Your browser doesn't support javascript.
loading
Variables asociadas a eventos adversos en neonatos con catéter venoso central de inserción periférica / Variables associated with adverse events in neonates with peripherally inserted central catheters / Variáveis associadas a eventos adversos em neonatos com cateter central de inserção periférica
Prado, Nanete Caroline da Costa; Santos, Rebecca Stefany da Costa; Almino, Romanniny Hévillyn Silva Costa; Lima, Dhyanine Morais de; Oliveira, Sylvia Silva de; Silva, Richardson Augusto Rosendo da.
Afiliação
  • Prado, Nanete Caroline da Costa; s.af
  • Santos, Rebecca Stefany da Costa; s.af
  • Almino, Romanniny Hévillyn Silva Costa; Instituto Federal de Rio Grande del Norte. Natal. Brasil
  • Lima, Dhyanine Morais de; s.af
  • Oliveira, Sylvia Silva de; s.af
  • Silva, Richardson Augusto Rosendo da; Universidad del Estado de Rio Grande del Norte. Departamento de Enfermería. Natal. Brasil
Enferm. glob ; 19(59): 36-46, jul. 2020. tab
Artigo em Espanhol | IBECS | ID: ibc-198883
Biblioteca responsável: ES1.1
Localização: BNCS
RESUMEN

OBJETIVO:

Identificar los factores asociados con la aparición de eventos adversos en el catéter de inserción central periférica en recién nacidos.

MÉTODOS:

Un estudio transversal con un enfoque cuantitativo realizado en una Unidad de Cuidados Intensivos Neonatales de un hospital de maternidad de referencia en atención materna e infantil de alto riesgo en el noreste de Brasil. Muestra de 108 neonatos recolectados de febrero a noviembre de 2016.

RESULTADOS:

La prevalencia de eventos adversos en los recién nacidos fue del 53,70%, asociada a las siguientes variables sexo masculino (p = 0,033), peso inferior a 2500 gramos (p = 0,003), inserción después de 48 horas (p = 0,027), más de tres intentos de punción (p = 0,024), dificultad de progresión del catéter (p = 0,040), presencia de intercurrencias durante la inserción del catéter (p = 0,027), sobre dos cambios de apósito = 0.009) y ubicación no central del dispositivo (p = 0.042).

CONCLUSIÓN:

Los resultados indican la necesidad de estrategias para la prevención de eventos adversos, con énfasis en la educación continua y el mejoramiento de habilidades en la gestión de este dispositivo
ABSTRACT

OBJECTIVE:

To identify the factors associated with the occurrence of adverse events by a peripherally inserted central catheter in newborns.

METHODS:

A quantitative, cross-sectional study carried out in the Neonatal Intensive Care Unit of a reference maternity hospital in high-risk maternal and child care in Northeast Brazil. The sample of 108 neonates was collected from February to November 2016.

RESULTS:

The prevalence of adverse events in newborns was 53.70%, associated with the following variables male gender (p = 0.033), weight below 2500 grams (p = 0.003), insertion performed after 48 hours of life (p = 0.027), more than three puncture attempts (p = 0.024), difficulty in inserting the catheter (p = 0.040), intercurrence during catheter insertion (p = 0.027), over two dressing changes (p = 0.009), and non-central position of the device (p = 0.042).

CONCLUSION:

The results indicate the need for strategies to prevent adverse events, with emphasis on continuing education and on the improvement of skills regarding the use of this device
RESUMO

OBJETIVO:

Identificar os fatores associados à ocorrência de eventos adversos por cateter central de inserção periférica em recém-nascidos.

MÉTODOS:

Estudo transversal, com abordagem quantitativa, realizado em Unidade de Terapia Intensiva Neonatal de uma maternidade referência no atendimento materno-infantil de alto risco no Nordeste do Brasil. Amostra de 108 neonatos coletada no período de fevereiro a novembro de 2016.

RESULTADOS:

A prevalência de eventos adversos em recém-nascidos foi de 53,70%, associados às seguintes variáveis sexo masculino (p = 0,033), peso menor que 2500 gramas (p = 0,003), inserção realizada após 48 horas de vida (p = 0,027), mais de três tentativas de punção (p = 0,024), dificuldade de progressão do cateter (p = 0,040), presença de intercorrência durante a inserção do cateter (p = 0,027), acima de duas trocas de curativos (p = 0,009) e localização não central do dispositivo (p = 0,042).

CONCLUSÃO:

Os resultados indicam a necessidade de estratégias de prevenção de eventos adversos, destacando-se a educação continuada e aprimoramento de habilidades quanto ao manejo desse dispositivo
Assuntos
Buscar no Google
Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Cateterismo Venoso Central / Terapia Intensiva Neonatal Limite: Feminino / Humanos / Masculino / Recém-Nascido Idioma: Espanhol Revista: Enferm. glob Ano de publicação: 2020 Tipo de documento: Artigo Instituição/País de afiliação: Instituto Federal de Rio Grande del Norte/Brasil / Universidad del Estado de Rio Grande del Norte/Brasil
Buscar no Google
Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Cateterismo Venoso Central / Terapia Intensiva Neonatal Limite: Feminino / Humanos / Masculino / Recém-Nascido Idioma: Espanhol Revista: Enferm. glob Ano de publicação: 2020 Tipo de documento: Artigo Instituição/País de afiliação: Instituto Federal de Rio Grande del Norte/Brasil / Universidad del Estado de Rio Grande del Norte/Brasil
...