Rendimiento diagnóstico y pronóstico del registro Holter de 24horas en pacientes con síncope / Diagnostic and prognostic efficiency of 24-hour Holter monitoring in patients with syncope
Med. clín (Ed. impr.)
; Med. clín (Ed. impr.);147(4): 148-150, ago. 2016. tab
Article
em Es
| IBECS
| ID: ibc-154590
Biblioteca responsável:
ES1.1
Localização: BNCS
RESUMEN
Antecedentes y objetivo: El síncope es una entidad frecuente y con un diagnóstico complejo. El rendimiento del Holter-ECG 24h en este contexto no está bien definido. Nuestro objetivo fue evaluar su capacidad diagnóstica y pronóstica en estos pacientes. Pacientes y método: Estudio retrospectivo de 6.006 pacientes consecutivos remitidos a nuestra unidad para la realización de Holter-ECG 24h por síncope. Se registraron los hallazgos diagnósticos y aquellos hallazgos anormales potencialmente relacionados con una causa arrítmica de síncope. El objetivo pronóstico fue un combinado de muerte o necesidad de implante de dispositivo (marcapasos o desfibrilador implantable) a un año. Resultados: En total, 242 pacientes (4%) presentaron hallazgos diagnósticos y 472 (7,9%) tuvieron algún hallazgo anormal. En 328 casos fue necesario el implante de un dispositivo a un año, pero hasta un 66% de estos enfermos no tenían ningún hallazgo relevante en el Holter. Un total de 564 pacientes presentaron el episodio combinado, incluyendo el 36,8% de pacientes con hallazgos diagnósticos y el 8,2% sin hallazgos diagnósticos. Conclusiones: El Holter-ECG 24h presenta un rendimiento diagnóstico y pronóstico limitados en pacientes no seleccionados con síncope (AU)
ABSTRACT
Background and objective: Syncope is a common condition and complex to diagnose. The yield of the 24h-Holter ECG in this context has not been clearly defined. The aim of this study was to evaluate its diagnostic and prognostic capacity in these patients. Patients and method: Retrospective study of 6,006 consecutive patients sent to our unit for 24h-Holter ECG monitoring for syncope. We registered the diagnostic findings and abnormal findings potentially related to an arrhythmic cause of syncope. The prognostic endpoint was a combination of death or the need for device implantation (pacemaker or defibrillator) within one year. Results: 242 patients (4%) presented diagnostic findings and 472 (7.9%) had some abnormal findings. In 328 cases device implantation was necessary within one year, but up to 66% of these patients did not have any relevant findings on the Holter monitoring. A total of 564 patients presented the combined event, including 36.8% of patients with diagnostic findings and 8.2% without them. Conclusions: 24h-Holter ECG monitoring presents a limited diagnostic and prognostic yield in unselected patients with syncope (AU)
Buscar no Google
Coleções:
06-national
/
ES
Base de dados:
IBECS
Assunto principal:
Síncope
/
Eletrocardiografia Ambulatorial
/
Cardiopatias
Tipo de estudo:
Diagnostic_studies
/
Evaluation_studies
/
Observational_studies
/
Prognostic_studies
/
Risk_factors_studies
Limite:
Humans
Idioma:
Es
Revista:
Med. clín (Ed. impr.)
Ano de publicação:
2016
Tipo de documento:
Article