Your browser doesn't support javascript.
loading
Concordancia interobservador del electroencefalograma integrado por amplitud en el neonato con asfixia perinatal / Inter-observer reliability for amplitude-integrated EEG in the newborn with perinatal asphyxia
Bustamante-Hervás, Carmen; Valverde, Eva; Vega-Del-Val, Cristina; Schuffelmann, Susana; Arnaez, Juan.
Afiliação
  • Bustamante-Hervás, Carmen; Complejo Asistencial Universitario de Burgos. Unidad de Neonatología. Burgos. España
  • Valverde, Eva; Hospital Universitario Infantil La Paz. Fundación NeNe. Madrid. España
  • Vega-Del-Val, Cristina; Complejo Asistencial Universitario de Burgos. Unidad de Neonatología. Burgos. España
  • Schuffelmann, Susana; Complejo Asistencial Universitario de Burgos. Unidad de Neonatología. Burgos. España
  • Arnaez, Juan; Complejo Asistencial Universitario de Burgos. Fundación NeNe. Burgos. España
An. pediatr. (2003. Ed. impr.) ; 96(5): 416-421, mayo 2022. ilus, tab
Artigo em Espanhol | IBECS | ID: ibc-206053
Biblioteca responsável: ES1.1
Localização: ES15.1 - BNCS
RESUMEN

Introducción:

La electroencefalografía integrada por amplitud (aEEG) es una herramienta utilizada en la neuromonitorización del neonato crítico. En el paciente con asfixia perinatal, su interpretación es clave para identificar a los candidatos a hipotermia terapéutica, detectar crisis subclínicas y aportar información pronóstica. Nuestro objetivo fue analizar la concordancia en la interpretación del aEEG entre neonatólogos con distinto nivel de experiencia. Material y

métodos:

Estudio retrospectivo unicéntrico de los recién nacidos ≥ 35 semanas con asfixia perinatal incluidos consecutivamente durante un periodo de dos años y monitorizados con aEEG durante al menos 6 horas. El médico de guardia interpretó el aEEG respecto al trazado de base, los ciclos vigilia-sueño y las crisis. Los aEEG fueron revisados de forma ciega por dos neonatólogas con distinta experiencia. Se analizó la concordancia (coeficiente Kappa de Cohen, k) de los aEEG divididos en periodos de 0-3 horas y 3-6 horas de vida, entre ambas y la de su consenso con el médico de guardia.

Resultados:

Se incluyeron 75 neonatos, 5 de ellos no se monitorizaron. Se analizaron 132 trazados con una concordancia muy buena entre las dos examinadoras en las tres características del aEEG. El k respecto al médico de guardia fue muy bueno para el trazado de base (k=0,93), moderado (k=0,52) para los ciclos vigilia-sueño y débil (k=0,32) para las crisis.

Conclusiones:

Este estudio apoya una mayor facilidad para interpretar adecuadamente el trazado de base frente a los ciclos vigilia-sueño o las crisis, mejorando cuando se recibe una formación dirigida en el aEEG. (AU)
ABSTRACT

Introduction:

Amplitude integrated electroencephalography (aEEG) is a widely tool used for neuromonitoring in the critical neonate. In the patient with perinatal asphyxia, its interpretation is key to identifying candidates for therapeutic hypothermia, detecting subclinical seizures and providing pronostic information. Our aim was to analyze the concordance in the interpretation of aEEG among neonatologists with different level of experience. Material and

methods:

Unicenter retrospective study of newborns ≥35 weeks with perinatal asphyxia included consecutively over a two-year period and monitored with aEEG for at least 6h. The bedside neonatologist interpreted aEEG regarding background pattern, sleep-wake cycling, and seizures. The aEEG tracings were blindly reviewed by two neonatologists with different experience. The aEEG tracings were divided into periods of 0–3h and 3-6h of life, and the concordance (Cohen Kappa coefficient, k), between the two examiners and that of their consensus with the bedside neonatologist, was analyzed.

Results:

Seventy-five newborns were included, 5 of them were not aEEG-monitored. 132 tracings were analyzed with a very good concordance between the two examiners in the three characteristics of the aEEG. The k for the bedside neonatologist was very good for background pattern (k=0.93), moderate (k=0.52) for sleep-wake cycling, and weak (k=0.32) for seizures.

Conclusions:

This study supports that background pattern is easily interpreted compared to sleep-wake cycling or crisis, improving when targeted training on aEEG is received. (AU)
Assuntos


Texto completo: Disponível Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Asfixia / Eletroencefalografia / Hipotermia Limite: Humanos / Recém-Nascido Idioma: Espanhol Revista: An. pediatr. (2003. Ed. impr.) Ano de publicação: 2022 Tipo de documento: Artigo Instituição/País de afiliação: Hospital Universitario Infantil La Paz/España / Complejo Asistencial Universitario de Burgos/España

Texto completo: Disponível Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Asfixia / Eletroencefalografia / Hipotermia Limite: Humanos / Recém-Nascido Idioma: Espanhol Revista: An. pediatr. (2003. Ed. impr.) Ano de publicação: 2022 Tipo de documento: Artigo Instituição/País de afiliação: Hospital Universitario Infantil La Paz/España / Complejo Asistencial Universitario de Burgos/España
...