Your browser doesn't support javascript.
loading
Recommendations of the Spanish brachytherapy group (GEB) of Spanish Society of Radiation Oncology (SEOR) and the Spanish Society of Medical Physics (SEFM) for high-dose rate (HDR) non melanoma skin cancer brachytherapy
Rodríguez, S; Arenas, M; Gutierrez, C; Richart, J; Perez-Calatayud, J; Celada, F; Santos, M; Rovirosa, A.
Afiliação
  • Rodríguez, S; Hospital Clínica Benidorm. Radiation Oncology Department. Benidorm. Spain
  • Arenas, M; Hospital Universitari Sant Joan de Reus. Radiation Oncology Department. Tarragona. Spain
  • Gutierrez, C; Institut Català d’Oncologia. Radiation Oncology Department. Hospitalet de Llobregat. Spain
  • Richart, J; Hospital Clínica Benidorm. Radiation Oncology Department. Benidorm. Spain
  • Perez-Calatayud, J; Hospital La Fe-IRIMED. Radiation Oncology Department. Valencia. Spain
  • Celada, F; Hospital La Fe-IRIMED. Radiation Oncology Department. Valencia. Spain
  • Santos, M; Hospital Clínica Benidorm. Radiation Oncology Department. Benidorm. Spain
  • Rovirosa, A; Hospital Clínic I Universitari. Radiation Oncology Department. Barcelona. Spain
Clin. transl. oncol. (Print) ; 20(4): 431-442, abr. 2018. ilus, tab, graf
Artigo em Inglês | IBECS | ID: ibc-171635
Biblioteca responsável: ES1.1
Localização: BNCS
ABSTRACT
Clinical indications of brachytherapy in non-melanoma skin cancers, description of applicators and dosimetry recommendations are described based on the literature review, clinical practice and experience of Spanish Group of Brachytherapy and Spanish Society of Medical Physics reported in the XIV Annual Consensus Meeting on Non Melanoma Skin Cancer Brachytherapy held in Benidorm, Alicante (Spain) on October 21st, 2016. All the recommendations for which consensus was achieved are highlighted in blue. Regular and small surfaces may be treated with Leipzig, Valencia, flap applicators or electronic brachytherapy (EBT). For irregular surfaces, customized molds or interstitial implants should be employed. The dose is prescribed at a maximum depth of 3-4 mm of the clinical target volume/planning target volume (CTV/PTV) in all cases except in flaps or molds in which 5 mm is appropriate. Interstitial brachytherapy should be used for CTV/PTV >5 mm. Different total doses and fraction sizes are used with very similar clinical and toxicity results. Hypofractionation is very useful twice or 3 times a week, being comfortable for patients and practical for Radiotherapy Departments. In interstitial brachytherapy 2 fractions twice a day are applied (AU)
RESUMEN
No disponible
Assuntos
Buscar no Google
Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Radiometria / Neoplasias Cutâneas / Braquiterapia Tipo de estudo: Guia de prática clínica Limite: Humanos Idioma: Inglês Revista: Clin. transl. oncol. (Print) Ano de publicação: 2018 Tipo de documento: Artigo Instituição/País de afiliação: Hospital Clínic I Universitari/Spain / Hospital Clínica Benidorm/Spain / Hospital La Fe-IRIMED/Spain / Hospital Universitari Sant Joan de Reus/Spain / Institut Català d’Oncologia/Spain
Buscar no Google
Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Radiometria / Neoplasias Cutâneas / Braquiterapia Tipo de estudo: Guia de prática clínica Limite: Humanos Idioma: Inglês Revista: Clin. transl. oncol. (Print) Ano de publicação: 2018 Tipo de documento: Artigo Instituição/País de afiliação: Hospital Clínic I Universitari/Spain / Hospital Clínica Benidorm/Spain / Hospital La Fe-IRIMED/Spain / Hospital Universitari Sant Joan de Reus/Spain / Institut Català d’Oncologia/Spain
...