Your browser doesn't support javascript.
loading
Comparación de la corrección del offset femoral tras el empleo de un vástago monobloque y un vástago con cuello modular en la artroplastia total de cadera primaria / Comparison of the correction of the femoral offset after the use of a stem with modular neck and its monoblock homologue in total primary hip arthroplasty
López, R. E; Gómez Aparicio, S; Pelayo de Tomás, J. M; Morales Suárez Varela, M; Rodrigo Pérez, J. L.
Afiliação
  • López, R. E; Hospital Universitario Doctor Peset. Valencia. España
  • Gómez Aparicio, S; Hospital Universitario Doctor Peset. Valencia. España
  • Pelayo de Tomás, J. M; Hospital Universitario Doctor Peset. Valencia. España
  • Morales Suárez Varela, M; Universidad de Valencia. Facultad de Farmacia. Valencia. España
  • Rodrigo Pérez, J. L; Hospital Universitario Doctor Peset. Valencia. España
Rev. esp. cir. ortop. traumatol. (Ed. impr.) ; 66(2): 77-85, Mar-Abr 2022. ilus, tab, graf
Artigo em Espanhol | IBECS | ID: ibc-204941
Biblioteca responsável: ES1.1
Localização: ES15.1 - BNCS
RESUMEN
Introducción y

objetivos:

Los vástagos con doble modularidad fueron introducidos con la ventaja teórica de restaurar de forma más precisa la anatomía de la cadera a través del ajuste del offset femoral y la longitud de miembros. Los cuellos intercambiables permiten cambios intraoperatorios de angulación, anteversión y longitud. Nuestro objetivo es estudiar si se consigue una mejor corrección del offset femoral con la prótesis H MAX-M® (Limacorporate, San Daniele, Italia) frente a su homólogo monobloque. Material y

métodos:

Se realizó un estudio de cohortes prospectivo mediante muestreo consecutivo sobre pacientes intervenidos de artroplastia total de cadera con el diagnóstico de coxartrosis desde enero de 2011 hasta diciembre 2015. Esta cohorte posee 2 brazos, un brazo incluyó a los pacientes intervenidos mediante vástago con cuello modular y el otro a los pacientes intervenidos mediante vástago monobloque. Se realizó la medición radiográfica del offset de la cadera intervenida, la cadera contralateral y se calculó la diferencia entre ambos valores. Las medias de las mediciones obtenidas para cada brazo de la cohorte se compararon entre sí.

Resultados:

No se han observado diferencias estadísticamente significativas en la corrección del offset femoral entre el grupo modular y monobloque, determinado como la diferencia de offset entre la cadera operada y la cadera contralateral (p=0,323). Tampoco se observaron diferencias en los valores de offset postoperatorio (p=0,097). Cabe decir que tanto para la prótesis modular como para la prótesis monobloque el grupo mayoritario es aquel con offset restaurado (p=0,001).(AU)
ABSTRACT
Introduction and

objective:

Dual modularity stems were introduced with the theoretical advantage of restoring hip anatomy more precisely through femoral offset and limb length adjustment. Interchangeable necks allow for intraoperative angulation, anteversion and length changes. Our objective is to study whether a better femoral offset correction is achieved with the H MAX-M® prosthesis (Limacorporate, San Daniele, Italy) compared to its monoblock counterpart. Material and

methods:

A prospective cohort study was conducted by means of consecutive sampling on adult patients undergoing total hip arthroplasty with the diagnosis of coxarthrosis between January 2011 and December 2015. This cohort has two arms, one arm included patients who underwent modular neck arthroplasty and the other included patients who underwent monoblock total hip arthroplasty. Radiographic offset measurement of the operated hip and the contralateral hip was performed, and the difference between both values was calculated. The mean of the measurements obtained for each arm of the cohort were compared with each other.

Results:

No statistically significant differences were observed in the difference in offset between the operated hip and the contralateral hip (P=.323). No statistically significant differences were observed in the correction of the femoral offset, determined as the difference between the operated hip and the contralateral hip (P=.323). Nor were differences observed in the postoperative offset values (P=.097). It should be noted that for both designs, the majority group is the one with restored offset (P=.001).(AU)
Assuntos


Texto completo: Disponível Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Osteoartrite do Quadril / Artroplastia de Quadril / Quadril / Articulação do Quadril / Prótese de Quadril Limite: Feminino / Humanos / Masculino Idioma: Espanhol Revista: Rev. esp. cir. ortop. traumatol. (Ed. impr.) Ano de publicação: 2022 Tipo de documento: Artigo Instituição/País de afiliação: Hospital Universitario Doctor Peset/España / Universidad de Valencia/España

Texto completo: Disponível Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Osteoartrite do Quadril / Artroplastia de Quadril / Quadril / Articulação do Quadril / Prótese de Quadril Limite: Feminino / Humanos / Masculino Idioma: Espanhol Revista: Rev. esp. cir. ortop. traumatol. (Ed. impr.) Ano de publicação: 2022 Tipo de documento: Artigo Instituição/País de afiliação: Hospital Universitario Doctor Peset/España / Universidad de Valencia/España
...