A lesson learned from Loma Prieta on Vulnerability of URM construction east of the rockies
In. U.S. Central United States Earthquake Consortium (CUSEC). Mitigation and damage to the built environment. Memphis, Tennessee, U.S. Central United States Earthquake Consortium (CUSEC), 1993. p.143-52, ilus.
Monografia
em En
| Desastres
| ID: des-6663
Biblioteca responsável:
CR3.1
Localização: CR3.1; DES
ABSTRACT
A two - story unreinforced masonry structure located within 15 Km of the epicenter of Loma Prieta responded with litte damage despite roof accelerations as large as 0.79g. The historical building has constructed of clay brick masonry bearing walls, and timber floor and roof systems. Measure of response of the building during the earthquake is used with measured material data to infer how similar construction east of the Rockies might perform during a future seismic event (AU)