Your browser doesn't support javascript.
loading
Intensa retención de 99mTc-MIBI en la fase tardía como causa de error diagnóstico en la gammagrafía combinada paratiroides-tiroides / High retention of 99mTc-MIBI in delayed phase as a pitfall in the combined parathyroid-thyroid scintigraphy
Verdú, J; Lizárraga, C; Clavel, J; Prata, I; Calbo, J; Pomares, F.
Afiliação
  • Verdú, J; Hospital Universitario de San Juan de Alicante. Alicante. España
  • Lizárraga, C; Hospital Universitario de San Juan de Alicante. Alicante. España
  • Clavel, J; Hospital Universitario de San Juan de Alicante. Alicante. España
  • Prata, I; Hospital Universitario de San Juan de Alicante. Alicante. España
  • Calbo, J; Hospital Universitario de San Juan de Alicante. Alicante. España
  • Pomares, F; Hospital Universitario de San Juan de Alicante. Alicante. España
Rev. esp. med. nucl. (Ed. impr.) ; 29(5): 251-253, sept.-oct. 2010. ilus
Article em Es | IBECS | ID: ibc-81876
Biblioteca responsável: ES1.1
Localização: BNCS
RESUMEN
La gammagrafía de paratiroides con 99mTc-sestaMIBI es muy sensible en el diagnóstico y localización del adenoma de paratiroides. Sin embargo, se pueden producir errores diagnósticos debido a la coexistencia de lesiones tiroideas captantes de MIBI o en pacientes con cirugía tiroidea previa. Para intentar detectar dichas alteraciones tiroideas se realiza una gammagrafía con 99mTc-pertecnetato comparativa el mismo día. Ocasionalmente, como en nuestro caso, la lesión paratiroidea puede presentar una captación inicial y retención tardía de MIBI lo suficientemente importantes como para ser visualizadas en la gammagrafía tiroidea realizada a continuación, dando la falsa apariencia de una lesión captante también de pertecnetato. Este hecho ha sido llamado «shine through». Para evitarlo se pueden realizar las gammagrafías paratiroidea y tiroidea en días distintos. A nosotros nos resultó también de gran utilidad la comparación con ecografía y la PAAF de la lesión con determinación de PTH y tiroglobulina en el líquido aspirado(AU)
ABSTRACT
Dual phase parathyroid scintigraphy with 99mTc-sestaMIBI is a very sensitive technique in the preoperative localization and diagnosis of parathyroid adenoma. However, pitfalls have been reported in patients with thyroid nodules with MIBI uptake or with previous thyroid surgery. To solve this problem, a thyroid scintigraphy with 99mTc-pertechnetate is usually performed following the parathyroid study. Occasionally, as in our patient the parathyroid lesion may show high MIBI uptake and delayed washout that interfere with the subsequent thyroid scintigraphy giving the false appearance of a pertechnetate avid lesion. This has been called the «shine through» effect. To avoid it, the parathyroid and thyroid scintigraphies can be performed on separate days. We have also found it useful to compare our results with that of ultrasound and fine needle aspiration puncture with measurement of the parathyroid hormone (PTH) and thyroglobulin in the aspirated material(AU)
Assuntos
Buscar no Google
Coleções: 06-national / ES Base de dados: IBECS Assunto principal: Doenças das Paratireoides / Glândulas Paratireoides / Tecnécio Tc 99m Sestamibi / Pertecnetato Tc 99m de Sódio / Erros de Diagnóstico Tipo de estudo: Diagnostic_studies / Etiology_studies Limite: Female / Humans Idioma: Es Revista: Rev. esp. med. nucl. (Ed. impr.) Ano de publicação: 2010 Tipo de documento: Article
Buscar no Google
Coleções: 06-national / ES Base de dados: IBECS Assunto principal: Doenças das Paratireoides / Glândulas Paratireoides / Tecnécio Tc 99m Sestamibi / Pertecnetato Tc 99m de Sódio / Erros de Diagnóstico Tipo de estudo: Diagnostic_studies / Etiology_studies Limite: Female / Humans Idioma: Es Revista: Rev. esp. med. nucl. (Ed. impr.) Ano de publicação: 2010 Tipo de documento: Article