Your browser doesn't support javascript.
loading
Detección y cuantificación de VHB y VHC en muestras de plasma mediante la utilización de diferentes ensayos moleculares: estudio comparativo / Detection and quantification of HBV and HCV in plasma samples by means of different molecular assays: Comparative study
Manso, Tamara; Salazar, Adolfo de; Rodríguez-Velasco, María; García, Federico; Aguilera, Antonio.
Afiliação
  • Manso, Tamara; Hospital Público da Mariña. Burela. España
  • Salazar, Adolfo de; Hospital Universitario Clinico San Cecilio. Instituto de Investigacion Ibs.Granada. Granada. España
  • Rodríguez-Velasco, María; Hospital El Bierzo. Ponferrada. España
  • García, Federico; Hospital Universitario Clinico San Cecilio. Instituto de Investigacion Ibs.Granada. Granada. España
  • Aguilera, Antonio; Complejo Hospitalario Universitario de Santiago de Compostela. Santiago de Compostela. España
Enferm. infecc. microbiol. clín. (Ed. impr.) ; 42(1): 13-16, Ene. 2024. tab, graf
Artigo em Espanhol | IBECS | ID: ibc-229213
Biblioteca responsável: ES1.1
Localização: ES15.1 - BNCS
RESUMEN

Introducción:

La carga viral es un marcador muy útil para realizar el seguimiento de los pacientes infectados por VHB y VHC. Este trabajo compara ensayos basados en amplificación mediada por transcripción y en PCR a tiempo real con el objetivo de comprobar si pueden ser intercambiables. Material y

métodos:

Estudio bicéntrico en el que se analizó la carga viral de 147 muestras de plasma de pacientes infectados por VHB y 229 por VHC, mediante ensayos basados en amplificación mediada por transcripción (Aptima® HBV Quant y Aptima® HCV Quant Dx, que utilizan el sistema Panther (Hologic®)) y PCR a tiempo real (COBAS® AmpliPrep / COBAS® TaqMan® y COBAS® 6800), calculando el grado de concordancia entre ellos.

Resultados:

Se detectó carga viral en ambos equipos en 60 (40,82%) muestras de VHB (mediana del log de la carga viral COBAS® 2,51UI/mL (RIC 2,20-3,17), Panther 2,71UI/mL (RIC 2,21-3,22)) y en 39 (16,96%) muestras de VHC (mediana del log de la carga viral COBAS® 3,93UI/mL (RIC 2,24-6,01), Panther 3,80UI/mL (RIC 1,99-6,14)). La concordancia entre ambos equipos fue de κ=0,943 para VHB y κ=0,925 para VHC. La comparación de las muestras con carga viral detectada mediante los 2 ensayos mostró una correlación alta tanto para VHB (R2=0,86) como para VHC (R2=0,97).

Conclusiones:

Los ensayos basados tanto en amplificación mediada por transcripción como en PCR a tiempo real pueden ser intercambiables para el manejo de pacientes infectados con VHB y VHC.(AU)
ABSTRACT

Introduction:

Viral load is a very useful marker for monitoring patients infected with HBV and HCV. This work compares assays based on transcription-mediated amplification and on real-time PCR to verify whether they can be interchangeable. Material and

methods:

a bicentric study, in which 147 plasma samples from patients infected with HBV and 229 with HCV were analyzed, was carried out. Transcription-mediated amplification-based assays (Aptima® HBV Quant and Aptima® HCV Quant Dx, employing Panther system (Hologic®)) and on real-time PCR (COBAS® AmpliPrep / COBAS® TaqMan® and COBAS® 6800) were used and the degree of concordance between them was calculated.

Results:

Viral load was detected in both systems in 60 (40.82%) HBV samples (median log viral load COBAS® 2.51IU/mL (IQR 2.20-3.17), Panther 2.71IU/mL (IQR 2.21-3.22)) and in 39 (16.96%) HCV samples (median log viral load COBAS® 3.93IU/mL (IQR 2.24-6.01), Panther 3.80IU/mL (IQR 1.99-6.14)). The agreement between both systems was κ=0.943 for HBV and κ=0.925 for HCV. Comparison of viral load samples detected by both assays showed a hight correlation for HBV (R2=0.86) and for HCV (R2=0.97).

Conclusions:

Both transcription-mediated amplification and on real-time PCR based assays may be interchangeable for the management of patients infected with HBV and HCV.(AU)
Assuntos

Buscar no Google
Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Plasma / Vírus da Hepatite B / Hepacivirus / Carga Viral / Reação em Cadeia da Polimerase em Tempo Real Limite: Feminino / Humanos / Masculino Idioma: Espanhol Revista: Enferm. infecc. microbiol. clín. (Ed. impr.) Ano de publicação: 2024 Tipo de documento: Artigo Instituição/País de afiliação: Complejo Hospitalario Universitario de Santiago de Compostela/España / Hospital El Bierzo/España / Hospital Público da Mariña/España / Hospital Universitario Clinico San Cecilio/España
Buscar no Google
Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Plasma / Vírus da Hepatite B / Hepacivirus / Carga Viral / Reação em Cadeia da Polimerase em Tempo Real Limite: Feminino / Humanos / Masculino Idioma: Espanhol Revista: Enferm. infecc. microbiol. clín. (Ed. impr.) Ano de publicação: 2024 Tipo de documento: Artigo Instituição/País de afiliação: Complejo Hospitalario Universitario de Santiago de Compostela/España / Hospital El Bierzo/España / Hospital Público da Mariña/España / Hospital Universitario Clinico San Cecilio/España
...