Your browser doesn't support javascript.
loading
Tonometría de rebote con puntas nuevas y reesterilizadas versus tonometría de aplanación Goldmann en niños / Rebound tonometry with re-sterilised tips versus Goldmann applanation tonometry in children
Aceituno Paredes, SC; Asturias de León, AL; Barnoya Pérez, J.
Afiliação
  • Aceituno Paredes, SC; Unidad Nacional de Oftalmología de Guatemala. Ciudad de Guatemala. Guatemala
  • Asturias de León, AL; Unidad Nacional de Oftalmología de Guatemala. Ciudad de Guatemala. Guatemala
  • Barnoya Pérez, J; Unidad Nacional de Oftalmología de Guatemala. Ciudad de Guatemala. Guatemala
Arch. Soc. Esp. Oftalmol ; 95(7): 322-326, jul. 2020. ilus, tab
Artigo em Espanhol | IBECS | ID: ibc-201475
Biblioteca responsável: ES1.1
Localização: BNCS
RESUMEN
ANTECEDENTES El tonómetro de Goldmann (TAG) es el estándar de oro para la medición de la presión intraocular (PIO). En pacientes pediátricos esta medición resulta desafiante. El tonómetro de rebote (TRB) es un instrumento fácil de utilizar. En la Unidad Nacional de Oftalmología (UNO) se reesterilizan las puntas del TRB (TRB RE).

OBJETIVO:

Evaluar la correlación entre el TRB con puntas nuevas y reesterilazadas en comparación con el TAG. MATERIALES Y

MÉTODOS:

Estudio transversal con 25 pacientes sanos entre 8 y 12 años de edad elegidos al azar, que asistieron a la consulta externa de la UNO durante el 2019. Se les tomó la PIO con el TRB usando puntas reesterilizadas, luego con una punta nueva y, por último, con el TAG.

RESULTADOS:

Existe correlación entre la PIO tomada con el TAG y la PIO tomada con el TRB (p = 0,0011). No se encontró correlación entre el TAG y el TRB RE, ni el TRB con el TRB RE.

CONCLUSIONES:

El TRB puede ser utilizado en pacientes pediátricos teniendo en cuenta que habitualmente se sobreestima la PIO con respecto al TAG
ABSTRACT

BACKGROUND:

The Goldmann applanation tonometer (TAG) is the gold standard for the measurement of intraocular pressure (IOP). In paediatric patients this measurement is challenging. The rebound tonometer (TRB) is an easy to use instrument. In the National Ophthalmology Unit (UNO) the tips of the TRB are re-sterilised (TRB RE).

OBJECTIVE:

To evaluate the correlation between TRB with new and re-sterilised tips compared to TAG. Materials And

METHODS:

A cross-sectional study was conducted on 25 healthy patients between 8 and 12 years of age, chosen at random, and seen in the UNO outpatients department during 2019. IOPs were measured with TRB using re-sterilized tips and then with a new tip, and finally with TAG.

RESULTS:

There was a correlation between IOP measured with TAG and IOP measured with TRB (P=.0011). No correlation was found between TAG and TRB RE, or TRB with TRB RE.

CONCLUSIONS:

The TRB can be used in paediatric patients, taking into account that IOP usually overestimates with respect to TAG
Assuntos
Buscar no Google
Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Tonometria Ocular / Glaucoma / Pressão Intraocular / Manometria Limite: Criança / Feminino / Humanos / Masculino Idioma: Espanhol Revista: Arch. Soc. Esp. Oftalmol Ano de publicação: 2020 Tipo de documento: Artigo Instituição/País de afiliação: Unidad Nacional de Oftalmología de Guatemala/Guatemala
Buscar no Google
Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Tonometria Ocular / Glaucoma / Pressão Intraocular / Manometria Limite: Criança / Feminino / Humanos / Masculino Idioma: Espanhol Revista: Arch. Soc. Esp. Oftalmol Ano de publicação: 2020 Tipo de documento: Artigo Instituição/País de afiliação: Unidad Nacional de Oftalmología de Guatemala/Guatemala
...