical time, as well as intraoperative bleeding, were consistent with other results. There was a correlation between uterine weight, bleeding and surgical time.

Conclusions:

The fully laparoscopic hysterectomy with the use of the designed uterine manipulator was performed in all of the patients and with acceptable results(AU)
Assuntos

Texto completo: Disponível Coleções: Bases de dados nacionais / Cuba Base de dados: CUMED Assunto principal: Laparoscopia / Equipamentos e Provisões / Histerectomia Vaginal Tipo de estudo: Estudo observacional / Fatores de risco Limite: Feminino / Humanos Idioma: Espanhol Revista: Rev. cuba. cir Ano de publicação: 2018 Tipo de documento: Artigo Instituição/País de afiliação: Centro Nacional de Cirugía de Mínimo Acceso/CUBA
Texto completo: Disponível Coleções: Bases de dados nacionais / Cuba Base de dados: CUMED Assunto principal: Laparoscopia / Equipamentos e Provisões / Histerectomia Vaginal Tipo de estudo: Estudo observacional / Fatores de risco Limite: Feminino / Humanos Idioma: Espanhol Revista: Rev. cuba. cir Ano de publicação: 2018 Tipo de documento: Artigo Instituição/País de afiliação: Centro Nacional de Cirugía de Mínimo Acceso/CUBA
...