Estudio de validación de la versión española de la escala Fahn-Tolosa-Marín para el temblor esencial / Validation study of the Spanish version of the Fahn-Tolosa-Marín scale for essential tremor
Rev. neurol. (Ed. impr.)
; 69(7): 265-270, 1 oct., 2019. graf, tab
Artigo
em Espanhol
| IBECS
| ID: ibc-187080
Biblioteca responsável:
ES1.1
Localização: BNCS
RESUMEN
Introducción:
Hasta ahora no existe una validación formal de la versión española de la escala Fahn-Tolosa-Marín (FTM), usada ampliamente para valorar la gravedad del temblor.Objetivo:
Analizar la validez y la fiabilidad de la versión en castellano de la escala FTM. Pacientes ymétodos:
Estudio observacional transversal en pacientes diagnosticados de temblor esencial. Se evaluó la gravedad del temblor con la escala FTM; la discapacidad en el miembro superior, con la escala Disabilities of the Arm, Shoulder and Hand (DASH), y la calidad de vida relacionada con la salud, con el cuestionario Short Form-36 Health Survey (SF-36). El análisis estadístico incluyó descripción de la muestra, fiabilidad (alfa de Cronbach), validez convergente y capacidad discriminatoria (curvas ROC).Resultados:
Se incluyó a 40 pacientes (22 mujeres y 18 hombres con temblor esencial), con una edad media de 65,8 ± 14,7 años (rango 21-90 años). La fiabilidad de la FTM fue alta, con un alfa de Cronbach de 0,90 (subescala A 0,85; subescala B 0,91; subescala C 0,77). Para evaluar la discapacidad originada por el temblor esencial, la validez convergente entre las escalas DAHS y FTM (subescala C) fue adecuada, con una capacidad diagnóstica aceptable área bajo la curva de 0,86 (intervalo de confianza al 95% 0,67-1,00), sensibilidad del 78% y especificidad del 75%, para un punto de corte mayor de 5,5.Conclusión:
La escala FTM es un instrumento fiable, válido y preciso para la valoración del temblor esencial en la población española adultaABSTRACT
Introduction:
The Fahn-Tolosa-Marín (FTM) tremor rating scale has been widely used in clinics for the estimation of tremor severity. However, a Spanish language version of this scale has still not been formally validated.Aim:
To provide support to the validity and reliability of this version of FTM Scale. Patients andmethods:
A cross-sectional study was conducted on essential tremor patients. Severity was rated using the FTM scale. Upper limb disability was evaluated by terms of Disabilities of the Arm, Shoulder and Hand Scale (DASH), and to health-related quality of life using the Short Form-36 Health Survey (SF-36). Statistical analysis included sample description, reliability (Cronbachs alpha), convergent validity, and discrimination capacity tests (ROC curves).Results:
Forty patients with essential tremor (22 women, 18 men) were included, with a mean age of 65.8 ± 14.7 years (range 21-90 years). Internal consistency of the FTM was high Cronbachs alpha 0,90 (subscale A 0.85; subscale B 0.91; subscale C 0.77), and the floor and ceiling effects were negligible. The FTM (subscale C) showed high correlations with DASH, and acceptable diagnostic capacity, with an area under the curve of 0.86 (95% CI 0.67-1.00), sensitivity 78% and specificity 75% for a cut-off score > 5.5.Conclusion:
The Spanish version of FTM the rating scale is a reliable and valid tool to evaluate disability in patients with essential tremor, and a suitable instrument for use in medical research, as well as in clinical practice
Texto completo:
Disponível
Coleções:
Bases de dados nacionais
/
Espanha
Base de dados:
IBECS
Assunto principal:
Índice de Gravidade de Doença
/
Reprodutibilidade dos Testes
/
Tremor Essencial
Limite:
Adulto
/
Idoso
/
Feminino
/
Humanos
/
Masculino
Idioma:
Espanhol
Revista:
Rev. neurol. (Ed. impr.)
Ano de publicação:
2019
Tipo de documento:
Artigo
Instituição/País de afiliação:
Universidad de Valladolid/España
/
Universitario de Burgos/España