Your browser doesn't support javascript.
loading
Desarrollo y validación de una herramienta para la evaluación de la anastomosis intestinal laparoscópica en simulación / Development and Validation of a Tool for the Evaluation of Laparoscopic Intestinal Anastomosis in Simulation
Fernández, María José; Toledo, Enrique; Cañón, Marta; Manuel-Palazuelos, José Carlos; Maestre, José M.
Afiliação
  • Fernández, María José; Hospital Universitario Marqués de Valdecilla. Servicio de Cirugía General. Santander. España
  • Toledo, Enrique; Hospital Universitario Marqués de Valdecilla. Servicio de Cirugía General. Santander. España
  • Cañón, Marta; Hospital Universitario de León. León. España
  • Manuel-Palazuelos, José Carlos; Hospital Universitario de León. León. España
  • Maestre, José M; Hospital virtual Valdecilla. Santander. España
Cir. Esp. (Ed. impr.) ; 98(5): 274-280, mayo 2020. tab, ilus, graf
Artigo em Espanhol | IBECS | ID: ibc-197272
Biblioteca responsável: ES1.1
Localização: BNCS
RESUMEN

INTRODUCCIÓN:

La anastomosis intestinal laterolateral laparoscópica es una práctica habitual en la clínica y entrenada en simulación. El objetivo del estudio es el diseño y posterior validación de una herramienta fiable y reproducible para su evaluación.

MÉTODOS:

Se utilizó un método Delphi modificado para desarrollar los elementos de evaluación al que finalmente incluyeron 5 apartados (separación entre puntos, eversión, tensión, estanqueidad y iatrogenia). Se incluyeron 21 participantes, 10 residentes quirúrgicos de primer año y 11 expertos. Realizaron anastomosis enteroentéricas laterolateral laparoscópica en víscera ex-vivo porcina de 5 cm. Las evaluaciones fueron ciegas y realizadas por 2 evaluadores de forma independiente.

RESULTADOS:

Las medias obtenidas por noveles y expertos fueron respectivamente separación entre puntos 3,2 vs.5,7 (p < 0,001), eversión 3,3 vs.5,9 (p = 0,004), tensión 2,9 vs.5,9 (p = 0,001), estanqueidad 3,2 vs.5,7 (p = 0,005), iatrogenia 6,9 vs.7 (p = 0,47). El parámetro iatrogenia no es discriminatorio, por lo que fue eliminado de la herramienta. Los resultados totales fueron 12,5 los noveles y 23,2 los expertos (p = 0,001). La correlación entre observadores presenta un coeficiente de correlación intraclase de 0,99 para la separación entre puntos, 0,94 la eversión, 0,98 la tensión y 0,99 la estanqueidad. La relación entre la puntuación y la fuga anastomótica sin presión presenta una R de Rosenthal de -0,71 (p < 0,001); con presión se obtiene una R = 0,55 (p = 0,01).

CONCLUSIONES:

La herramienta diseñada es válida para discriminar entre participantes noveles y expertos, presenta muy alta concordancia entre observadores y se correlaciona con el riesgo de fuga
ABSTRACT

INTRODUCTION:

Laparoscopic side-to-side intestinal anastomosis is a common in clinic practice and training simulation. The aim of this study is to design and validate a reliable and reproducible tool for its evaluation.

METHODS:

A modified Delphi method was used to design a tool with elements that determine quality, including 5 items separation between stiches, eversion, tension, leak and iatrogenesis. The study included 21 participants (10 first-year residents and 11 experts) who performed a 5 cm laparoscopic intestinal side-to-side anastomosis with porcine viscera. The evaluations were blinded and done independently by 2 evaluators.

RESULTS:

The means obtained by novice and expert participants were, respectively separation between stiches 3.2 vs.5.7 (P < .001), eversion 3.3 vs.5.9 (P = .004), tension 2.9 vs.5.9 (P = .001), leak tightness 3.2 vs.5.7 (P = .005), iatrogenesis 6.9 vs.7 (P = .47). The iatrogenesis parameter was not discriminatory, so it was removed from the tool. The total results were 12.5 for novices and 23.2 for experts (P = .001). The correlation between observers presented an intraclass correlation coefficient of 0.99 for the separation between stiches, 0.94 for eversion, 0.98 for tension and 0.99 for leak. The correlation between the score and the leak without pressure presented a Rosenthal's R of -0.71 (P < .001); with pressure R = -0.55 (P = .01).

CONCLUSIONS:

The designed tool is valid to discriminate between novice and expert participants, presents very high concordance between observers and correlates with the risk of leak
Assuntos

Texto completo: Disponível Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Anastomose Cirúrgica / Laparoscopia / Treinamento por Simulação / Intestinos Limite: Animais / Feminino / Humanos / Masculino Idioma: Espanhol Revista: Cir. Esp. (Ed. impr.) Ano de publicação: 2020 Tipo de documento: Artigo Instituição/País de afiliação: Hospital Universitario Marqués de Valdecilla/España / Hospital Universitario de León/España / Hospital virtual Valdecilla/España

Texto completo: Disponível Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Anastomose Cirúrgica / Laparoscopia / Treinamento por Simulação / Intestinos Limite: Animais / Feminino / Humanos / Masculino Idioma: Espanhol Revista: Cir. Esp. (Ed. impr.) Ano de publicação: 2020 Tipo de documento: Artigo Instituição/País de afiliação: Hospital Universitario Marqués de Valdecilla/España / Hospital Universitario de León/España / Hospital virtual Valdecilla/España
...