Resonance frequency analysis of dental implant stability during the healing period
Med. oral patol. oral cir. bucal (Internet)
; 13(4): 244-247, abr. 2008. ilus, tab
Artigo
em En
| IBECS
| ID: ibc-67379
Biblioteca responsável:
ES15.1
Localização: ES15.1 - BNCS
ABSTRACT
No disponible
ABSTRACT
Purpose:
The objective of the present study was to measure the implant stability quotient (ISQ) values during the osseointegration period, and determine the factors that affect implant stability. Materials andMethods:
To measure implant stability, resonance frequency analysis (RFA) was performed in 24 patients (12 women, 12 men) with a total 64 Defcon® implants (10 anterior maxilla, 12 posterior maxilla, 18 anterior mandible, 24 posterior mandible). Bone type was classified according to the Lekholm and Zarb index (52 type II bone, 12 type III). RFA was used for directmeasurement of implant stability on the day of implant placement and consecutively once a week for 8 weeks and at week 10.Results:
The mean ISQ of all measured implants was 62.6. The lowest mean stability measurement was at 4 weeks for all bone types (60.9). Gender was found to be significant (p<0.05); women showed higher implant stability than men. In relation to location within the dental arch, statistical analysis showed higher ISQ values for anterior implants than posterior fixtures (p<0.05) (AU)
Buscar no Google
Coleções:
Bases de dados nacionais
/
Espanha
Base de dados:
IBECS
Assunto principal:
Osseointegração
/
Implantação Dentária
Tipo de estudo:
Estudo diagnóstico
Limite:
Humanos
Idioma:
Inglês
Revista:
Med. oral patol. oral cir. bucal (Internet)
Ano de publicação:
2008
Tipo de documento:
Artigo
Instituição/País de afiliação:
Valencia University/Spain