Resultados de un implante de poliuretano para el tratamiento del dolor persistente de rodilla tras meniscectomía parcial con un mínimo de dos años de seguimiento / Results of polyurethane implant for persistent knee pain after partial meniscectomy with a minimum of two years follow-up
Martín-Hernández, C; Ranera-García, M; Díaz-Martínez, J. V; Muniesa-Herrero, M. P; Floría-Arnal, L. J; Osca-Guadalajara, M; García-Aguilera, D.
Afiliação
  • Martín-Hernández, C; Hospital Obispo Polanco. Teruel. España
  • Ranera-García, M; Hospital Obispo Polanco. Teruel. España
  • Díaz-Martínez, J. V; Hospital Obispo Polanco. Teruel. España
  • Muniesa-Herrero, M. P; Hospital Obispo Polanco. Teruel. España
  • Floría-Arnal, L. J; Hospital Obispo Polanco. Teruel. España
  • Osca-Guadalajara, M; Hospital Obispo Polanco. Teruel. España
  • García-Aguilera, D; Hospital Obispo Polanco. Teruel. España
Rev. esp. cir. ortop. traumatol. (Ed. impr.) ; 59(1): 44-51, ene.-feb. 2015. tab, ilus
Artigo em Espanhol | IBECS | ID: ibc-132377
Biblioteca responsável: ES1.1
Localização: BNCS
RESUMEN
Objetivo. Evaluar los resultados de un implante de poliuretano en 10 pacientes con dolor persistente tras meniscectomía parcial. Material y métodos. Estudio prospectivo descriptivo de 10 pacientes que fueron intervenidos para colocación artroscópica de un implante meniscal de poliuretano. Se realizó evaluación funcional, de resonancia magnética y radiología simple antes de la intervención, a los 6 meses, un año, y en el seguimiento final con un mínimo de dos años. La evaluación clínica incluyó las escalas de Lysholm, KOOS y EVA. En resonancia magnética (RM) se evaluó la morfología y la intensidad de la señal del implante según los criterios de Genovese et al. Resultados. Se encontraron diferencias significativas entre la media de puntuación de Lysholm antes de la cirugía (63,5 puntos), a los 6 meses (76,8 puntos) (p = 0,001), al año (83,3 puntos) (p < 0,001) y al final del seguimiento (84,4 puntos) (p < 0,001). En la puntuación del KOOS se hallaron diferencias significativas entre las medias en el preoperatorio (64,23 puntos) y 6 meses (73,66 puntos) (p = 0,001), un año (81,39 puntos) (p < 0,001) y el seguimiento final (83,34 puntos) (p < 0,001). Los valores promedio de la EVA fueron de 5,7 puntos en el preoperatorio, 3,6 puntos a los 6 meses (p < 0,001), 1,9 puntos al año (p < 0,001) y 1,9 puntos al final del seguimiento (p < 0,001). La radiología mostró cambios degenerativos en un caso. En la RM, el tamaño del implante y la intensidad de la señal de RM disminuyeron progresivamente, no llegando a alcanzar nunca los de un menisco normal. Conclusiones. Veinticuatro meses después de la cirugía se ha encontrado una mejora significativa en todos los parámetros clínicos, salvo en un paciente que precisó reintervención. El tamaño del implante se redujo y en ningún caso se alcanzó una imagen de RM similar a la de un menisco normal. El procedimiento demostró ser seguro y útil para el tratamiento del dolor persistente tras meniscectomía (AU)
ABSTRACT
Purpose. To present the results of a polyurethane meniscal scaffold implant in 10 patients with persistent pain after meniscectomy. Methods. Prospective, descriptive study of ten patients who underwent arthroscopic implantation of a polyurethane meniscal scaffold. Functional, MRI, and radiography assessment was performed pre-operatively and at 6-months, 1-year, and a final follow-up at a minimum of two years. Clinical evaluation included Lysholm score, KOOS and VAS. The MRI morphology and signal intensity of the implant were evaluated according to the criteria of Genovese et al. Results. Statistically significant differences were found between the mean Lysholm score before surgery (63.5 points), and that at 6 months (76.8 points) (p = .001), one year (83.3 points) (p < .001) and final follow-up (84.4 points) (p < .001). KOOS showed significant differences between before surgery (64.23 points), 6 months (73.66 points) (p = .001), one year (81.39 points) (p < .001) and final follow-up (83.34 points) (p < .001). The mean values for VAS were 5.7 points in the pre-operative evaluation, 3.6 points at 6 months-follow-up (p < .001), 1.9 points at one year (p < .001), and 1.9 points at final follow-up (p < .001). Radiology showed degenerative changes in one case. In MRI, the size of the implant and the intensity of the MRI signal gradually decreased, but it never changed to that of a normal meniscus. Conclusion. A significant improvement was found in all the clinical parameters 24 months after the surgery, except in one patient who underwent furher surgery. The scaffold reduced its size and but never achieved an MRI image similar to that of a normal meniscus (AU)
Assuntos
Buscar no Google
Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Aparelhos Ortopédicos / Artroscopia / Procedimentos Ortopédicos / Joelho / Prótese do Joelho Tipo de estudo: Estudo de avaliação / Estudo observacional Limite: Adolescente / Adulto / Feminino / Humanos / Masculino Idioma: Espanhol Revista: Rev. esp. cir. ortop. traumatol. (Ed. impr.) Ano de publicação: 2015 Tipo de documento: Artigo Instituição/País de afiliação: Hospital Obispo Polanco/España
Buscar no Google
Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Aparelhos Ortopédicos / Artroscopia / Procedimentos Ortopédicos / Joelho / Prótese do Joelho Tipo de estudo: Estudo de avaliação / Estudo observacional Limite: Adolescente / Adulto / Feminino / Humanos / Masculino Idioma: Espanhol Revista: Rev. esp. cir. ortop. traumatol. (Ed. impr.) Ano de publicação: 2015 Tipo de documento: Artigo Instituição/País de afiliação: Hospital Obispo Polanco/España
...