Your browser doesn't support javascript.
loading
Utilidad del lavado broncoalveolar en el diagnóstico de enfermedades relacionadas con el amianto / Utility of Bronchoalveolar Lavage for the Diagnosis of Asbestos-Related Diseases
Cruz, María Jesús; Curull, Victor; Pijuan, Lara; Álvarez-Simón, Daniel; Sánchez-Font, Albert; Gracia, Javier de; Culebras, Mario; Ferrer, Jaume.
Afiliação
  • Cruz, María Jesús; Hospital Universitario Vall d’Hebron. Servicio de Neumología. Barcelona. España
  • Curull, Victor; Universitat Autónoma de Barcelona. Department de Medicina. Barcelona. España
  • Pijuan, Lara; Hospital del Mar. Servicio de Neumología. Barcelona. España
  • Álvarez-Simón, Daniel; Hospital Universitario Vall d’Hebron. Servicio de Neumología. Barcelona. España
  • Sánchez-Font, Albert; Ciber Enfermedades Respiratorias (CibeRes). Barcelona. España
  • Gracia, Javier de; Hospital Universitario Vall d’Hebron. Servicio de Neumología. Barcelona. España
  • Culebras, Mario; Hospital Universitario Vall d’Hebron. Servicio de Neumología. Barcelona. España
  • Ferrer, Jaume; Hospital Universitario Vall d’Hebron. Servicio de Neumología. Barcelona. España
Arch. bronconeumol. (Ed. impr.) ; 53(6): 318-323, jun. 2017. tab, graf
Artigo em Espanhol | IBECS | ID: ibc-163656
Biblioteca responsável: ES1.1
Localização: BNCS
RESUMEN

Introducción:

El análisis del lavado broncoalveolar (LBA) se ha propuesto como técnica objetiva para certificar la exposición a amianto. Sin embargo, la fiabilidad y rendimiento diagnóstico de este procedimiento diagnóstico no se han analizado en España. El propósito de este estudio fue evaluar la utilidad del análisis de cuerpos de amianto (CA) en el LBA para el diagnóstico de enfermedades relacionadas con el amianto (ERA).

Métodos:

Se analizaron muestras de LBA de 72 pacientes (66 varones, edad media de 66 años) sometidos a broncoscopia. También se analizó el tejido pulmonar de 23 de estos pacientes. La exposición al amianto se evaluó a partir de la anamnesis y la revisión de las historias clínicas de los pacientes. Las muestras de LBA y de tejido pulmonar se procesaron, y la cantidad de CA se determinó mediante microscopia óptica. El valor umbral aceptado para diagnosticar una enfermedad relacionada con el amianto fue de 1 CA/ml de LBA o 1.000 CA/g de tejido seco.

Resultados:

Treinta y nueve pacientes refirieron exposición a amianto. En 13 (33%) de estos pacientes, los niveles de CA fueron superiores a 1 CA/ml de LBA. De los 33 pacientes no expuestos, los valores de CA fueron superiores a 1 CA/ml de LBA en 5 casos (15%). La diferencia entre los niveles de CA de los pacientes expuestos y los no expuestos fue significativa (p = 0,006). La curva ROC indicó que el nivel de 0,5 CA/ml de LBA era el que alcanzaba mayor sensibilidad (46%), con un 83% de especificidad. El grado de correlación entre los niveles de CA en el LBA y el tejido pulmonar fue de 0,633 (p = 0,002).

Conclusiones:

El estudio del LBA ofrece una prueba objetiva de la exposición a amianto. La buena correlación observada entre los recuentos de CA en el LBA y en el tejido pulmonar indica la validez de ambas técnicas para analizar el contenido de amianto (AU)
ABSTRACT

Introduction:

Bronchoalveolar lavage (BAL) analysis has been proposed as an objective technique for confirming asbestos exposure. However, the reliability and diagnostic yield of this procedure has not been studied in Spain. The aim of this study was to assess the usefulness of the analysis of asbestos bodies (AB) in bronchoalveolar lavage (BAL) for the diagnosis of asbestos-related diseases (ARD).

Methods:

BAL samples from 72 patients (66 male, mean age 66 years) undergoing bronchoscopy were analyzed. Lung tissue from 23 of these patients was also analyzed. Asbestos exposure was assessed by anamnesis and a review of the patient's medical records. BAL and lung samples were processed and AB count was determined by light microscopy. The accepted threshold value to diagnose asbestos-related diseases was 1 AB/ml BAL or 1000 AB/gr dry tissue.

Results:

Thirty-nine patients reported exposure to asbestos. Of these, 13 (33%) presented AB values above 1 AB/ml BAL. In the 33 non-exposed patients, 5 (15%) presented AB values above 1 AB/ml BAL. There was a significant difference between the AB levels of exposed and non-exposed patients (P = .006). The ROC curve showed that a value of 0.5 AB/ml BAL achieved the most satisfactory sensitivity, 46%, and a specificity of 83%. The correlation between AB levels in BAL and lung was 0.633 (P = .002).

Conclusions:

BAL study provides objective evidence of exposure to asbestos. The good correlation between the AB counts in BAL and lung tissue indicates that both techniques are valid for the analysis of asbestos content (AU)
Assuntos

Texto completo: Disponível Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Amianto / Asbestose / Líquido da Lavagem Broncoalveolar / Neoplasias Pulmonares Tipo de estudo: Estudo diagnóstico / Estudo prognóstico / Estudo de rastreamento Limite: Humanos Idioma: Espanhol Revista: Arch. bronconeumol. (Ed. impr.) Ano de publicação: 2017 Tipo de documento: Artigo Instituição/País de afiliação: Ciber Enfermedades Respiratorias (CibeRes)/España / Hospital Universitario Vall d’Hebron/España / Hospital del Mar/España / Universitat Autónoma de Barcelona/España

Texto completo: Disponível Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Amianto / Asbestose / Líquido da Lavagem Broncoalveolar / Neoplasias Pulmonares Tipo de estudo: Estudo diagnóstico / Estudo prognóstico / Estudo de rastreamento Limite: Humanos Idioma: Espanhol Revista: Arch. bronconeumol. (Ed. impr.) Ano de publicação: 2017 Tipo de documento: Artigo Instituição/País de afiliação: Ciber Enfermedades Respiratorias (CibeRes)/España / Hospital Universitario Vall d’Hebron/España / Hospital del Mar/España / Universitat Autónoma de Barcelona/España
...