Your browser doesn't support javascript.
loading
Comparison, within-session repeatability and normative data of three phoria tests
Facchin, Alessio; Maffioletti, Silvio.
Afiliação
  • Facchin, Alessio; IRSOO – Institute of Research and Studies in Optics and Optometry. University of Milano-Bicocca. Italy
  • Maffioletti, Silvio; IRSOO – Institute of Research and Studies in Optics and Optometry. University of Turin. Italy
J. optom. (Internet) ; 14(3): 263-274, July - September 2021. tab, graf
Artigo em Inglês | IBECS | ID: ibc-209004
Biblioteca responsável: ES1.1
Localização: ES15.1 - BNCS
ABSTRACT

Purpose:

Phoria measurements form a routine part of the examination of binocular vision. Various studies have compared different methods of phoria measurement and their repeatability between sessions. However, no studies have accounted for within-session repeatability, and few norms have been available to date. Our aims were to assess the short-term within-session repeatability, the agreement and the comparisons between three phoria tests and the delineation of normative data.

Method:

The participants comprised 315 refractive corrected participants with a normal binocular vision, with ages between 20 and 80 years. Phoria was measured using three

methods:

von Graefe (VG), modified Thorington (MT) and Thorighton (TH) procedures. Each measurement was taken 3 consecutive times at far and near.

Results:

The repeatability between measurements was high (0.87 to 0.96), but the relationship between tests was medium (0.407 to 0.682). About the mean bias, VG show more exo values (0.02 to 0.14 at far and 0.07 to 0.14 at near) and MT and TH similar values (−0.04 to 0.08 at far and −0.1 to 0.03 at near). The best agreement between tests was for TH and MT (LoA = 2.33 at far and LoA = 4.44 at near). Normative data for non-presbyopic were provided.

Conclusion:

Overall, there is a high agreement between MT and TH. Conversely, VG shows more exo values at near and shows large limits of agreement. We recommend that subjective measurements of phoria can best be quantified once using the MT or TH techniques in free space and the values compared with updated norms. (AU)
Assuntos


Texto completo: Disponível Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Testes Visuais / Visão Binocular / Estrabismo Limite: Adulto / Idoso Idioma: Inglês Revista: J. optom. (Internet) Ano de publicação: 2021 Tipo de documento: Artigo Instituição/País de afiliação: IRSOO – Institute of Research and Studies in Optics and Optometry/Italy

Texto completo: Disponível Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Testes Visuais / Visão Binocular / Estrabismo Limite: Adulto / Idoso Idioma: Inglês Revista: J. optom. (Internet) Ano de publicação: 2021 Tipo de documento: Artigo Instituição/País de afiliação: IRSOO – Institute of Research and Studies in Optics and Optometry/Italy
...