Your browser doesn't support javascript.
loading
Utilidad de la tomografía computarizada de energía dual en la reducción del artefacto metálico generado por clips y coils intracraneales / The utility of dual-energy CT for metal artifact reduction from intracranial clipping and coiling
Mera Fernández, D; Santos Armentia, E; Bustos Fiore, A; Villanueva Campos, AM; Utrera Pérez, E; Souto Bayarri, M.
Afiliação
  • Mera Fernández, D; Hospital Povisa. Departamento de Radiología. Vigo. España
  • Santos Armentia, E; Hospital Povisa. Departamento de Radiología. Vigo. España
  • Bustos Fiore, A; Hospital Universitari Dexeus. Servicio de Diagnóstico por la Imagen. Barcelona. España
  • Villanueva Campos, AM; Hospital Povisa. Departamento de Radiología. Vigo. España
  • Utrera Pérez, E; Hospital Povisa. Departamento de Radiología. Vigo. España
  • Souto Bayarri, M; XXI de Santiago de Compostela. Servicio de Radiodiagnóstico. A Coruña. España
Radiología (Madr., Ed. impr.) ; 60(4): 310-317, jul.-ago. 2018. ilus, tab, graf
Article em Es | IBECS | ID: ibc-175255
Biblioteca responsável: ES1.1
Localização: BNCS
RESUMEN

Objetivo:

Evaluar la capacidad de la TC de energía dual (TCED) para reducir el artefacto metálico en pacientes con clips y coils intracraneales en estudios de angio-TC cerebral, y analizar el diferente impacto que dicha reducción tiene en función del tipo de dispositivo estudiado. Material y

métodos:

Se analizaron retrospectivamente 13 pacientes (6 clips, 7 coils). Se obtuvieron imágenes virtuales monoenergéticas (IVM) en un rango de 40 a 150 keV. Se midió el ruido dentro del área de máximo artefacto. La evaluación subjetiva del ruido fue realizada independientemente por dos radiólogos. Las diferencias encontradas se evaluaron mediante el test ANOVA. El test Mann-Whitney se utilizó para comparar las diferencias entre clips y coils. Se determinó el grado de concordancia interobservador (coeficiente κ).

Resultados:

El ruido fue más bajo en los niveles energéticos más altos (p < 0,05). El ruido fue mayor en pacientes con coils (p < 0,001). La correlación interobservador fue buena (κ = 0,72).

Conclusiones:

El uso de TCED con reconstrucciones virtuales monoenergéticas ayuda a minimizar el artefacto producido por clips y coils intracraneales en estudios de angio-TC cerebral. La reduccción del artefacto conseguida es mayor en el grupo de pacientes con clips que en el grupo de pacientes con coils
ABSTRACT

Objective:

To assess the ability of dual-energy CT (DECT) to reduce metal-related artifacts in patients with clips and coils in head CT angiography, and to analyze the differences in this reduction between both type of devices. Materials and

methods:

Thirteen patients (6 clips, 7 coils) were selected and retrospectively analized. Virtual monoenergetic images (MEI) with photon energies from 40 to 150 keV were obtained. Noise was measured at the area of maximum artifact. Subjective evaluation of streak artifact was performed by two radiologists independently. Differences between noise values in all groups were tested by using the ANOVA test. Mann-Whitney U test was used to compare the differences between clips and coils. Cohen??s κ statistic was used to determine interobserver agreement.

Results:

The lowest noise value was observed at high energy levels (p<0,05). Noise was higher in the coil group than in the clip group (p<0.001). Interobserver agreement was good (κ=0.72).

Conclusions:

TCED with MEI helps to minimize the artifact from clips ands coils in patients who undergo head CT angiography. The reduction of the artifact is greater in patients with surgical clipping than in patients with endovascular coiling
Assuntos
Buscar no Google
Coleções: 06-national / ES Base de dados: IBECS Assunto principal: Tomografia Computadorizada por Raios X / Stents / Aneurisma Intracraniano Tipo de estudo: Diagnostic_studies / Observational_studies Limite: Humans Idioma: Es Revista: Radiología (Madr., Ed. impr.) Ano de publicação: 2018 Tipo de documento: Article
Buscar no Google
Coleções: 06-national / ES Base de dados: IBECS Assunto principal: Tomografia Computadorizada por Raios X / Stents / Aneurisma Intracraniano Tipo de estudo: Diagnostic_studies / Observational_studies Limite: Humans Idioma: Es Revista: Radiología (Madr., Ed. impr.) Ano de publicação: 2018 Tipo de documento: Article
...