Your browser doesn't support javascript.
loading
Effects of wearing swimming goggles on non-invasive tear break-up time in a laboratory setting
Vera, Jesús; Redondo, Beatríz; Molina, Rubén; Jiménez, Raimundo.
Afiliação
  • Vera, Jesús; University of Granada. Faculty of Sciences. Department of Optics. Spain
  • Redondo, Beatríz; University of Granada. Faculty of Sciences. Department of Optics. Spain
  • Molina, Rubén; University of Granada. Faculty of Sciences. Department of Optics. Spain
  • Jiménez, Raimundo; University of Granada. Faculty of Sciences. Department of Optics. Spain
J. optom. (Internet) ; 15(2): 1-6, April-June 2022.
Artigo em Inglês | IBECS | ID: ibc-204570
Biblioteca responsável: ES1.1
Localização: ES15.1 - BNCS
ABSTRACT

Purpose:

The use of swimming goggles (SG) has demonstrated to alter different ocular parameters, however, the impact of wearing SG on the tear film stability remain unknown. The main objective of this study was to determine the short-term effects of wearing SG on tear film surface quality break-up time (TFSQ-BUT).

Methods:

Twenty-eight young healthy adults (14 men and 14 women) wore a drilled SG, and TFSQ-BUT was measured before, during and after SG use. Dynamic-area high-speed videokeratoscopy was used for the non-invasive assessment of TFSQ-BUT.

Results:

TFSQ-BUT was significantly reduced while SG wear in comparison to the baseline measurement (4.8 ± 4.5 s vs. 8.8 ± 6.9 s; corrected p-value = 0.017, d = 0.57, mean difference = 4.0 [0.6, 7.3]; 45% reduction). Immediately after SG removal, TFSQ-BUT rapidly recovered baseline levels (8.2 ± 5.9 s vs. 8.8 ± 6.9 s; corrected p-value = 0.744). The impact of wearing SG on TFSQ-BUT were independent of the gender of the participants (p = 0.934).

Conclusion:

The use of SG induces a TFSQ-BUT reduction, with these changes returning to baseline levels immediately after SG removal. These data may be of relevance for the management of dry eye patients, who need to avoid circumstances that exacerbate tear film instability. Nevertheless, these results must be interpreted with caution since the experiment did not entirely mimic real-life conditions (e.g., eye cup piece drilled, time of exposure, environmental conditions). Future studies should consider the inclusion of dry eye patients and older individual in order to explore the generalizability of these findings. (AU)
Assuntos


Texto completo: Disponível Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Síndromes do Olho Seco / Xeroftalmia / Dispositivos de Proteção dos Olhos Limite: Adulto / Feminino / Humanos / Masculino Idioma: Inglês Revista: J. optom. (Internet) Ano de publicação: 2022 Tipo de documento: Artigo Instituição/País de afiliação: University of Granada/Spain

Texto completo: Disponível Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Síndromes do Olho Seco / Xeroftalmia / Dispositivos de Proteção dos Olhos Limite: Adulto / Feminino / Humanos / Masculino Idioma: Inglês Revista: J. optom. (Internet) Ano de publicação: 2022 Tipo de documento: Artigo Instituição/País de afiliação: University of Granada/Spain
...