Evaluación de un método inmunonefelométrico competitivo para la cuantificación de la homocisteína / Evaluation of a competitive immunonephelometric method for the measurement of homocysteine
Fernández Ramos, Ana María; Segovia Cuevas, María Jesús; Cobos Díaz, Andrés; Enguix Armada, Alfredo.
Afiliação
  • Fernández Ramos, Ana María; Hospital Virgen de la Victoria. Málaga. España
  • Segovia Cuevas, María Jesús; Hospital Virgen de la Victoria. Málaga. España
  • Cobos Díaz, Andrés; Hospital Virgen de la Victoria. Málaga. España
  • Enguix Armada, Alfredo; Hospital Virgen de la Victoria. Málaga. España
Rev. lab. clín ; 1(1): 13-16, mar. 2008. tab, ilus
Artigo em Espanhol | IBECS | ID: ibc-84419
Biblioteca responsável: ES1.1
Localização: BNCS
RESUMEN
Introducción y objetivos. La homocisteína se relaciona con enfermedad vascular, alteraciones del estado nutricional y detección de homocistinuria en neonatos, entre otras enfermedades. Debido a la importancia de su determinación, han aparecido diferentes métodos de cuantificación; el objeto de este trabajo es evaluar el método inmunonefelométrico del aparato BN II (Dade Behring). Material y método. Se realizó una comparación entre 2 métodos de cuantificación el inmunoanálisis competitivo (IMMULITE 2000, DPC) y el análisis nefelométrico (BN II, Dade Behring), para lo cual se compararon los resultados de 74 muestras, además de determinar la imprecisión intraserial, imprecisión interdiaria, el límite de detección, el límite de cuantificación y el valor crítico del método inmunonefelométrico del BN II de Dade Behring. Resultados. La comparación entre ambos métodos mostró una buena correlación entre el inmunoanálisis competitivo, IMMULITE 2000 de DPC y el análisis nefelométrico, BN II de Dade Behring (Y = 1,4825 + 0,8342X). El valor crítico obtenido fue de 5,46 mmol/l y el límite de detección, de 5,77 mmol/l. La imprecisión intraserial fue inferior al 5% (3,65-4,66%). Conclusiones. El análisis nefelométrico (BN II, Dade Behring) ha demostrado cumplir todos los requisitos técnicos necesarios para su validación como método para la determinación de la homocisteína(AU)
ABSTRACT
Introduction. The homocysteine is associated with vascular diseases, alterations in the nutritional states, homocystinuria detection in neonates, as well as other diseases. Due to the importance of its determination, different measurement methods have been developed. The aim of this work is to evaluate the imunonephelometric method used in the Dade Behring BN II Nephelometer system. Material and method. We present a comparison between 2

methods:

a competitive inmunoassay (IMMULITE 2000, DPC) and the nephelometric test (BN II, Dade Behring). For the determination of within batch and between-day imprecision, 74 samples were analysed and compared. Results. The detection and quantification limits, and the critical value of the inmunonephelometric method, were also determined. Both methods showed good correlations (Y = 1.4825 + 0.8342X). We also obtained a critical value of 5.46 mmol/L and the detection limit was 5.77 mmol/L. Within batch imprecision was below 5 % (3.65-4.66%). Conclusions. The nephelometric test (Dade Behring BN II System) has demonstrated to fulfill all the technical requirements needed for its validation as a method for the determination of homocysteine(AU)
Assuntos
Buscar no Google
Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Doenças Vasculares / Imunoensaio / Técnicas de Laboratório Clínico / Homocisteína / Nefelometria e Turbidimetria Tipo de estudo: Estudo diagnóstico Limite: Feminino / Humanos / Masculino Idioma: Espanhol Revista: Rev. lab. clín Ano de publicação: 2008 Tipo de documento: Artigo Instituição/País de afiliação: Hospital Virgen de la Victoria/España
Buscar no Google
Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Doenças Vasculares / Imunoensaio / Técnicas de Laboratório Clínico / Homocisteína / Nefelometria e Turbidimetria Tipo de estudo: Estudo diagnóstico Limite: Feminino / Humanos / Masculino Idioma: Espanhol Revista: Rev. lab. clín Ano de publicação: 2008 Tipo de documento: Artigo Instituição/País de afiliação: Hospital Virgen de la Victoria/España
...