Your browser doesn't support javascript.
loading
Terapia de vacío como adyuvante para eluso de sustitutos dérmicos monocapa / Combined use of vacuum assited device and dermal monolayer substitutes
Martínez-Méndez, J. R; Leyva Rodríguez, F; Ramón Bitrián, S; Casado Pérez, C.
Afiliação
  • Martínez-Méndez, J. R; Hospital Universitario La Paz. Servicio de Cirugía Plástica y Quemados. Madrid. España
  • Leyva Rodríguez, F; Hospital Universitario La Paz. Servicio de Cirugía Plástica y Quemados. Madrid. España
  • Ramón Bitrián, S; Hospital Universitario La Paz. Servicio de Cirugía Plástica y Quemados. Madrid. España
  • Casado Pérez, C; Hospital Universitario La Paz. Servicio de Cirugía Plástica y Quemados. Madrid. España
Cir. plást. ibero-latinoam ; 36(4): 321-326, dic. 2010. tab
Artigo em Espanhol | IBECS | ID: ibc-96765
Biblioteca responsável: ES1.1
Localização: BNCS
RESUMEN
El método de elección para la cobertura de algunos defectos cutáneos es el autoinjerto de piel parcial; sin embargo, sufre retracciones que pueden adquirir gran relevancia sobre áreas especiales. Diferentes autores han intentado evitar estos déficits funcionales mediante la interposición de matrices de regeneración dérmica monocapa e injerto en un solo tiempo quirúrgico. Diseñamos un estudio para comparar la tasa de integración de los injertos sobre una matriz monocapa con y sin la aplicación de terapia de vacío tipo VAC® sobre ellos. Se aleatorizaron 20 pacientes con defectos cutáneos sobre áreas especiales en 2 grupos. Recogimos los datos epidemiológicos y la etiología del defecto (quemadura aguda, secuelas de quemadura o defectos secundarios a extracción de colgajo fasciocutáneo). En 10 casos (Grupo I) se aplicó matriz dérmica monocapa Matriderm ® más un injerto cutáneo de piel parcial, realizando un cambio de vendaje a los 7 días y luego cada 3-4 días hasta su estabilización. En otros 10 pacientes (Grupo II), tras realizar el mismo protocolo quirúrgico se aplicó VAC ® durante una semana y se cambió hasta la estabilización del injerto. La evaluación del prendimiento del injerto y su estabilidad la realizó un observador ciego. Se recogieron todas las complicaciones surgidas en el postoperatorio hasta 3 meses después de la estabilidad del injerto. Comprobamos la homogeneidad de ambos grupos para las variables epidemiológicas de los pacientes, así como para la etiología de los defectos. (..) (AU)
ABSTRACT
Split thickness autografts are the gold standard for wound coverage. However, scars and retractions are frequent after skin grafts, and would be severe over special regions. Different authors avoid these complications using a dermal substitute interposed between the wound and the skin graft in the first surgical time. A prospective study was designed to evaluate the split thickness skin graft uptake time over a monolayer matrix, with and without a vacuum assisted therapy device (VAC®). Twenty patients with a full thickness wound over a special region were randomized between 2 groups. Epidemiological data and wound ethology(acute burn, burn sequelae or donor site after a fasciocutaneous flap raised)were collected. Matriderm ® (mono layer dermal substitute) and a split thickness skin graft was applied over 10 cases (Group I). The dressing was changed after 7 days, and every 3-4 days until the skin graft was uptake and stable. Another 10 cases were treated with the same surgical strategy (Group II). After surgery, a vacuum assisted therapy device(VAC®) was applied until the graft was uptake. The skin graft evaluation was done by a blind observer. All complications were reported until 3months after the skin graft was stable. The homogeneity between groups was assessed. Averaged uptake time was 17, 6 ± 8 days, and the total complication rate was 20%. Statistically differences were not found between the 2 groups for the complication rate. The uptake time was 21,4 ± 9 days in the Group I and 13,9 ± 4 days in the Group II. These differences was statically significative. As a conclusion, the use of monolayer dermal substitutes is safe, with skin graft uptake rate of 85%. Time for skin graft uptake over a monolayer dermal matrix is shorter using a VAC ® device over the skin graft, with similar complication rate (AU)
Assuntos
Texto completo: Disponível Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Anormalidades da Pele / Queimaduras / Dispositivos para Expansão de Tecidos / Pele Artificial Tipo de estudo: Ensaio clínico controlado / Guia de prática clínica / Estudo observacional / Fatores de risco Limite: Humanos Idioma: Espanhol Revista: Cir. plást. ibero-latinoam Ano de publicação: 2010 Tipo de documento: Artigo Instituição/País de afiliação: Hospital Universitario La Paz/España
Texto completo: Disponível Coleções: Bases de dados nacionais / Espanha Base de dados: IBECS Assunto principal: Anormalidades da Pele / Queimaduras / Dispositivos para Expansão de Tecidos / Pele Artificial Tipo de estudo: Ensaio clínico controlado / Guia de prática clínica / Estudo observacional / Fatores de risco Limite: Humanos Idioma: Espanhol Revista: Cir. plást. ibero-latinoam Ano de publicação: 2010 Tipo de documento: Artigo Instituição/País de afiliação: Hospital Universitario La Paz/España
...