Your browser doesn't support javascript.
loading
Taller de electrorretinografía y potenciales evocados visuales / Workshop on electroretinography and visual evoked potentials
Uclés Moreno, P.
Afiliação
  • Uclés Moreno, P; Hospital Universitario Miguel Servet. Servicio de Neurofisiología Clínica. Zaragoza. España
Rev. neurol. (Ed. impr.) ; 36(4): 391-394, 16 feb., 2003. ilus
Artigo em Es | IBECS | ID: ibc-20007
Biblioteca responsável: ES1.1
Localização: ES1.1 - BNCS
RESUMEN
Las técnicas electrofisiológicas de la visión son pruebas que registran alteraciones funcionales en fases muy precoces de la enfermedad. El flash-ERG de campo completo valora la integridad de conos, bastones y células bipolares. Se obtiene por estimulación fotópsica con Ganzfeld y electrodos corneales de lentilla o, alternativamente, de lámina de oro o de ancla. Se deben conseguir cinco repuestas la propia de los bastones, una máxima, los potenciales oscilatorios, la correspondiente a los conos y una respuesta flicker. El pattern-ERG es una respuesta de las células ganglionares. Se obtiene por estímulo morfoscópico de damero reversible, con ancho de banda entre 1 y 60 Hz. Las ondas fundamentales (0,5-5 mV) son la P50 (luminancia) y la N95 (pattern-específica). Es de gran utilidad en el diagnóstico precoz del glaucoma. Los PEV son campos eléctricos registrados en la corteza calcarina. Informan de alteraciones del nervio óptico, quiasma, radiaciones y corteza. El pattern-PEV se obtiene con un ángulo visual de 13 a 14º. La onda fundamental P100 se valora según su latencia y amplitud, y en comparación con el ojo sano. El flash-PEV sólo se utiliza en pacientes que no colaboran o que presentan una opacidad de medios (AU)
ABSTRACT
Studies of vision using electrophysiological techniques are tests which record functional alterations in very early phases of a disease. Full-field flash ERG evaluates the integrity of the cones, rods and bipolar cells. It is obtained by photopsic stimulation with Ganzfeld and contact lens corneal electrodes or, alternatively, gold leaf or anchor electrodes. Five responses must be obtained that of the rods, a maximum, oscillatory potentials, that of the cones and a flicker response. PatternERG is a response of the ganglionic cells, which is obtained by pattern reversal morphoscopic stimulation, with a bandwidth between 1 and 60 Hz. The fundamental waves (0.5-5 mV) are P50 (luminance) and N95 (pattern-specific). This is of great value in the early diagnosis of glaucoma. VEP are electrical fields that are recorded in the calcarine cortex. They give information about alterations in the optic nerve, chiasm, radiations and cortex. Pattern-VEP is obtained with a visual angle of between 13 and 14º. The fundamental wave P100 is evaluated according to its latency and amplitude, and by comparing it with a healthy eye. Flash-VEP is only used on patients who do not collaborate or who present an opacity of media (AU)
Assuntos
Buscar no Google
Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Doença de Parkinson Tipo de estudo: Estudo de rastreamento Aspecto: Preferência do paciente Limite: Adulto / Criança / Humanos / Masculino Idioma: Espanhol Revista: Rev. neurol. (Ed. impr.) Ano de publicação: 2003 Tipo de documento: Artigo Instituição/País de afiliação: Hospital Universitario Miguel Servet/España
Buscar no Google
Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Doença de Parkinson Tipo de estudo: Estudo de rastreamento Aspecto: Preferência do paciente Limite: Adulto / Criança / Humanos / Masculino Idioma: Espanhol Revista: Rev. neurol. (Ed. impr.) Ano de publicação: 2003 Tipo de documento: Artigo Instituição/País de afiliação: Hospital Universitario Miguel Servet/España
...