Prótesis metálicas autoexpandibles versus antrectomía en el tratamiento paliativo del adenocarcinoma obstructivo del antro gástrico / Self-expanding metal stents versus antrectomy for the palliative treatment of obstructive adenocarcinoma of the gastric antrum
Rev. esp. enferm. dig
; 104(4): 185-189, abr. 2012. tab, ilus
Artigo
em Espanhol
| IBECS
| ID: ibc-100191
Biblioteca responsável:
ES1.1
Localização: BNCS
RESUMEN
Introducción:
los pacientes con cáncer gástrico tienen un tumor irresecable hasta en el 40% de los casos. La obstrucción de salida gástrica ocasiona vómito, deshidratación y desnutrición. El objetivo de este estudio fue comparar las prótesis metálicas autoexpandibles con la antrectomia en el tratamiento paliativo del adenocarcinoma obstructivo del antro gástrico.Método:
estudio restrospectivo en pacientes con adenocarcinoma obstructivo del antro gástrico. Los pacientes fueron divididos en dos grupos grupo A) sujetos que fueron tratados mediante prótesis metálica autoexpandible y grupo B) aquellos que fueron tratados mediante antrectomía y gastroyeyunoanastomosis en Y de Roux. Las variables recogidas fueron edad, género, índice de masa corporal, histopatología, estadio clínico (TNM), estado general (escala de Karnofsky), días de estancia intrahospitalaria, necesidad de re-intervención, complicaciones relacionada con el tratamiento y sobrevida.Resultados:
fueron incluidos 39 pacientes, 21 hombres y 18 mujeres. Diecinueve pacientes correspondieron al grupo A y 20 al grupo B. No hubo diferencias estadísticamente significativas con respecto a la edad, índice de masa corporal, calificación de Karnofsky y estadio clínico. El éxito técnico y clínico fue similar en ambos grupos. Hubo diferencia estadísticamente significativa entre ambos grupos, favoreciendo a las prótesis metálicas autoexpandibles en tiempo de inicio de la vía oral (1 ± 0 vs. 4,9 ± 0,6 días, p = 0,0001) y estancia intrahospitalaria (0,94 ± 1,18 vs. 7,8 ± 7,7 días, p = 0,0005). No encontramos diferencia estadísticamente significativa con respecto a la sobrevida entre los dos grupos.Conclusiones:
en pacientes con obstrucción gástrica secundaria a cáncer gástrico avanzado, el tratamiento con prótesis metálicas autoexpandibles proporciona un intervalo mas corto para el inicio de la vía oral, una estancia intrahospitalaria mas corta y una frecuencia de complicaciones menor(AU)ABSTRACT
Background:
gastric cancer patients are first diagnosed with an unresectable tumor in up to 40% of cases. Gastric outlet obstruction causes nausea, vomiting, dehydration and malnutrition. The aim of the study was to compare self-expanding metal stents to antrectomy and Roux-en Y gastrojejunostomy for palliation of obstructive adenocarcinoma of the gastric antrum.Methods:
retrospective study in patients with obstructing cancer of the gastric antrum. Patients were divided into two groups group A, underwent endoscopic placement of self-expanding metal stents and group B underwent surgical treatment with antrectomy and Roux-en Y gastrojejunostomy. Collected Data included age, gender, performance status (Karnofskys score), body mass index, histopathology, clinical stage (TNM classification), technical and clinical success of the procedure, time to oral intake, in-hospital stay, reintervention rate, and complications related to the treatment and survival.Results:
a total of 39 patients with gastric adenocarcinoma were included, 21 male and 18 female. Nineteen patients were assigned to group A and 20 patients to group B. There were no statistically significant differences between groups in regards to age, body mass index, Karnofskys score and clinical stage. The technical and clinical success was similar for both groups. There was a statistically significant difference between groups favoring Self-expanding metal stent in time to oral intake (1 ± 0 vs. 4.9 ± 0.6 days, p = 0.0001) and in-hospital stay (0.94 ± 1.18 vs. 7.8 ± 7.7 days, p = 0.0005). We did not find statistically significant differences with regards to long-term survival.Conclusions:
in patients with malignant gastric outlet obstruction due to gastric cancer, endoscopic palliation with self-expanding metal stents provide a shorter interval to oral intake, shorter inhospital stay and lower rate of complications(AU)
Texto completo:
Disponível
Coleções:
Bases de dados nacionais
/
Espanha
Base de dados:
IBECS
Assunto principal:
Cuidados Paliativos
/
Adenocarcinoma
/
Desidratação
/
Desnutrição
/
Neoplasias Gastrointestinais
Tipo de estudo:
Estudo diagnóstico
/
Estudo observacional
/
Fatores de risco
Aspecto:
Determinantes sociais da saúde
Limite:
Adulto
/
Feminino
/
Humanos
/
Masculino
Idioma:
Espanhol
Revista:
Rev. esp. enferm. dig
Ano de publicação:
2012
Tipo de documento:
Artigo
Instituição/País de afiliação:
Instituto Nacional de Cancerología/México