Your browser doesn't support javascript.
loading
Osteosíntesis de fracturas del fémur distal con placas LISS / Distal femoral fractures; treatment with less invasive stabilitation system (L. I. S. S.)
Enguita Hualde, A. M; Albareda Albareda, J; Ruiz Ruiz, F. J; Gómez Moreno, R; Seral García, B; Seral Íñigo, F.
Afiliação
  • Enguita Hualde, A. M; Hospital Clínico Universitario Lozano Blesa. Zaragoza. España
  • Albareda Albareda, J; Hospital Clínico Universitario Lozano Blesa. Zaragoza. España
  • Ruiz Ruiz, F. J; Hospital Clínico Universitario Lozano Blesa. Zaragoza. España
  • Gómez Moreno, R; Hospital Clínico Universitario Lozano Blesa. Zaragoza. España
  • Seral García, B; Hospital Clínico Universitario Lozano Blesa. Zaragoza. España
  • Seral Íñigo, F; Hospital Clínico Universitario Lozano Blesa. Zaragoza. España
Arch. Fac. Med. Zaragoza ; 45(3): 55-57, dic. 2005. ilus, tab
Artigo em Es | IBECS | ID: ibc-052875
Biblioteca responsável: ES1.1
Localização: ES1.1 - BNCS
RESUMEN
Las fracturas del fémur distal son complejas en su tratamiento y asocian múltiples complicaciones evolutivas com pseudoartrosis, callos viciosos, gonartrosis o infección secundaria a cirugía abierta agresiva, por lo que han surgido las osteosíntesis mínimamente invasivas dentro de las cuales se sitúa la placa LISS. Analizamos los resultados tras 10 meses de seguimiento de 14 pacientes con fractura del fémur distal tratados con placa LISS. Los tiempos de consolidación no fueron muy divergentes respecto a series mayores, la incidencia de retrasos de consolidación y callos viciosos, baja. No hubo pseudoartrosis, fracasos del material, aflojamientos, infecciones, tromboembolismos ni algodistrofias. Por ello, consideramos que los resultados obtenidos con este implante son satisfactorios
ABSTRACT
The treatment of the distal femoral fractures is difficult in order to the surgery and múltiple complications, like pseudoartrosis,c allus vicious, gonartrosis or infection because open surgery. So that it has arised the minimun invasive system of osteosynthesis like LISS plate. We have assessed outcomes in 14 patients with distal femoral fractures treated with that implant. The mean follow up was 10 months. The times of consolidation was similar than other bigger series of patients and low incidence of delayed consolidation and callus vicious. There has not been any case of pseudoartrosis, failure of implant, loosenin, infections, tromboembolism or algodystrophia, so that considered that we has obtained good

results:

Assuntos
Buscar no Google
Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Procedimentos Cirúrgicos Minimamente Invasivos / Fraturas do Fêmur / Fêmur / Fixação Interna de Fraturas Tipo de estudo: Estudo diagnóstico Limite: Feminino / Humanos / Masculino Idioma: Espanhol Revista: Arch. Fac. Med. Zaragoza Ano de publicação: 2005 Tipo de documento: Artigo Instituição/País de afiliação: Hospital Clínico Universitario Lozano Blesa/España
Buscar no Google
Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Procedimentos Cirúrgicos Minimamente Invasivos / Fraturas do Fêmur / Fêmur / Fixação Interna de Fraturas Tipo de estudo: Estudo diagnóstico Limite: Feminino / Humanos / Masculino Idioma: Espanhol Revista: Arch. Fac. Med. Zaragoza Ano de publicação: 2005 Tipo de documento: Artigo Instituição/País de afiliação: Hospital Clínico Universitario Lozano Blesa/España
...