Your browser doesn't support javascript.
loading
Infecciones de repetición en un paciente portador de un sistema de neuromodulación tras la picadura de insecto / Recurrent infection following an insect bite. In a patient with a neuromodulation system
Villanueva, V; Pérez, A; Asensio, J. M; Andrés, J. A. de.
Afiliação
  • Villanueva, V; Consorcio Hospital General Universitario de Valencia. Valencia. España
  • Pérez, A; Consorcio Hospital General Universitario de Valencia. Valencia. España
  • Asensio, J. M; Consorcio Hospital General Universitario de Valencia. Valencia. España
  • Andrés, J. A. de; Consorcio Hospital General Universitario de Valencia. Valencia. España
Rev. Soc. Esp. Dolor ; 13(5): 294-299, jun. 2006. ilus, tab
Artigo em Es | IBECS | ID: ibc-63966
Biblioteca responsável: ES15.1
Localização: ES15.1 - BNCS
RESUMEN
El desarrollo de la tecnología en las últimas décadas del siglo XX ha conllevado disponer de dispositivos, como los neuroestimuladores espinales, que han permitido un salto cualitativo muy importante en el tratamiento de pacientes con dolor severo y de difícil control. En general, las complicaciones que pueden surgir tras la colocación de un electrodo de estimulación de cordones posteriores son mínimas, pero se han descrito algunas de ellas, como son el desplazamiento del electrodo, la infección y la rotura del electrodo. Presentamos el caso de un paciente joven, ingeniero técnico agrícola, con antecedente de alergia a ácaros del polvo, que presentó tras la picadura de un insecto (Simulium Dam-nosum) en miembro superior derecho, un cuadro de shock séptico, con ingreso durante 48 horas en Reanimación. Durante la hospitalización presentó dolor neuropático severo con escasa respuesta a tratamiento convencional. Tres años y medio después de la picadura del insecto, fue remitido a la Unidad del Dolor de nuestro centro, donde se procedió a primer tiempo de implante de electrodo de estimulación de cordones posteriores, que hubo de ser retirado a los seis días por una infección del electrodo por Estafilococo Aureus. El paciente fue sometido a las pruebas epicutáneas con las sustancias habituales y con las sustancias procedentes de los componentes del neuroestimulador. Se descartó la posibilidad de alergia a alguno de los componentes del sistema implantable que fuera el responsable de una reacción inflamatoria y posterior sobreinfección del catéter. Es necesario destacar que la mejor manera de evitar las infecciones es extremar las medidas de asepsia y debemos valorar la realización de las pruebas de alergia en pacientes con historia de reacciones alérgicas o atopia que aseguren no causarán rechazo del sistema (AU)
ABSTRACT
Technological developments in the last decade of the 20th century have led to the design of devices such as spinal cord stimulators for the management of severe and intractable pain. Complications after the implantation of the electrodes are infrequent, but some as breakage, infection and displacement have been reported. The case of a young technical agricultural engineer with a medical history of allergy to acarus is described. He developed a septic shock following the sting of an insect (Simu-lium Damnasum) on the top right limb, being admitted to intensive care for 48 hours. During his hospital stay, he had severe neuropathic pain with a poor response to conventional treatment. Three and a half years after this event, the patient was sent to the Pain Management Unit, where the first stage of an electrode implantation for a spinal cord stimulator was carried out. The system was withdrawn after six days due to a Staphylococcus Aureus infection. A series of epicutaneous test for regular substances and for those from the spinal cord stimulator components were made. The likelihood of an allergy to some component of the implantable device, responsible for an inflammatory reaction and subsequent infection of the catheter, was ruled out. It is important to point out that careful asepsis is still the best means to avoid infections. In patients with a medical history of atopia or allergic reactions, allergic tests should be considered as a measure to prevent rejections of devices (AU)
Assuntos
Texto completo: Disponível Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Infecções Estafilocócicas / Estimulação Elétrica Nervosa Transcutânea / Mordeduras e Picadas de Insetos Limite: Humanos / Masculino Idioma: Espanhol Revista: Rev. Soc. Esp. Dolor Ano de publicação: 2006 Tipo de documento: Artigo Instituição/País de afiliação: Consorcio Hospital General Universitario de Valencia/España
Texto completo: Disponível Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Infecções Estafilocócicas / Estimulação Elétrica Nervosa Transcutânea / Mordeduras e Picadas de Insetos Limite: Humanos / Masculino Idioma: Espanhol Revista: Rev. Soc. Esp. Dolor Ano de publicação: 2006 Tipo de documento: Artigo Instituição/País de afiliação: Consorcio Hospital General Universitario de Valencia/España
...