Your browser doesn't support javascript.
loading
Disociación del polietileno de una copa acetabular no cementada. Aportación de 11 casos / Polyethylene liner disassociation in a non-cemented acetabular Cup: 11 cases
López-Sastre-Núñez, A; Mencía-Barrio, R; Alonso-Barrio, J. A; González-Fernández, J. J.
Afiliação
  • López-Sastre-Núñez, A; Hospital de León. León. España
  • Mencía-Barrio, R; Hospital de León. León. España
  • Alonso-Barrio, J. A; Hospital de León. León. España
  • González-Fernández, J. J; Hospital de León. León. España
Rev. ortop. traumatol. (Madr., Ed. impr.) ; 50(6): 431-436, nov. 2006.
Artigo em Es | IBECS | ID: ibc-051310
Biblioteca responsável: ES1.1
Localização: ES1.1 - BNCS
RESUMEN
Objetivo. Se estudian los casos de disociación del núcleo de polietileno de la copa metálica no cementada Cerafit® (Ceraver-Osteal, Roisy, Francia). Material y método. Once casos de disociación polietileno-copa metálica, de los cuales en cinco se reconoció un antecedente traumático y en los otros seis una clínica insidiosa. Resultados. Cuando la clínica se presentó de forma aguda se apreció una luxación del núcleo del polietileno con rotura del mecanismo de anclaje. Mientras que los pacientes con clínica insidiosa presentaron diferentes grados de usura del polietileno y abrasión de la copa metálica con metalosis. En todos los casos se recambiaron el cótilo y el vástago femoral. Conclusión. La disociación del núcleo de polietileno de la copa metálica es una complicación de la artroplastia total de cadera relativamente rara. Si no se reconoce a tiempo, las consecuencias pueden ser catastróficas
ABSTRACT
Materials and methods. Eleven cases were seen of disassociation of the polyethylene liner from the metallic acetabular shell. In five cases there was trauma and the other six had an insidious clinical evolution. Results. In the cases with acute onset there was dislocation of the polyethylene liner and rupture of the fixation mechanism. In the cases with an insidious clinical evolution, there were different degrees of wear of the polyethylene with abrasion of the metallic acetabular shell and metallosis. All cases underwent revision with replacement of the acetabular cup and the femoral stem. Conclusion. Disassociation of the polyethylene liner from the metallic acetabular shell is a relatively rare complication in total hip replacement. But if it is not recognized in time the consequences can be catastrophic
Assuntos
Buscar no Google
Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Falha de Prótese / Osteoartrite do Quadril / Artroplastia de Quadril / Prótese de Quadril Limite: Idoso / Feminino / Humanos / Masculino Idioma: Espanhol Revista: Rev. ortop. traumatol. (Madr., Ed. impr.) Ano de publicação: 2006 Tipo de documento: Artigo Instituição/País de afiliação: Hospital de León/España
Buscar no Google
Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Falha de Prótese / Osteoartrite do Quadril / Artroplastia de Quadril / Prótese de Quadril Limite: Idoso / Feminino / Humanos / Masculino Idioma: Espanhol Revista: Rev. ortop. traumatol. (Madr., Ed. impr.) Ano de publicação: 2006 Tipo de documento: Artigo Instituição/País de afiliação: Hospital de León/España
...