Validación del Índice de Función Lagrimal para el diagnóstico del ojo seco / Tear Function Index Validation for Dry Eye Diagnosis
Vico, E; Benítez del Castillo, J. M; Giménez, R. A; Fernández, C; García Sánchez, J.
Afiliação
  • Vico, E; Hospital Clínico Universitario de San Carlos. Unidad de Superficie e Inflamación Ocular. Madrid. España
  • Benítez del Castillo, J. M; Hospital Clínico Universitario de San Carlos. Unidad de Superficie e Inflamación Ocular. Madrid. España
  • Giménez, R. A; Hospital Clínico Universitario de San Carlos. Unidad de Superficie e Inflamación Ocular. Madrid. España
  • Fernández, C; Hospital Clínico Universitario de San Carlos. Unidad de Superficie e Inflamación Ocular. Madrid. España
  • García Sánchez, J; Hospital Clínico Universitario de San Carlos. Unidad de Superficie e Inflamación Ocular. Madrid. España
Arch. Soc. Esp. Oftalmol ; 79(6): 265-272, jun. 2004. graf, ilus
Artigo em Espanhol | IBECS | ID: ibc-81422
Biblioteca responsável: ES1.1
Localização: BNCS
RESUMEN

Objetivo:

Desarrollar un método sencillo para valorar clínicamente la dinámica lagrimal y evaluar su poder diagnóstico en el ojo seco. Material y

métodos:

Se ha seleccionado una muestra de 85 pacientes en los que hemos considerado cada ojo por separado (170 ojos) de los que 102 tenían un Schirmer menor de 10 y sintomatología de ojo seco. A todos los sujetos se les ha calculado el Índice de Función Lagrimal (IFL) que se obtiene del cociente entre el valor del test de Schirmer y el aclaramiento lagrimal. Para ello se instiló una gota de un colirio que contenía Fluoresceína al 0,5% y oxibuprocaína al 0,4% y se esperó 5 minutos. A continuación se colocó una tira de Schirmer otros 5 minutos. Sobre la tira se procedió a la lectura del valor del test de Schirmer y del aclaramiento según una escala de diluciones de fluoresceína.

Resultados:

Calculando el punto de corte del IFL discriminativo de ojo seco, obtuvimos que un valor del mismo igual o menor a 74 es indicativo de tal enfermedad con una sensibilidad del 74% y una especificidad del 63%. Asímismo pudimos comprobar que no existe correlación entre el test de Schirmer y el aclaramiento lagrimal.

Conclusiones:

El IFL es un método rápido y sensible que permite la identificación práctica de los pacientes con ojo seco. La falta de correlación entre el test de Schirmer y el aclaramiento demuestra que miden dos aspectos distintos de la dinámica lagrimal(AU)
ABSTRACT

Purpose:

To develop a simple method for the clinical evaluation of tear dynamics and evaluate its usefulness in the diagnosis of dry eye syndrome.

Methods:

The study includes 170 eyes from 85 adults. 102 eyes had a Schirmers test value of less than 10 mm and subjective symptoms of dry eye. Tear function index (TFI) was calculated in all the cases using prepared drops with 0.5% fluorescein and 0.4% oxibuprocaína. Five minutes later a Schirmer strip was placed on the conjunctival fornix. Schirmers test and tear clearance were calculated after a further five minutes. Tear clearance was measured using a table of fluorescein concentrations. TFI is the quotient between the value of the Schirmers test and TCR.

Results:

The cutt-off value of TFI in dry eye is 74. At this point the sensitivity of this method is 74% and the specificity is 63%. The Schirmers test results did not correlate with the tear clearance results.

Conclusion:

TFI is a rapid and sensitive method of identification of subjects with dry eye. The lack of correlation between TFI and TCR is because these methods evaluate differents aspects of tear dynamics (AU)
Assuntos
Texto completo: Disponível Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Xeroftalmia / Aparelho Lacrimal / Obstrução dos Ductos Lacrimais Tipo de estudo: Estudo diagnóstico / Estudo prognóstico Limite: Humanos Idioma: Espanhol Revista: Arch. Soc. Esp. Oftalmol Ano de publicação: 2004 Tipo de documento: Artigo Instituição/País de afiliação: Hospital Clínico Universitario de San Carlos/España
Texto completo: Disponível Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Xeroftalmia / Aparelho Lacrimal / Obstrução dos Ductos Lacrimais Tipo de estudo: Estudo diagnóstico / Estudo prognóstico Limite: Humanos Idioma: Espanhol Revista: Arch. Soc. Esp. Oftalmol Ano de publicação: 2004 Tipo de documento: Artigo Instituição/País de afiliação: Hospital Clínico Universitario de San Carlos/España
...