Your browser doesn't support javascript.
loading
Usefulness of the conicity index together with the conjoint use of adipocytokines and nutritional-inflammatory markers in hemodialysis patients
Ruperto, Mar; Barril, Guillermina; Sánchez-Muniz, Francisco J.
Afiliação
  • Ruperto, Mar; Universidad Complutense de Madrid. Facultad de Farmacia. Departamento de Nutrición y Bromatología I (Nutrición). Madrid. Spain
  • Barril, Guillermina; Hospital Universitario La Princesa. Servicio de Nefrología. Madrid. Spain
  • Sánchez-Muniz, Francisco J; Universidad Complutense de Madrid. Facultad de Farmacia. Departamento de Nutrición y Bromatología I (Nutrición). Madrid. Spain
J. physiol. biochem ; 73(1): 67-75, feb. 2017. tab, graf
Artigo em Inglês | IBECS | ID: ibc-168394
Biblioteca responsável: ES1.1
Localização: BNCS
ABSTRACT
Abdominal fat has been recognized as the most hormonally active tissue secreting a variety of adipocytokines and, therefore, potentially contributing to inflammation. The conicity index (Cindex) has been considered a valuable indicator of central obesity. This study aims to relate plasma concentrations of leptin, adiponectin, interleukin-6 (IL-6), and serum C-reactive protein (CRP) with Cindex values in hemodialysis (HD) patients. Cross-sectional study in 45 HD patients (55.6 % men; DM 20 %; mean age, 68.1 year). Cindex and nutritional-inflammatory markers were used for the abdominal fat depot assessment. Patients were classified as having a low or high median Cindex (MCindex) low group (men, <1.39; women, <1.33) and high group (men, ≥1.39; women, ≥1.33). A combination of plasma leptin, IL-6, adiponectin, and CRP was used to design an inflammatory index (Iindex) while a protein-energy wasting index (PEWindex) was calculated from the Iindex plus the malnutrition-inflammation score (MIS). Waist circumference (WC) and Cindex but not BMI were significantly higher in men than in women (p < 0.01). The MCindex was significantly associated with the adipocytokine profile (CRP, leptin, and adiponectin). Patients with a high MCindex had a higher Iindex and PEWindex (p < 0.01). ROC curve analyses measured by area under the curve (AUC) were 0.69 and 0.68 (p < 0.05), for the Cindex and MCindex, respectively, demonstrating the usefulness of the Cindex as an abdominal fat mass biomarker able for wasting-inflamed HD patients. These findings in HD patients underscore the importance of incorporating the evaluation of one abdominal fat indicator, such as the Cindex and an inflammatory biomarker such as the IL-6 and CRP, in substitution of the BMI, in current clinical practice (AU)
RESUMEN
No disponible
Assuntos
Buscar no Google
Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Diálise Renal / Desnutrição Proteico-Calórica / Insuficiência Renal Crônica / Adipocinas / Obesidade Abdominal Tipo de estudo: Estudo observacional / Estudo prognóstico / Fatores de risco Limite: Idoso / Feminino / Humanos / Masculino Idioma: Inglês Revista: J. physiol. biochem Ano de publicação: 2017 Tipo de documento: Artigo Instituição/País de afiliação: Hospital Universitario La Princesa/Spain / Universidad Complutense de Madrid/Spain
Buscar no Google
Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Diálise Renal / Desnutrição Proteico-Calórica / Insuficiência Renal Crônica / Adipocinas / Obesidade Abdominal Tipo de estudo: Estudo observacional / Estudo prognóstico / Fatores de risco Limite: Idoso / Feminino / Humanos / Masculino Idioma: Inglês Revista: J. physiol. biochem Ano de publicação: 2017 Tipo de documento: Artigo Instituição/País de afiliação: Hospital Universitario La Princesa/Spain / Universidad Complutense de Madrid/Spain
...