Your browser doesn't support javascript.
loading
¿Eco-FAST o tomografía computarizada multidetectora en el paciente hemodinámicamente inestable tras traumatismo de urgencias? / Focused assessment with sonography for trauma (FAST) versus multidetector computed tomography in hemodynamically unstable emergency patients
Fornell Pérez, R.
Afiliação
  • Fornell Pérez, R; Complejo Hospitalario Universitario Insular Materno-Infantil. Servicio de Radiodiagnóstico. Las Palmas de Gran Canaria. España
Radiología (Madr., Ed. impr.) ; 59(6): 531-534, nov.-dic. 2017. tab
Artigo em Espanhol | IBECS | ID: ibc-168590
Biblioteca responsável: ES1.1
Localização: BNCS
RESUMEN
Estudio tipo CAT (Critically Appraised Topics) que tiene como objetivo valorar el grado de evidencia científica que apoya la realización de eco-FAST (Focused Assessment with Sonography for Trauma) o tomografía computarizada multidetectora en los pacientes del servicio de urgencias hemodinámicamente inestables tras traumatismo. Se realizó una búsqueda eficiente en la bibliografía y se encontraron varios artículos recientes de alto nivel de evidencia. Se llegó a la conclusión de que se acepta el uso de la eco-FAST como prueba de imagen inicial en el paciente hemodinámicamente inestable, aunque su rendimiento es limitado en determinadas circunstancias. La realización de tomografía computarizada multidetectora debe valorarse dependiendo del grado de inestabilidad y de la distancia que hay que recorrer. Sin embargo, existen pocas referencias que valoren la aproximación de los equipos de tomografía a las salas de urgencia (AU)
ABSTRACT
This critically appraised topic (CAT) study aims to evaluate the quality and extent of the scientific evidence that supports the use of focused assessment with sonography for trauma (FAST) versus multidetector computed tomography (MDCT) in hemodynamically unstable trauma patients in the emergency room. An efficient search of the literature yielded several recent articles with a high level of evidence. The CAT study concludes that FAST is an acceptable initial imaging test in hemodynamically unstable patients, although its performance is limited in certain circumstances. The decision whether to use MDCT should be determined by evaluating the patient's degree of instability and the distance to the MDCT scanner. Nevertheless, few articles address the question of the distance to MDCT scanners in emergency departments (AU)
Assuntos
Buscar no Google
Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Choque / Traumatismo Múltiplo / Tomografia Computadorizada Multidetectores Limite: Humanos Idioma: Espanhol Revista: Radiología (Madr., Ed. impr.) Ano de publicação: 2017 Tipo de documento: Artigo Instituição/País de afiliação: Complejo Hospitalario Universitario Insular Materno-Infantil/España
Buscar no Google
Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Choque / Traumatismo Múltiplo / Tomografia Computadorizada Multidetectores Limite: Humanos Idioma: Espanhol Revista: Radiología (Madr., Ed. impr.) Ano de publicação: 2017 Tipo de documento: Artigo Instituição/País de afiliação: Complejo Hospitalario Universitario Insular Materno-Infantil/España
...