Your browser doesn't support javascript.
loading
Fiabilidad interobservador del test de movilidad pasiva accesoria intervertebral lumbar y su correlación con la galvanopalpación en sujetos sanos / Inter-observer reliability of the passive accessory intervertebral motion test and its correlation with the galvanic palpation in healthy subjects
Minaya Muñoz, F. J; Valera Garrido, F; Veiga Monasterioguren, X.
Afiliação
  • Minaya Muñoz, F. J; Hospital FREMAP-Majadahonda. Madrid. España
  • Valera Garrido, F; Hospital FREMAP-Majadahonda. Madrid. España
  • Veiga Monasterioguren, X; Hospital FREMAP-Majadahonda. Madrid. España
Rev. iberoam. fisioter. kinesiol. (Ed. impr.) ; 13(1): 4-9, ene.-jun. 2010. ilus, tab
Article em Es | IBECS | ID: ibc-79964
Biblioteca responsável: ES1.1
Localização: BNCS
RESUMEN
Introducción El diagnóstico de fisioterapia de las disfunciones vertebrales es fundamental para clasificar las alteraciones musculoesqueléticas. La evaluación pasiva de la cantidad y la calidad del movimiento en los diferentes segmentos vertebrales guía la toma de decisiones en relación con el tratamiento de fisioterapia. Los objetivos del presente estudio son determinar la fiabilidad interobservador del test de movilidad pasiva accesoria posteroanterior intervertebral unilateral lumbar como test indicado para identificar sujetos con disfunción articular y analizar la corriente galvánica como herramienta diagnóstica en la identificación de disfunción articular en la columna lumbar con dicho test ortopédico. Material y método Dos fisioterapeutas expertos en fisioterapia manual realizaron el test en una muestra de 30 sujetos asintomáticos en los niveles L1-L5 (lado derecho e izquierdo), realizándose un total de 300 pruebas. Se determinó que un nivel lumbar estaba en disfunción basándose en una sensación final anormal, la calidad de la resistencia anormal y la posible aparición de dolor asociado al movimiento. Para determinar la utilidad diagnóstica de la corriente galvánica, otros dos fisioterapeutas realizaron galvanopalpación consecutivamente al test de movilidad en las articulaciones interapofisarias lumbares de los mismos sujetos asintomáticos. Resultados En el test de movilidad, el porcentaje de acuerdo fue del 86,3%. El índice kappa (k) mostró un acuerdo moderado (k=0,5). El test fue más fiable en los niveles lumbares L3-L4 y L4-L5. En la galvanopalpación el porcentaje de acuerdo fue del 83%. El k mostró un acuerdo moderado en la identificación de disfunción articular (k=0,41). La sensibilidad fue alta en el nivel lumbar L3-L4 y L4-L5 y baja en L1-L2; la especificidad fue elevada (82,7–96,3%) en toda la columna lumbar. Conclusiones La fiabilidad interobservador del test de movilidad es moderada (k=0,5). La galvanopalpación identifica disfunciones articulares, pero en la columna lumbar alta la sensibilidad es baja (AU)
ABSTRACT
Introduction The physical therapy diagnosis of a vertebral dysfunction is essential in order to classify musculoskeletal diseases. Passive assessment of quantity and quality of movement on the different vertebral segments guides the decision-making process relative to manual therapy treatment. The aims of this present study have been to determine the interobserver reliability of passive accessory intervertebral postero-anterior unilateral lumbar motion test as a test to identify subjects with joint dysfunction, and to analyze galvanic current as a diagnostic tool to identify joint dysfunction in the lumbar spine with the motion test. Material and methods Two physiotherapists, experts in manual therapy, carried out the test in 30 asymptomatic subjects at L1 to L5 levels (right and left sides), performing a total of 300 tests. To determine the diagnostic value of galvanic current, two other physiotherapists performed galvanic palpation consecutively to the motion test in lumbar zygapophysial joints in the same asymptomatic subjects. Results Percentage agreement was 86.3% for the motion test. The Kappa index showed substantial agreement (according to Landis and Koch, 1977) (k=0.5). PA accessory motion test was more reliable to identify symptomatic spinal L4-L5 and L5-S1 level. Regarding galvanic palpation, the agreement percentage was 83%. Kappa coefficient (k) showed moderate agreement for identification of joint dysfunction (k=0.41). Sensitivity was high in the lumbar level L3-L4 and L4-L5 and was low in L1-L2 level; specificity was high (82.7–96.3%) throughout the lumbar spine. Conclusions Interobserver reliability of the passive motion test is moderate (k=0.5). Galvanic palpation identifies joint dysfunction, however sensitivity is low in the upper lumbar spine (AU)
Assuntos
Buscar no Google
Coleções: 06-national / ES Base de dados: IBECS Assunto principal: Palpação / Sensibilidade e Especificidade / Modalidades de Fisioterapia / Cinesiologia Aplicada / Disco Intervertebral / Deslocamento do Disco Intervertebral Tipo de estudo: Diagnostic_studies / Guideline Limite: Adult / Female / Humans / Male Idioma: Es Revista: Rev. iberoam. fisioter. kinesiol. (Ed. impr.) Ano de publicação: 2010 Tipo de documento: Article
Buscar no Google
Coleções: 06-national / ES Base de dados: IBECS Assunto principal: Palpação / Sensibilidade e Especificidade / Modalidades de Fisioterapia / Cinesiologia Aplicada / Disco Intervertebral / Deslocamento do Disco Intervertebral Tipo de estudo: Diagnostic_studies / Guideline Limite: Adult / Female / Humans / Male Idioma: Es Revista: Rev. iberoam. fisioter. kinesiol. (Ed. impr.) Ano de publicação: 2010 Tipo de documento: Article