Evaluación del panel gastrointestinal xTAG(R)-GPP de Luminex en el diagnóstico de las gastroenteritis agudas / Evaluation of the Luminex xTAG(R)-GPP (Gastrointestinal Pathogen Panel) in the diagnosis of diseases with acute diarrhoea
Enferm. infecc. microbiol. clín. (Ed. impr.)
; 35(9): 574-577, nov. 2017. tab
Artigo
em Espanhol
| IBECS
| ID: ibc-168884
Biblioteca responsável:
ES1.1
Localização: BNCS
RESUMEN
Introducción:
La mayoría de laboratorios de microbiología utilizan diferentes técnicas para el diagnóstico de las infecciones gastrointestinales. Algunas requieren hasta 72 h para obtener resultados definitivos. Material ymétodos:
El panel gastrointestinal de Luminex (xTAG-GPP, Luminex Molecular Diagnostics, Toronto, Canadá) se trata de un ensayo cualitativo multiplex rápido y sensible capaz de detectar e identificar simultáneamente los 15 patógenos más frecuentes causantes de gastroenteritis. Nuestro objetivo ha sido evaluar este panel multiplex comparándolo con los métodos habituales empleados en nuestro laboratorio.Resultados:
Se analizaron 225 muestras de heces. A través de los métodos convencionales fueron 74 las muestras positivas (32,9%). A través de Luminex fueron 137 las muestras positivas (60,9%).Conclusión:
El uso del panel gastrointestinal de Luminex puede mejorar el diagnóstico de las infecciones gastrointestinales principalmente porque proporciona resultados en menos de 8 h. Determinados microorganismos deben interpretarse con precaución y basándose en datos clínicos y epidemiológicos del paciente (AU)ABSTRACT
Introduction:
Most Microbiology laboratories use different techniques for the diagnosis of gastrointestinal infections. Some of which require at least 72 hours to obtain final results. Material andMethods:
The gastrointestinal panel Luminex (xTAG-GPP, Luminex Molecular Diagnostics, Toronto, Canada) is a qualitative multiplex fast and sensitive assay able to detect and to identify the 15 most common pathogens causing gastrointestinal infection simultaneously. We evaluated this multiplex panel comparing it with conventional methods used in our laboratory.Results:
We analyzed 225 samples of feces. Through the conventional methods were positive 74 samples (32.9%). Through the Luminex method were positive 137 samples (60.9%).Conclusions:
The use of the xTAG(R) GPP system in Clinical Microbiology can improve the diagnosis of gastrointestinal infectious because it provides results in less than 8 hours. Some pathogens should be applied with caution and should be interpreted based on the patients clinical data (AU)
Texto completo:
Disponível
Coleções:
Bases de dados nacionais
/
Espanha
Contexto em Saúde:
Doenças Negligenciadas
Problema de saúde:
Diarreia
/
Doenças Negligenciadas
/
Zoonoses
Base de dados:
IBECS
Assunto principal:
Fezes
/
Gastroenterite
/
Enteropatias
Tipo de estudo:
Estudo diagnóstico
/
Estudo prognóstico
/
Pesquisa qualitativa
Limite:
Humanos
Idioma:
Espanhol
Revista:
Enferm. infecc. microbiol. clín. (Ed. impr.)
Ano de publicação:
2017
Tipo de documento:
Artigo
Instituição/País de afiliação:
Consorcio Hospital General Universitario de Valencia/España