Your browser doesn't support javascript.
loading
Prótesis metacarpofalángicas de carbón pirolítico. Seguimiento a medio plazo / Pyrolytic carbon metacarpophalangeal implants. Medium-term follow-up
León-Andrino, A. A; Olmos-Molpeceres, L; García-Fraile, R; Martín-Ferrero, M. A.
Afiliação
  • León-Andrino, A. A; Hospital Clínico Universitario. Valladolid. España
  • Olmos-Molpeceres, L; Hospital Clínico Universitario. Valladolid. España
  • García-Fraile, R; Hospital Clínico Universitario. Valladolid. España
  • Martín-Ferrero, M. A; Hospital Clínico Universitario. Valladolid. España
Rev. esp. cir. ortop. traumatol. (Ed. impr.) ; 52(3): 145-151, mayo 2008. ilus, tab
Artigo em Es | IBECS | ID: ibc-67092
Biblioteca responsável: ES15.1
Localização: ES15.1 - BNCS
RESUMEN
Objetivo. Evaluar a medio plazo en los pacientes con artroplastia metacarpofalángica de carbón pirolítico la disminución del dolor, el incremento del arco de movilidad, la funcionalidad de la mano, así como la incidencia y tipos de complicaciones. Valorar la disminución de la desviación cubital y el grado de satisfacción del paciente.Material y método. Estudio retrospectivo de 28 prótesis metacarpofalángicas de carbón pirolítico, en 16 pacientes en el Hospital Clínico Universitario de Valladolid por un mismo cirujano, con un seguimiento medio de 39 meses.Resultados. Disminución del dolor en 6,3 puntos. Incremento de 21,5° del arco de movilidad. Incremento del 23% de funcionalidad. Escasa incidencia de complicaciones intra y posquirúrgicas. La desviación cubital disminuyó en 10° y la satisfacción de los pacientes fue de 7,1 puntos.Conclusiones. Hemos observado a medio plazo una buenaresistencia y biocompatibilidad de la prótesis. El dolor disminuyó, así como aumentó el arco de movilidad posibilitando las actividades básicas de los pacientes. Las complicaciones intra y posquirúrgicas son escasas, y los pacientes se encuentran satisfechos. Estamos expectantes con la evolución de algunas imágenes osteolíticas periprotésicas pese a que no han evolucionado en el tiempo y son asintomáticas.Las prótesis que presentamos nos parecen hoy en día la mejor opción en patologías crónicas destructivas de las articulaciones metacarpofalángicas no demasiado evolucionadas, sobre todo en reumáticos jóvenes y en pacientes con artrosis (AU)
ABSTRACT
Purpose. To assess the medium-term effect of pyrolytic carbon metacarpophalangeal arthroplasty on pain relief, ROM increase and hand function, as well as the incidence and type of complications observed. We also set about evaluating the reduction on ulnar deviation and the patients’ degree of satisfaction.Materials and methods. This was a retrospective study of28 pyrolytic carbon metacarpophalangeal prostheses implanted into 16 patients at the Valladolid UniversityHospital by one single surgeon, with a mean follow-up of39 months.Results. Pain decreased by 6.3 points, ROM increased by21.5° and function improved by 23%. Low incidence ofintra– and postoperative complications. Ulnar deviationdecreased by 10°, while patient satisfaction stood at7.1 points.Conclusions. The prosthesis under study showed good medium-term levels of resistance and biocompatibility. Pain decreased and ROM increased, making it possible for patients to carry out their elementary activities. Intra–and postoperative complications were few and patients were satisfied. Periprosthetic osteolysis was observed in a few cases, but it has not got worse and has remained asymptomatic. The prosthesis presented hereby seem to us the best option available at present to address early to mid-stage chronic disease of the metacarpophalangeal joint, especially in young RA patients and in patients with OA (AU)
Assuntos
Buscar no Google
Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Artroplastia de Substituição / Articulação Metacarpofalângica Tipo de estudo: Estudo observacional / Fatores de risco Limite: Adulto / Idoso / Feminino / Humanos / Masculino Idioma: Espanhol Revista: Rev. esp. cir. ortop. traumatol. (Ed. impr.) Ano de publicação: 2008 Tipo de documento: Artigo Instituição/País de afiliação: Hospital Clínico Universitario/España
Buscar no Google
Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Artroplastia de Substituição / Articulação Metacarpofalângica Tipo de estudo: Estudo observacional / Fatores de risco Limite: Adulto / Idoso / Feminino / Humanos / Masculino Idioma: Espanhol Revista: Rev. esp. cir. ortop. traumatol. (Ed. impr.) Ano de publicação: 2008 Tipo de documento: Artigo Instituição/País de afiliação: Hospital Clínico Universitario/España
...