Your browser doesn't support javascript.
loading
Evaluación de la reproducibilidad de un protocolo de resonancia magnética dinámica para el estudio farmacocinético de los tumores de mama / Evaluation of the reproducibility of a protocol for the pharmacokinetic study of breast tumors by dynamic magnetic resonance imaging
Etxano, J; García-Lallana Valbuena, A; Antón Ibáñez, I; Elizalde, A; Pina, L; García-Foncillas, J; Boni, V.
Afiliação
  • Etxano, J; Clínica Universidad de Navarra. Departamento de Radiología. Pamplona. España
  • García-Lallana Valbuena, A; Hospital San Juan de Dios. España
  • Antón Ibáñez, I; Progenika Biopharma S.A. España
  • Elizalde, A; Clínica Universidad de Navarra. Departamento de Radiología. Pamplona. España
  • Pina, L; Clínica Universidad de Navarra. Departamento de Radiología. Pamplona. España
  • García-Foncillas, J; Clínica Universidad de Navarra. Departamento de Oncología. Pamplona. España
  • Boni, V; Clínica Universidad de Navarra. Departamento de Oncología. Pamplona. España
Radiología (Madr., Ed. impr.) ; 57(1): 44-49, ene.-feb. 2015. tab, ilus
Artigo em Espanhol | IBECS | ID: ibc-136634
Biblioteca responsável: ES1.1
Localização: BNCS
RESUMEN
Objetivo. Evaluar la reproducibilidad de un protocolo de resonancia magnética dinámica (RM-DC) con contraste para el estudio farmacocinético de los tumores de mama. Material y métodos. Estudio prospectivo realizado entre octubre y diciembre de 2009, que incluyó 12 pacientes con cáncer de mama infiltrante en estadios ii-iii sin tratamiento previo. Este trabajo fue aprobado por el Comité de Ética de Investigación de nuestro centro. A las 12 pacientes se les realizó 2 RM-DC en 2 días consecutivos con un protocolo de alta resolución temporal (21 adquisiciones/minuto). Se analizaron por separado los datos obtenidos en un ROI trazado alrededor del diámetro tumoral mayor (ROI 1) y otro que abarcaba la zona de mayor intensidad de Ktrans de la lesión (ROI 2). Se emplearon pruebas estadísticas paramétricas y no paramétricas para estudiar la reproducibilidad y concordancia de las principales variables farmacocinéticas (Ktrans, Kep, Ve y AUC90). Resultados. Las correlaciones fueron muy altas (r > 0,80; p < 0,01) en todas las variables del ROI 1, y altas (r = 0,70-0,80; p < 0,01) en todas las del ROI 2, excepto en Ve tanto en el ROI 1 (r = 0,44; p = 0,07) como en el ROI 2 (r = 0,13; p = 0,235). No hubo diferencias estadísticamente significativas entre los 2 estudios para los valores obtenidos de Ktrans, Kep y AUC90 (p > 0,05 para todas ellas), pero sí que las hubo para Ve en el ROI 2 (p = 0,008). Conclusión. El protocolo de alta resolución temporal de RM-DC de nuestro centro es muy reproducible para las principales constantes farmacocinéticas de los tumores de mama (AU)
ABSTRACT
Objective. To evaluate the reproducibility of a protocol for dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) for the pharmacokinetic study of breast tumors. Material and methods. We carried out this prospective study from October 2009 through December 2009. We studied 12 patients with stage ii-iii invasive breast cancer without prior treatment. Our center's research ethics committee approved the study. The 12 patients underwent on two consecutive days DCE-MRI with a high temporal resolution protocol (21 acquisitions/minute). The data obtained in an ROI traced around the largest diameter of the tumor (ROI 1) and in another ROI traced around the area of the lesion's highest Ktrans intensity (ROI 2) were analyzed separately. We used parametric and nonparametric statistical tests to study the reproducibility and concordance of the principal pharmacokinetic variables (Ktrans, Kep, Ve and AUC90). Results. The correlations were very high (r>.80; P<.01) for all the variables for ROI 1 and high (r=.70-.80; P<.01) for all the variables for ROI 2, with the exception of Ve both in ROI 1 (r=.44; P=.07) and in ROI 2 (r=.13; P=.235). There were no statistically significant differences between the two studies in the values obtained for Ktrans, Kep and AUC90 (P>.05 for each), but there was a statistically significant difference between the two studies in the values obtained for Ve in ROI 2 (P=.008). Conclusions. The high temporal resolution protocol for DCE-MRI used at out center is very reproducible for the principal pharmacokinetic constants of breast (AU)
Assuntos
Buscar no Google
Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Neoplasias da Mama / Imageamento por Ressonância Magnética / Farmacocinética / Espectroscopia de Ressonância Magnética / Ultrassonografia Mamária Tipo de estudo: Estudo de avaliação / Guia de prática clínica / Estudo observacional Aspecto: Aspectos éticos Limite: Adulto / Feminino / Humanos Idioma: Espanhol Revista: Radiología (Madr., Ed. impr.) Ano de publicação: 2015 Tipo de documento: Artigo Instituição/País de afiliação: Clínica Universidad de Navarra/España / Hospital San Juan de Dios/España / Progenika Biopharma S.A/España
Buscar no Google
Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Neoplasias da Mama / Imageamento por Ressonância Magnética / Farmacocinética / Espectroscopia de Ressonância Magnética / Ultrassonografia Mamária Tipo de estudo: Estudo de avaliação / Guia de prática clínica / Estudo observacional Aspecto: Aspectos éticos Limite: Adulto / Feminino / Humanos Idioma: Espanhol Revista: Radiología (Madr., Ed. impr.) Ano de publicação: 2015 Tipo de documento: Artigo Instituição/País de afiliação: Clínica Universidad de Navarra/España / Hospital San Juan de Dios/España / Progenika Biopharma S.A/España
...