Inducción de esputo en niños: desarrollo técnico / Sputum induction in children: technical development
Vizmanos Lamotte, G; Moreno Galdó, A; Cruz Carmona, M. J; Muñoz Gall, X; Gómez Olles, S; Mir Messa, I. de; Gartner, S; Martín de Vicente, C.
Afiliação
  • Vizmanos Lamotte, G; Hospital Nostra Senyora de Meritxell. Andorra
  • Moreno Galdó, A; Hospital Universitari Vall d’Hebron. Barcelona. España
  • Cruz Carmona, M. J; Hospital Universitari Vall d’Hebron. Barcelona. España
  • Muñoz Gall, X; Hospital Universitari Vall d’Hebron. Barcelona. España
  • Gómez Olles, S; Hospital Universitari Vall d’Hebron. Barcelona. España
  • Mir Messa, I. de; Hospital Universitari Vall d’Hebron. Barcelona. España
  • Gartner, S; Hospital Universitari Vall d’Hebron. Barcelona. España
  • Martín de Vicente, C; Hospital Universitari Vall d’Hebron. Barcelona. España
An. pediatr. (2003, Ed. impr.) ; 72(3): 199-204, mar. 2010. tab
Artigo em Espanhol | IBECS | ID: ibc-78514
Biblioteca responsável: ES1.1
Localização: BNCS
RESUMEN

Objetivos:

Comparar el rendimiento (total de muestras obtenidas) de nebulizadores ultrasónicos de flujo bajo y alto en la inducción de esputo en niños asmáticos, y valorar los efectos adversos asociados. Pacientes y

métodos:

Se nebulizó suero salino hipertónico a concentraciones crecientes (3%, 4%, 5%) utilizando nebulizadores ultrasónicos de bajo flujo (Omron NE-U07(R); flujo 1ml/min) y de alto flujo (Omron NE-U12(R); flujo 3 ml/min, y DeVilbiss Ultraneb 3000(R); flujo 2,5ml/min).

Resultados:

Se realizaron 49 inducciones en 49 pacientes entre 7 y 15 años de edad (en 15 niños se utilizó un nebulizador de bajo flujo y en 34 niños un nebulizador de alto flujo (Omron NEU12(R) 6 casos, DeVilbiss Ultraneb 3000(R) 28 casos). Se obtuvieron 37 muestras. Treinta y seis presentaban<20% de células escamosas y 26 tenían una viabilidad ≥60%. El rendimiento de la prueba fue mayor con los nebulizadores de alto flujo (85,3% de muestras), frente al 53% (p=0,04). El 69% de las muestras obtenidas con los nebulizadores de alto flujo fueron válidas, frente al 62,5% con el de bajo flujo (p=0,7). Con los nebulizadores de alto flujo disminuyó la incidencia de tos (17,6%, p=0,08) y de picor de ojos (0%, p=0,02), respecto al nebulizador de bajo flujo (47% y 20% respectivamente), aunque aumentó el sabor desagradable (82,3%, p<0,001) y la sialorrea (14,7%, p=0,3).

Conclusiones:

Con los nebulizadores ultrasónicos de alto flujo se consigue un mayor rendimiento de la técnica sin que se observe un aumento de efectos adversos significativos (AU)
ABSTRACT

Objective:

To compare low and high flow nebulizers performance (total of samples) and its side effects on sputum induction in asthmatic children. Patients and

methods:

Sputum induction was performed by inhalation of a hypertonic saline solution at increasing concentrations (3%, 4% and 5%) using low flow (OMRON NE-U07(R); flow rate 1ml/min), or high flow (OMRON NE-U12(R); flow rate 3ml/min, and DeVilbiss Ultraneb 3000(R); flow rate 2.5ml/min) ultrasonic nebulizers.

Results:

We performed 49 inductions in 49 patients from 7 to 15 years old (in 15 children we used a low flow nebulizer (Omron NE-U07(R)) and in 34 children a high flow nebulizer (OMRON NEU12(R), 6 patients, and DeVilbiss Ultraneb 3000(R), 28 patients). We obtained 37 samples of which 36 had less than 20% of squamous cells, and 26 had a viability ≥60%. The test performance was higher with high-flow nebulizers, obtaining 85.3% of samples compared to 53% (p=0.04). A total of 69% of samples obtained with the high flow nebulizer were valid, compared to 62.5% (p=0.7) with the low flow nebulizers. With high flow rate nebulizers the incidence of cough (17.6%, p=0.08) and itchy eyes (0%, p=0.02) decreased with the low flow nebulizer (47% and 20% respectively), but bad taste (82.3%, p <0.001) and salivation (14.7%, p=0.3) increased.

Conclusions:

With high flow rate ultrasonic nebulizers we obtain a higher performance of the technique without an increase in significant side effects (AU)
Assuntos
Buscar no Google
Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Asma / Escarro / Nebulizadores e Vaporizadores Tipo de estudo: Estudo observacional / Fatores de risco Limite: Adolescente / Criança / Feminino / Humanos / Masculino Idioma: Espanhol Revista: An. pediatr. (2003, Ed. impr.) Ano de publicação: 2010 Tipo de documento: Artigo Instituição/País de afiliação: Hospital Nostra Senyora de Meritxell/Andorra / Hospital Universitari Vall d’Hebron/España
Buscar no Google
Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Asma / Escarro / Nebulizadores e Vaporizadores Tipo de estudo: Estudo observacional / Fatores de risco Limite: Adolescente / Criança / Feminino / Humanos / Masculino Idioma: Espanhol Revista: An. pediatr. (2003, Ed. impr.) Ano de publicação: 2010 Tipo de documento: Artigo Instituição/País de afiliação: Hospital Nostra Senyora de Meritxell/Andorra / Hospital Universitari Vall d’Hebron/España
...