Your browser doesn't support javascript.
loading
Valor diagnóstico de la ecografía Doppler color en el control clínico de la reparación endovascular de los aneurismas de aorta abdominal / The diagnostic value of colour Doppler ultrasonography in the clinical monitoring of endovascular abdominal aortic aneurysm repair
San Norberto García, Enrique M; Blanco Alonso, M. Isabel del; Ibáñez Maraña, María A; Cenizo Revuelta, Noelia; Brizuela Sanz, José Antonio; Mengíbar Fuentes, Lucas; Gutiérrez Alonso, Vicente M; González Fajardo, José Antonio; Río Solá, M. Lourdes del; Carrera Díaz, Santiago A; Vaquero Puerta, Carlos.
Afiliação
  • San Norberto García, Enrique M; Hospital Cínico Universitario de Valladolid. Valladolid. España
  • Blanco Alonso, M. Isabel del; Hospital Cínico Universitario de Valladolid. Valladolid. España
  • Ibáñez Maraña, María A; Hospital Cínico Universitario de Valladolid. Valladolid. España
  • Cenizo Revuelta, Noelia; Hospital Cínico Universitario de Valladolid. Valladolid. España
  • Brizuela Sanz, José Antonio; Hospital Cínico Universitario de Valladolid. Valladolid. España
  • Mengíbar Fuentes, Lucas; Hospital Cínico Universitario de Valladolid. Valladolid. España
  • Gutiérrez Alonso, Vicente M; Hospital Cínico Universitario de Valladolid. Valladolid. España
  • González Fajardo, José Antonio; Hospital Cínico Universitario de Valladolid. Valladolid. España
  • Río Solá, M. Lourdes del; Hospital Cínico Universitario de Valladolid. Valladolid. España
  • Carrera Díaz, Santiago A; Hospital Cínico Universitario de Valladolid. Valladolid. España
  • Vaquero Puerta, Carlos; Hospital Cínico Universitario de Valladolid. Valladolid. España
Angiología ; 59(1): 29-37, ene.-feb. 2007. ilus, tab
Artigo em Es | IBECS | ID: ibc-051920
Biblioteca responsável: ES1.1
Localização: ES1.1 - BNCS
RESUMEN
Introducción. El control clínico del tratamiento endovascular de la enfermedad aneurismática de la aorta abdominal se basa en la valoración de la evolución del tamaño del aneurisma, la permeabilidad de la endoprótesis y la detección de fugas. Objetivo. Comparar la ecografía Doppler (ED) color con la tomografía axial computarizada (TAC) en la evaluación del tamaño del aneurisma y la detección de fugas en el tratamiento endovascular de aneurismas de aorta abdominal. Pacientes y métodos. Estudio prospectivo entre enero y diciembre de 2005. En 14 pacientes sometidos a tratamiento endovascular se realizó ED color y TAC a 1, 6 y 12 meses. Se compararon los tamaños del aneurisma mediante la prueba t para muestras dependientes y estudio de correlación. Sensibilidad, especificidad, valor predictivo positivo y valor predictivo negativo y el coeficiente de concordancia kappa se calcularon para la detección de fugas. Resultados. El control clínico medio fue de 9,4 meses y se compararon 49 exploraciones. El diámetro medio del aneurisma a los tres meses de control clínico fue de 51,2 cm con ED color y de 52,5 cm con TAC (p = no significativo). El coeficiente de correlación ascendió a 0,97 (p < 0,001). Todos los dispositivos se mantuvieron permeables. En detección de fugas, el estudio ED color obtuvo una sensibilidad, especificidad, valor predictivo positivo y valor predictivo negativo de 75, 61, 20 y 95%, respectivamente (kappa = 0,61). Conclusiones. El estudio ED color obtiene una excelente correlación con la TAC en la medida del tamaño de los aneurismas. En cambio, posee un valor predictivo positivo muy bajo para la detección de fugas
ABSTRACT
Introduction. Clinical monitoring of the endovascular treatment of aneurysmal disease of the abdominal aorta is based on evaluating the progression of the size of the aneurysm, the patency of the stent and the detection of leaks. Aim. To compare colour Doppler ultrasonography (DU) with computerised axial tomography (CAT) for evaluating the size of the aneurysm and the detection of leaks in the endovascular treatment of abdominal aortic aneurysms. Patients and methods. A prospective study between January and December 2005; colour DU and CAT scans were conducted in 14 patients submitted to endovascular treatment at 1, 6 and 12 months. Sizes of the aneurysms were compared by means of the t test for dependent samples and correlation studies. Sensitivity, specificity, predictive positive value and predictive negative value and the kappa coefficient of agreement were calculated for leak detection. Results. The mean period of clinical monitoring was 9.4 months and 49 examinations were compared. The mean diameter of the aneurysm at three months’ clinical monitoring was 51.2 cm with colour DU and 52.5 cm with CAT scanning (p = non-significant). The correlation coefficient was 0.97 (p < 0.001). Patency was maintained in all the devices. In the detection of leaks, the results of the colour DU study for sensitivity, specificity, predictive positive value and predictive negative value were 75, 61, 20 and 95%, respectively (kappa = 0.61). Conclusions. The colour DU study correlates very well with CAT in the measurement of the size of aneurysms. In contrast, it has a very low predictive positive value for the detection of leaks
Assuntos
Buscar no Google
Coleções: Bases de dados nacionais / Espanha Contexto em Saúde: ODS3 - Saúde e Bem-Estar Problema de saúde: Meta 3.4: Reduzir as mortes prematuras devido doenças não transmissíveis Base de dados: IBECS Assunto principal: Tomografia Computadorizada por Raios X / Aneurisma da Aorta Abdominal / Ecocardiografia Doppler em Cores Tipo de estudo: Estudo diagnóstico / Estudo observacional / Estudo prognóstico / Fatores de risco Limite: Humanos Idioma: Espanhol Revista: Angiología Ano de publicação: 2007 Tipo de documento: Artigo Instituição/País de afiliação: Hospital Cínico Universitario de Valladolid/España
Buscar no Google
Coleções: Bases de dados nacionais / Espanha Contexto em Saúde: ODS3 - Saúde e Bem-Estar Problema de saúde: Meta 3.4: Reduzir as mortes prematuras devido doenças não transmissíveis Base de dados: IBECS Assunto principal: Tomografia Computadorizada por Raios X / Aneurisma da Aorta Abdominal / Ecocardiografia Doppler em Cores Tipo de estudo: Estudo diagnóstico / Estudo observacional / Estudo prognóstico / Fatores de risco Limite: Humanos Idioma: Espanhol Revista: Angiología Ano de publicação: 2007 Tipo de documento: Artigo Instituição/País de afiliação: Hospital Cínico Universitario de Valladolid/España
...