Your browser doesn't support javascript.
loading
Evolución radiológica de las fracturas inestables toracolumbares sin clínica neurológica tratadas mediante cirugía percutánea / Radiological outcomes of unstable thoraco-lumbar fractures without neurological deficit treated through percutaneous surgery
Lorente, Rafael; Lorente, Alejandro; Rosa, Bárbara; Palacios, Pablo; Barrios, Carlos.
Afiliação
  • Lorente, Rafael; Hospital Universitario Infanta Cristina. Servicio de Traumatología y Cirugía Ortopédica. Badajoz. España
  • Lorente, Alejandro; Hospital Universitario Ramón y Cajal. Servicio de Traumatología y Cirugía Ortopédica. Madrid. España
  • Rosa, Bárbara; Hospital de Vila Franca de Xira. Servicio de Traumatología y Cirugía Ortopédica. Vila Franca de Xira. Portugal
  • Palacios, Pablo; Hospital Universitario Madrid Norte Sanchinarro. Servicio de Traumatología y Cirugía Ortopédica. Madrid. España
  • Barrios, Carlos; Instituto Universitario de Investigación en Enfermedades Músculo-Esqueléticas. Valencia. España
Neurocirugía (Soc. Luso-Esp. Neurocir.) ; 29(2): 57-63, mar.-abr. 2018. tab, graf
Artigo em Espanhol | IBECS | ID: ibc-171430
Biblioteca responsável: ES1.1
Localização: BNCS
RESUMEN

Objetivo:

Analizar la evolución radiológica a largo plazo de las fracturas inestables torácicas y lumbares tratadas mediante cirugía percutánea. Material y

métodos:

Serie retrospectiva de una serie de casos con fracturas inestables torácicas y lumbares sin clínica neurológica tratadas mediante cirugía percutánea entre el 2010 y 2015 en 3 hospitales diferentes. Se midieron 6 parámetros radiológicos anualmente durante un período de 2 años ángulo fractuario, deformidad cifótica, índice sagital, porcentaje de compresión, grado de desplazamiento y ángulo de deformación.

Resultados:

Se incluyeron un total de 37 pacientes de 41,3 años de media, con un período de seguimiento medio de 2,2 años. El ángulo fractuario pasó de 14,8 a 17,1◦ (incremento del 15,54%), la deformidad cifótica de 15,9 a 17,7◦ (incremento del 11,32%), el índice sagital de 10,1 a 12,3 (incremento del 21,78%), el porcentaje de compresión del 32,7 al 36,8% (incremento del 12,53%), el grado de desplazamiento de 3,0 a 4,5mm (incremento del 50%) y el ángulo de deformación de 20,7 a 22,9◦ (incremento del 10,62%).

Conclusiones:

Todos los parámetros radiológicos estudiados perdieron corrección a lo largo de los 24meses de seguimiento, siendo el grado de desplazamiento y el índice sagital los más marcados. Sin embargo, la mayor parte de la pérdida de corrección ocurre en el primer año postoperatorio, estabilizándose los parámetros posteriormente hasta los 24meses de seguimiento. Recomendamos la medición de todos los parámetros previos de rutina para el seguimiento de las fracturas inestables torácicas y lumbares tratadas mediante cirugía percutánea
ABSTRACT

Objective:

To analyse the radiological outcomes in the long term of unstable thoracic and lumbar fractures treated through percutaneous surgery. Material and

methods:

Retrospective review of a series of patients with unstable thoracic and lumbar fractures treated with percutaneous minimally invasive surgery between 2010 and 2015 in three different hospital centres. Six radiological parameters were measured annually during a 2-year period Fracture angle, kyphotic deformity, sagittal index, percentage of compression, degree of displacement and deformation angle.

Results:

A total of 37 patients were included with a median age of 41.3 years and a median follow-up period of 2.2 years. Fracture angle rose from 14.8◦ to 17.1◦ (increase of 15.54%), kyphotic deformity from 15.9◦ to 17.7◦ (increase of 11.32%), sagittal index from 10.1 to 12.3 (increase of 21.78%), percentage of compression from 32.7% to 36.8% (increase of 12.53%), degree of displacement from 3.0mm to 4.4mm (increase of 50%) and deformation angle from 20.7◦ to 22.9◦ (increase of 10.62%).

Conclusions:

All the radiological parameters studied lost correction throughout the 24 months of follow-up; the degree of displacement and the sagittal index were the most marked. Nevertheless, the greatest loss of correction occurred in the first postoperative year, the parameters then stabilised over the 24 months of follow up. We routinely recommend the measurement of all previous parameters for the follow up of unstable thoracic and lumbar fractures treated through percutaneous surgery
Assuntos
Buscar no Google
Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Traumatismos Torácicos / Fraturas da Coluna Vertebral / Cifose Tipo de estudo: Estudo observacional Limite: Adulto / Feminino / Humanos / Masculino Idioma: Espanhol Revista: Neurocirugía (Soc. Luso-Esp. Neurocir.) Ano de publicação: 2018 Tipo de documento: Artigo Instituição/País de afiliação: Hospital Universitario Infanta Cristina/España / Hospital Universitario Madrid Norte Sanchinarro/España / Hospital Universitario Ramón y Cajal/España / Hospital de Vila Franca de Xira/Portugal / Instituto Universitario de Investigación en Enfermedades Músculo-Esqueléticas/España
Buscar no Google
Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Traumatismos Torácicos / Fraturas da Coluna Vertebral / Cifose Tipo de estudo: Estudo observacional Limite: Adulto / Feminino / Humanos / Masculino Idioma: Espanhol Revista: Neurocirugía (Soc. Luso-Esp. Neurocir.) Ano de publicação: 2018 Tipo de documento: Artigo Instituição/País de afiliação: Hospital Universitario Infanta Cristina/España / Hospital Universitario Madrid Norte Sanchinarro/España / Hospital Universitario Ramón y Cajal/España / Hospital de Vila Franca de Xira/Portugal / Instituto Universitario de Investigación en Enfermedades Músculo-Esqueléticas/España
...