Your browser doesn't support javascript.
loading
Trastornos de conducción auriculoventricular tras implantación de prótesis aórtica CoreValve ®. Papel predictivo de la ecocardiografía transesofágica / Atrioventricular conduction disturbances after CoreValve ® aortic prosthesis implantation. Predictive role of transesophageal echocardiography
Almería Valera, Carlos; Agustín Loeches, Alberto de; Hernández-Antolín, Rosa Ana; García Fernández, Eulogio; Pérez de Isla, Leopoldo; Fernández Pérez, Cristina; Macaya Miguel, Carlos; Zamorano Gómeza, José Luis.
Afiliação
  • Almería Valera, Carlos; Hospital Clínico San Carlos. Madrid. España
  • Agustín Loeches, Alberto de; Hospital Clínico San Carlos. Madrid. España
  • Hernández-Antolín, Rosa Ana; Hospital Clínico San Carlos. Madrid. España
  • García Fernández, Eulogio; Hospital Clínico San Carlos. Madrid. España
  • Pérez de Isla, Leopoldo; Hospital Clínico San Carlos. Madrid. España
  • Fernández Pérez, Cristina; Hospital Clínico San Carlos. Madrid. España
  • Macaya Miguel, Carlos; Hospital Clínico San Carlos. Madrid. España
  • Zamorano Gómeza, José Luis; Hospital Clínico San Carlos. Madrid. España
Rev. esp. cardiol. (Ed. impr.) ; 64(12): 1202-1206, dic. 2011. tab, ilus
Artigo em Espanhol | IBECS | ID: ibc-93628
Biblioteca responsável: ES1.1
Localização: BNCS
RESUMEN
Tras el implante de prótesis percutánea aórtica CoreValve®, pueden aparecer trastornos de conducción auriculoventricular que precisan marcapasos permanente (un 40-45% de los pacientes). El objetivo de nuestro estudio es detectar si alguna variable ecocardiográfica de 2 o 3 dimensiones podría predecir la aparición de trastornos de conducción auriculoventricular. Para ello se estudió en 26 pacientes consecutivos la relación de la prótesis con el septo interventricular; 12 pacientes (46,1%) presentaron trastornos de conducción auriculoventricular tras el procedimiento. Una penetración protésica en el tracto de salida del ventrículo izquierdo > 12 mm y una superficie de contacto del stent de la prótesis con el septo interventricular en diástole > 90% se asociaron fuertemente con la aparición de trastornos de conducción auriculoventricular (87,5%; p=0,034). La superficie de contacto del stent resultó ser el único predictor independiente de dicha complicación (odds ratio=1,12; intervalo de confianza del 95%, 1,01-1,25; p=0,03). Los resultados indican que la implantación más alta de las prótesis y la reducción de la longitud del stent podrían reducir la frecuencia de esta complicación (AU)
ABSTRACT
Atrioventricular conduction disorders can appear after the implantation of percutaneous aortic CoreValve® prostheses in patients requiring permanent pacemakers (40%-45% of these patients). The aim of our study was to detect if 2- or 3-dimensional echocardiographic variables could predict the appearance of atrioventricular conduction disorders. For this purpose, the relationship of the prosthesis with the interventricular septum was studied in 26 consecutive patients. Twelve patients (46.1%) developed atrioventricular conduction disorders. A prosthetic penetration >12 mm in the left ventricular outflow tract and a contact surface >90% between the interventricular septum and the stent of the prosthesis in diastole were strongly associated with the appearance of conduction disturbances (87.5%; P=.034). The percentage of the prosthetic stent in contact with the interventricular septum in end diastole was the only independent predictor of atrioventricular conduction disorders (odds ratio=1.12; 95% confidence interval, 1.01-1.25; P=.03). The results suggest that a higher implantation of the prosthesis and a reduced stent length might decrease the incidence of this complication (AU)
Assuntos
Buscar no Google
Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Marca-Passo Artificial / Próteses Valvulares Cardíacas / Stents / Ecocardiografia Transesofagiana / Sistema de Condução Cardíaco / Doenças das Valvas Cardíacas Tipo de estudo: Estudo de etiologia / Estudo prognóstico / Fatores de risco Limite: Feminino / Humanos / Masculino Idioma: Espanhol Revista: Rev. esp. cardiol. (Ed. impr.) Ano de publicação: 2011 Tipo de documento: Artigo Instituição/País de afiliação: Hospital Clínico San Carlos/España
Buscar no Google
Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Marca-Passo Artificial / Próteses Valvulares Cardíacas / Stents / Ecocardiografia Transesofagiana / Sistema de Condução Cardíaco / Doenças das Valvas Cardíacas Tipo de estudo: Estudo de etiologia / Estudo prognóstico / Fatores de risco Limite: Feminino / Humanos / Masculino Idioma: Espanhol Revista: Rev. esp. cardiol. (Ed. impr.) Ano de publicação: 2011 Tipo de documento: Artigo Instituição/País de afiliação: Hospital Clínico San Carlos/España
...