Your browser doesn't support javascript.
loading
Telemedicina en retinopatía del prematuro: Atravesando fronteras en la salud visual pediátrica. Estudio TELEROP / Telemedicine in retinopathy of prematurity: Crossing borders in pediatric vision health. TELEROP study
Sosa Lockward, J. A; Abreu Arbaje, N; García Méndez, M; Juan, A; Sosa Peña, J. A; Batlle Pichardo, J. F.
Afiliação
  • Sosa Lockward, J. A; Hospital Dr. Elías Santana. Servicio de Oftalmología. Santo Domingo. República Dominicana
  • Abreu Arbaje, N; Hospital Dr. Elías Santana. Departamento de Retina y Vítreo. Santo Domingo. República Dominicana
  • García Méndez, M; Hospital Dr. Elías Santana. Departamento de Retina y Vítreo. Santo Domingo. República Dominicana
  • Juan, A; Hospital Dr. Elías Santana. Departamento de Retina y Vítreo. Santo Domingo. República Dominicana
  • Sosa Peña, J. A; Hospital Dr. Elías Santana. Servicio de Oftalmología Pediátrica y Estrabismo. Santo Domingo. República Dominicana
  • Batlle Pichardo, J. F; Hospital Dr. Elías Santan. Servicio de Retina y Vítreo y Servicio de Oftalmología. Santo Domingo. República Dominicana
Arch. Soc. Esp. Oftalmol ; 97(10): 543-548, Oct. 2022.
Artigo em Espanhol | IBECS | ID: ibc-209648
Biblioteca responsável: ES1.1
Localização: ES15.1 - BNCS
RESUMEN
Objetivo general Evaluar la precisión y validez de imágenes vía teléfono inteligente en comparación con el sistema RetCam® para el diagnóstico de retinopatía del prematuro (ROP). Metodología Estudio observacional, de corte longitudinal y enmascarado realizado en el hospital Dr. Elías Santana. Se incluyeron infantes con peso al nacer ≤ 1.500 g, edad gestacional ≤ 30 semanas y/o pacientes expuestos a factores de riesgo o complicaciones ligadas a ROP. Estos sujetos fueron tamizados empleando imágenes vía teléfono inteligente o RetCam®, ambos comparados con la fondoscopía convencional. Se utilizó la clasificación de ICROP para la estadificación. Los resultados principales analizados fueron sensibilidad, especificidad, valores predictivos e índice kappa. Resultados Se obtuvieron 915 imágenes (n = 121), distribuidas en grupo teléfono inteligente (50,4%) y grupo RetCam® (49,6%) entre agosto del 2020 y marzo del 2021. Los sujetos que presentaron ROP tuvieron menor edad gestacional (30,2 sem ± 2.8), peso al nacer (1.361 g ± 398) y mayor exposición a oxigenoterapia (12,8 días ± 11,3). El grupo RetCam® presentó sensibilidad = 80%, especificidad = 78%, valor predictivo positivo = 90% e índice kappa = 0,70. El grupo teléfono inteligente presentó sensibilidad = 88%, especificidad = 90%, valor predictivo positivo = 93,75% e índice kappa = 0,81. Conclusiones Ambos métodos diagnósticos fueron precisos para identificar ROP. El grupo teléfono inteligente obtuvo resultados superiores con una excelente resolución, representando un método costo-efectivo para crear un impacto global en la reducción de la ceguera prevenible en población pediátrica (AU)
ABSTRACT
General objective To evaluate the accuracy and validity of images with smartphone compared to the RetCam® system for the diagnosis of retinopathy of prematurity (ROP). Methodology Observational, longitudinal and masked study carried out at the Dr. Elías Santana hospital. Infants with birth weight ≤ 1500 g, gestational age ≤ 30 weeks and/or patients exposed to risk factors or complications linked to ROP were included. These subjects were screened using images with smartphone or RetCam®, both compared to conventional fundoscopy. The ICROP classification was used for staging. The main results analyzed were sensitivity, specificity, positive predictive values and kappa index. Results 915 images (n = 121) were obtained, distributed in smartphone group (50.4%) and RetCam® group (49.6%) between August 2020 and March 2021. Subjects with ROP had lower gestational age (30.2 sem ± 2.8), birth weight (1361 g ± 398), and greater exposure to oxygen therapy (12.8 days ± 11.3). The RetCam® group presented sensitivity = 80%, specificity = 78%, positive predictive value = 90% and kappa index = 0.70. The smartphone group presented sensitivity = 88%, specificity = 90%, positive predictive value = 93.75% and kappa index = 0.81. Conclusions Both diagnostic methods were accurate to identify ROP. The smartphone group obtained superior results with excellent resolution, representing a cost-effective method to create a global impact on reducing preventable blindness in the pediatric population (AU)
Assuntos

Buscar no Google
Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Retinopatia da Prematuridade / Recém-Nascido Prematuro / Telemedicina Limite: Humanos / Recém-Nascido Idioma: Espanhol Revista: Arch. Soc. Esp. Oftalmol Ano de publicação: 2022 Tipo de documento: Artigo Instituição/País de afiliação: Hospital Dr. Elías Santan/República Dominicana / Hospital Dr. Elías Santana/República Dominicana
Buscar no Google
Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Retinopatia da Prematuridade / Recém-Nascido Prematuro / Telemedicina Limite: Humanos / Recém-Nascido Idioma: Espanhol Revista: Arch. Soc. Esp. Oftalmol Ano de publicação: 2022 Tipo de documento: Artigo Instituição/País de afiliação: Hospital Dr. Elías Santan/República Dominicana / Hospital Dr. Elías Santana/República Dominicana
...