Monitorización continua de los potenciales evocados visuales corticales mediante electrodos subdurales en la cirugía de la vía óptica posterior. Caso clínico y revisión de la bibliografía / Continuous monitoring of cortical visual evoked potentials by means of subdural electrodes in surgery on the posterior optic pathway. A case report and review of the literature
Torres, Cristina V; Pastor, Jesús; Rocío, Esmeralda; Sola, Rafael G.
Afiliação
  • Torres, Cristina V; Hospital Universitario La Princesa. Servicio de Neurocirugía. Madrid. España
  • Pastor, Jesús; Hospital Clínico San Carlos. Servicio de Neurofisiología Clínica. Madrid. España
  • Rocío, Esmeralda; Hospital Clínico San Carlos. Servicio de Neurofisiología Clínica. Madrid. España
  • Sola, Rafael G; Hospital Universitario La Princesa. Servicio de Neurocirugía. Madrid. España
Rev. neurol. (Ed. impr.) ; 55(6): 343-348, 16 sept., 2012. ilus
Artigo em Espanhol | IBECS | ID: ibc-103512
Biblioteca responsável: ES1.1
Localização: BNCS
RESUMEN
Introducción. La monitorización intraoperatoria de áreas funcionales del lenguaje y motoras está ampliamente difundida,lo que permite minimizar las secuelas postoperatorias y optimizar la resección de lesiones en estas áreas. La monitorización de la corteza visual, sin embargo, no se realiza de forma habitual en la actualidad. La escasa resolución espacial y su sensibilidad a la anestesia son algunas de las dificultades técnicas que disminuyen su utilidad clínica. Se presenta un caso de resección de una lesión occipital bajo anestesia general, con monitorización intraoperatoria de los potenciales evocados visuales (PEV) corticales mediante electrodos subdurales. Caso clínico. Mujer de 50 años, intervenida quirúrgicamente para la resección de una lesión occipital, sugestiva de radionecrosis. Se monitorizaron los PEV mediante administración de luz intermitente a 4,1 Hz y registro con tira subdural en la corteza occipital. Durante la cirugía, se observó disminución progresiva de la amplitud de los PEV corticales cuando superó el 50% de la amplitud basal, por lo que se finalizó la resección. El incremento de la latencia fue inferior al 10% del valor basal. La paciente tuvo una buena evolución postoperatoria, y su función visual no presentó cambios respecto a la basal. Conclusiones. La monitorización de los PEV corticales mediante registros corticales produjo en nuestro caso registros estables y con una buena correlación con la función visual postoperatoria. Los registros corticales directos o con electrodos subdurales permiten conseguir una resolución espacial e intensidad de respuesta adecuadas. Es necesario llevar a cabo estudios con un número mayor de pacientes para obtener conclusiones definitivas (AU)
ABSTRACT
Introduction. Intraoperative monitoring of functional language and motor areas is a commonly used technique which makes it possible to minimise the post-operative sequelae and to perform an optimal resection of lesions in these areas. Monitoring of the visual cortex, however, is not usually carried out nowadays. The scarce spatial resolution and its sensitivity to anaesthesia are some of the technical difficulties that reduce its clinical usefulness. The study reports a case of resection of an occipital lesion under general anaesthetic, with intraoperative monitoring of the cortical visual evoked potentials (VEP) by means of subdural electrodes. Case report. A 50-year-old female who underwent surgery involving the resection of an occipital lesion that was suggestive of radionecrosis. The VEP were monitored by administering flashing light at 4.1 Hz and recording with subdural strip electrodes on the occipital cortex. During the operation, a progressive lowering of the amplitude of the cortical VEP was observed when 50% of the baseline amplitude was exceeded, and thus the resection was finished. The increase in latency was below 10% of the baseline value. The patient recovered well during the post-operative period and her sight did not present any changes with respect to the baseline values. Conclusions. In our case, monitoring the cortical VEP by cortical recordings produced stable recordings with a good correlation with the post-operative visual function. Cortical recordings performed either directly or by means of subdural electrodes make it possible to achieve adequate spatial resolution and response intensity. Further studies need to be conducted with a greater number of patients in order to obtain decisive conclusions (AU)
Assuntos
Buscar no Google
Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Transtornos da Visão / Vias Visuais / Potenciais Evocados Visuais Limite: Feminino / Humanos Idioma: Espanhol Revista: Rev. neurol. (Ed. impr.) Ano de publicação: 2012 Tipo de documento: Artigo Instituição/País de afiliação: Hospital Clínico San Carlos/España / Hospital Universitario La Princesa/España
Buscar no Google
Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Transtornos da Visão / Vias Visuais / Potenciais Evocados Visuais Limite: Feminino / Humanos Idioma: Espanhol Revista: Rev. neurol. (Ed. impr.) Ano de publicação: 2012 Tipo de documento: Artigo Instituição/País de afiliação: Hospital Clínico San Carlos/España / Hospital Universitario La Princesa/España
...