Valoración del grado de coagulación y del factor anti-Xa al introducir el dializador AN69ST® con heparina impregnada / Evaluation of coagulation and anti-Xa factor using a heparin-coated AN69ST® dialyser
Nefrología (Madr.)
; 32(5): 605-612, sept.-oct. 2012. ilus, tab
Artigo
em Espanhol
| IBECS
| ID: ibc-106150
Biblioteca responsável:
ES1.1
Localização: BNCS
RESUMEN
Introducción:
Los sistemas de hemodiálisis tienen capacidad trombogénica, por lo que se utiliza de forma rutinaria la anticoagulación. Su prescripción no se encuentra exenta de riesgos, a pesar de lo cual las recomendaciones respecto a la dosis pautada siguen basándose en criterios muy diversos.Métodos:
Se realizó un estudio experimental aleatorizado y cruzado. Seis pacientes realizaron seis sesiones de hemodiafiltración posdilución con el dializador de polisulfona HF80® y anticoagulación habitual con nadroparina, y seis sesiones con el dializador AN69ST® de poliacrilonitrilo con una cubierta de heparina sin el uso de anticoagulación sistémica. Evaluamos cada hora el grado de coagulación del dializador y del circuito extracorpóreo mediante una escala visual y las variaciones en los parámetros de coagulación, entre los que se incluyó el factor anti-Xa. Nuestro objetivo primario fue valorar las variaciones en la actividad del factor anti-Xa en ausencia de diferencias en la tasa de coagulación masiva entre los dos grupos.Resultados:
No se coaguló el dializador de forma completa o grado 4 en ninguna de las 36 sesiones realizadas con cada dializador. Se produjo una coagulación parcial del dializador inferior del 25% (grado 1-2) en 32 (88,9%) sesiones con AN69ST® y 35 (97,2%) con el dializador habitual, y superior del 25% (grado 3-4) en 4 (11,1%) sesiones con AN69ST® y en 1 (2,8%) sesión con el dializador con heparina. La coagulación del atrapaburbujas arterial no fue superior al 25% (grados 3 y 4) en ninguna de las sesiones estudiadas, y la cámara venosa en sólo 1 (2,8%) sesión con el dializador habitual y 3 (8,4%) con AN69ST® sin diferencias entre los dos dializadores. El (..) (AU)ABSTRACT
Background:
Haemodialysis systems are potentially thrombogenic, so anticoagulation is routinely used. Its prescription involves certain risks, despite which the recommendations regarding dosage are still based on very disparate criteria.Methods:
We performed a randomised, crossed pilot study. Six patients underwent six sessions of post-dilution haemodiafiltration with a polysulfone HF80® dialyser and standard anticoagulation with nadroparin, and six sessions with heparincoated poliacrylonitrile AN69ST® membrane without the administration of systemic anticoagulation therapy. The coagulation level of the dialyser and extracorporeal circuit was evaluated every hour using a visual scale along with variation in clotting parameters such as anti-Xa factor. Our primary objective was to assess anti-Xa activity in the absence of differences in the rate of massive coagulation between the two groups.Results:
No complete or grade 4 dialyser clotting occurred in any of the 36 sessions with either dialyser. Partial clotting of the dialyser occurred below 25% (grade 1-2) in 32 (88.9%) AN69ST® sessions and 35 (97.2%) sessions using the standard dialyser, and partial clotting surpassed 25% (grade 3-4) in 4 (11.1%) AN69ST® sessions and 1 (2.8%) dialysis session with heparin. Arterial chamber blood clotting did not surpass 25% (grade 3 and 4) in any of the studied sessions, and venous chamber coagulation occurred in only 1 (2.8%) session with the usual dialyser and in 3 (8.4%) sessions with the AN69ST®, with no significant differences between the two (..) (AU)
Texto completo:
Disponível
Coleções:
Bases de dados nacionais
/
Espanha
Contexto em Saúde:
Agenda de Saúde Sustentável para as Américas
Problema de saúde:
Objetivo 9: Redução de doenças não transmissíveis
Base de dados:
IBECS
Assunto principal:
Soluções para Diálise
/
Diálise Renal
/
Hemodiafiltração
/
Insuficiência Renal Crônica
Tipo de estudo:
Ensaio clínico controlado
/
Guia de prática clínica
Limite:
Humanos
Idioma:
Espanhol
Revista:
Nefrología (Madr.)
Ano de publicação:
2012
Tipo de documento:
Artigo
Instituição/País de afiliação:
Hospital General de Castellón/s. p