Your browser doesn't support javascript.
loading
Complementariedad de la espectroscopía univóxel y la imágen de espectroscopía multivóxel obtenidas mediante bobina de cuadratura para la detección del carcinoma de próstata / Quadrature coils for magnetic resonance spectroscopy in the detection of prostate cancer: Single voxel acquisition does not improve the diagnostic accuracy of multivoxel images
Martínez-Bisbal, M. C; Martínez-Granados, B; Catalá-Gregori, A. I; Sánchez, J; Celda, B; Martí-Bonmatí, L.
Afiliação
  • Martínez-Bisbal, M. C; Universitat de Valencia. Valencia. España
  • Martínez-Granados, B; ISCIII. CIBER, Bioingeniería, Biomateriales y Nanomedicina. Madrid. España
  • Catalá-Gregori, A. I; ISCIII. CIBER, Bioingeniería, Biomateriales y Nanomedicina. Madrid. España
  • Sánchez, J; Hospital Universitario Dr. Peset. Valencia. España
  • Celda, B; Universitat de Valencia. Valencia. España
  • Martí-Bonmatí, L; Philips Cuidados de la Salud España. Madrid. España
Radiología (Madr., Ed. impr.) ; 53(1): 47-55, ene.-feb. 2011. tab, ilus
Artigo em Espanhol | IBECS | ID: ibc-86151
Biblioteca responsável: ES1.1
Localização: BNCS
RESUMEN
Objetivo. Demostrar la viabilidad de la bobina de cuadratura para la detección del cáncer de próstata mediante espectroscopía univóxel e imágen multivóxel. Material y métodos. Se evaluaron 23 pacientes con sospecha de carcinoma de próstata, con niveles del antígeno especifico de próstata superior a 4ng/ml, (media 12±8ng/ml), independientemente del tacto rectal, estudiados en un equipo de RM de 1,5T con la bobina de cuadratura. Se adquirieron imágenes potenciadas en T2 e imágenes de espectroscopía. También se adquirieron estudios univóxel en aquellas zonas donde la imágen T2 o la imágen multivóxel estaban alteradas. Se realizó un control metodológico de espectroscopía con una disolución patrón de citrato. Resultados. Con la imágen espectroscópica y un punto de corte [(Co+Cr)/Cit] de 1,40 en el vóxel único se alcanzan unos valores de sensibilidad del 92%, especificidad del 55%, predictivo negativo del 86% y predictivo positivo del 69%. Con un punto de corte de 0,75, la especificidad disminuye discretamente (45%). La relación [(Co+Cr)/Cit] calculada para el volumen único obtenido del área más anormal en el T2 y en los cortes de espectroscopía multivóxel no mostró diferencias significativas entre tejidos no tumorales y carcinomas (ANOVA, p=0,1), aunque se observó una clara tendencia a aumentar el cociente con la hiperplasia y la degeneración neoplásica. Conclusión. La bobina de cuadratura permite obtener imágen multivóxel y espectros univóxel con una calidad técnica y clínicamente aceptables. El empleo de la espectroscopía univóxel no mejora la rentabilidad diagnóstica de la espectroscopía multivóxel y la imágen T2(AU)
ABSTRACT
Objective. To determine the viability of quadrature coils for detecting prostate cancer using single voxel and multivoxel spectroscopy images. Material and methods. We used a quadrature coil on a 1.5T MR scanner to evaluate 23 patients with suspected prostate cancer and prostate specific antigen levels greater than 4ng/ml (mean 12±8ng/ml), independently of findings at digital rectal examination. We acquired T2-weighted images and MR spectroscopy images. We also acquired single voxel studies in areas in which the T2-weighted images or the multivoxel images were altered. We used a citrate solution to verify the spectroscopic calibration. Results. Using spectroscopy images and a (Co+Cr)/Cit cutoff of 1.40 in single voxel spectroscopy, we achieved a sensitivity of 92%, specificity of 55%, a negative predictive value of 86%, and a positive predictive value of 69%. Using a cutoff of 0.75 decreased specificity slightly (45%). The (Co+Cr)/Cit ratio calculated for the single volume obtained from the most abnormal area in the T2-weighted images and in the multivoxel spectroscopy slices was not significantly different between cancerous and non-cancerous tissues (ANOVA, p=0.1), although there was a clear trend toward increased coefficients with hyperplasia and neoplastic degeneration. Conclusion. The quadrature coil enables multivoxel and single voxel spectroscopic images of clinically and technically acceptable quality to be obtained. Using single voxel spectroscopy does not improve the diagnostic performance of multivoxel spectroscopy and T2-weighted images(AU)
Assuntos
Buscar no Google
Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Neoplasias da Próstata / Análise Espectral / Imageamento por Ressonância Magnética / Espectroscopia de Ressonância Magnética / Sensibilidade e Especificidade Tipo de estudo: Estudo diagnóstico / Estudo prognóstico Limite: Idoso / Humanos / Masculino Idioma: Espanhol Revista: Radiología (Madr., Ed. impr.) Ano de publicação: 2011 Tipo de documento: Artigo Instituição/País de afiliação: Hospital Universitario Dr. Peset/España / ISCIII/España / Philips Cuidados de la Salud España/España / Universitat de Valencia/España
Buscar no Google
Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Neoplasias da Próstata / Análise Espectral / Imageamento por Ressonância Magnética / Espectroscopia de Ressonância Magnética / Sensibilidade e Especificidade Tipo de estudo: Estudo diagnóstico / Estudo prognóstico Limite: Idoso / Humanos / Masculino Idioma: Espanhol Revista: Radiología (Madr., Ed. impr.) Ano de publicação: 2011 Tipo de documento: Artigo Instituição/País de afiliação: Hospital Universitario Dr. Peset/España / ISCIII/España / Philips Cuidados de la Salud España/España / Universitat de Valencia/España
...