Your browser doesn't support javascript.
loading
Valoración de la seguridad del paciente en la práctica clínica de terapia renal sustitutiva en las unidades de vigilancia intensiva / Patient safety assessment in the clinical practice of renal replacement therapy in intensive care unit
Suárez, María del Tránsito; Rodas, Lida; Quíntela, Marta; Mejía, Adriana Patricia.
Afiliação
  • Suárez, María del Tránsito; Hospital Clinic. Servicio de nefrología y trasplante renal. Barcelona. España
  • Rodas, Lida; Hospital Clinic. Servicio de nefrología y trasplante renal. Barcelona. España
  • Quíntela, Marta; Hospital Clinic. Servicio de nefrología y trasplante renal. Barcelona. España
  • Mejía, Adriana Patricia; Hospital Clinic. Servicio de nefrología y trasplante renal. Barcelona. España
Enferm. nefrol ; 26(1): 49-58, Mar 30, 2023. tab, graf
Artigo em Espanhol | IBECS | ID: ibc-218439
Biblioteca responsável: ES1.1
Localização: ES15.1 - BNCS
RESUMEN

Introducción:

La seguridad del paciente en unidades de vigilancia intensiva, con terapia renal sustitutiva intermitente, está influenciada por diversos factores los inherentes al paciente, humanos y técnicos.

Objetivo:

Identificar los factores de riesgo y principales incidencias presentes en la práctica clínica, que interfieren en la seguridad del paciente al que se le realiza terapia sustantiva renal intermitente.Material y

Método:

Estudio descriptivo y retrospectivo de 413 sesiones de terapia sustitutiva renal intermitente. Se obtuvieron datos demográficos, clínicos, complicaciones clínicas, técnicas, controles de monitores, medidas correctivas y factores de riesgo relacionados con las enfermeras mediante un cuestionario de experteza en diálisis.

Resultados:

413 sesiones; (52,1%) hemodiálisis intermitente. Edad media 65 años; 78,7% sexo masculino; motivo de ingreso shock séptico (35,1%).Incidencias error en la asignación de la modalidad (33,2%), pautas sin actualizar (30,5%), disfunción del acceso vascular (15,7%). Complicaciones clínicas 47,6 en hemodiálisis intermitente, destacando hipotensión en 41,2%.Complicaciones técnicas en el 37,7% de las sesiones, coagulación total o parcial del circuito extracorpóreo (16,7%). Relacionados con el personal falta de un programa estandarizado de formación (57,1%), variabilidad de personal (81%) y no asistencia a la capacitación programada (52,4%).

Conclusión:

La seguridad del paciente con terapia sustitución renal en unidades de vigilancia intensiva, es un proceso multifactorial relacionados con aspectos no modificables (asociados al paciente), incidencias durante el procedimiento y complicaciones. Aunque no se produjeron efectos adversos mayores en la evolución clínica del paciente, éstos son considerados potenciales y algunos previsibles, controlables y evitables.(AU)
ABSTRACT

Introduction:

Patient safety in intensive care units with intermittent renal replacement therapy is influenced by different factors; including patient-related, human, and technical factors.

Objective:

Identify risk factors and major incidences present in clinical practice affecting the patient safety on intermittent renal replacement therapy.Material and

Method:

Descriptive and retrospective study of 413 sessions of intermittent renal replacement therapy. Demographic and clinical data, clinical and technical complications, monitor controls, corrective measures, and nurse-related risk factors were obtained using a dialysis expert questionnaire.

Results:

Out of the 413 sessions, 52.1% were intermittent hemodialysis. Patients had a mean age of 65 years and 78.7% were male. 35.1% were admitted by septic shock. Incidences include error in modality assignment (33.2%), outdated protocols (30.5%) and vascular access dysfunction (15.7%). As clinical complications found 47.6% in intermittent hemodialysis and 41.2% had hypotension. Technical complications in 37.7% of sessions, with total or partial extracorporeal circuit coagulation (16.7%). As personnel related factors highlighted the lack of standardized training program (57.1%), personnel variability (81%), and not attending scheduled training (52.4%).

Conclusions:

Patient safety with renal replacement therapy in intensive care units is a multifactorial process involving non-modifiable patient-related aspects, incidences during the procedure, and complications. Although no major adverse effects were produced in the patient’s clinical evolution, risk factors are considered potential and some of them predictable, controllable, and avoidable.(AU)
Assuntos


Texto completo: Disponível Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Incidência / Fatores de Risco / Diálise Renal / Segurança do Paciente / Unidades de Terapia Intensiva Limite: Humanos Idioma: Espanhol Revista: Enferm. nefrol Ano de publicação: 2023 Tipo de documento: Artigo Instituição/País de afiliação: Hospital Clinic/España

Texto completo: Disponível Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Incidência / Fatores de Risco / Diálise Renal / Segurança do Paciente / Unidades de Terapia Intensiva Limite: Humanos Idioma: Espanhol Revista: Enferm. nefrol Ano de publicação: 2023 Tipo de documento: Artigo Instituição/País de afiliação: Hospital Clinic/España
...